Plan Review Stops For Permit 22031179 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-03-25 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-25 |
Time |
14:23 |
Sent To |
|
|
Notes |
2022-03-25 14:23:25 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-09-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-09-08 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-09-08 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-24 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-24 |
Time |
11:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-11 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-11 |
Time |
15:45 |
Sent To |
|
|
Notes |
2022-08-11 15:46:48 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A SURVEY. | | | | 2) ADDRESS ON THE DRAWINGS NEEDS TO MATCH THE ADDRESS | | ON THE BUILDING PERMIT APPLICATION. (19 ST VS 19 PLACE) | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-24 |
Time |
14:54 |
Sent To |
|
|
Notes |
2022-05-24 16:39:45 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A SURVEY. | | | | 2) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE ROOFING SYSTEM. | | | | 3) ADDRESS ON THE DRAWINGS NEEDS TO MATCH THE ADDRESS | | ON THE BUILDING PERMIT APPLICATION. | | | | 4) DRAWING SP-1 SHOWS THE CODE VERSION USED FOR DESIGN | | AS 2017 FBC - SHOULD BE 2020 FBC | | | | 5) SITE PLAN SHOWS BUILDING SETBACK AT 3' 2" - THE | | BUILDING OVERHANG (PROJECTION) ON THAT SIDE WILL NEED | | TO BE A MINIMUM OF 2' FROM THE PROPERTY LINE AND BE | | FIRE RATED PER FBC TABLE R302.1 | | WITH A 1' 4" OVERHANG YOU ARE 1' 10" FROM THE PROPERTY | | LINE - MUST BE AT LEAST 2' FROM THE PROPERTY LINE. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-21 |
Time |
06:48 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-21 |
Time |
06:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-15 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-15 |
Time |
09:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-04-18 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-04-18 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-04-18 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-21 |
Time |
06:48 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-31 |
Time |
16:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-26 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-08-26 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-19 |
Time |
07:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-15 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-01 |
Time |
08:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-25 |
Time |
08:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-10-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-10-03 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-09-21 |
Time |
09:26 |
Sent To |
|
|
Notes |
2022-10-21 16:47:11 | RECEIPT MU-2022-044038 - $2457.58 PAID | 2022-09-21 09:27:03 | 9/21/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-24 |
Time |
16:23 |
Sent To |
|
|
Notes |
2022-05-24 16:24:18 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-02 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-02 |
Time |
12:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-12 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-08-12 |
Time |
06:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-08 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-08 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-09-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-01 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-01 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-12 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-12 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-04-04 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-04-04 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-11 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-11 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-24 |
Time |
16:23 |
Sent To |
|
|
Notes |
2022-05-24 16:23:33 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-09-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-09-08 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-09-08 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-08-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-11 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-11 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-24 |
Time |
16:49 |
Sent To |
|
|
Notes |
2022-04-08 14:44:52 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2022-09-02 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2022-09-02 |
Time |
15:38 |
Sent To |
|
|
Notes |
2022-09-02 16:07:47 | 9/2/22 - PASSED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE CORRECT THE INDICATED ZONING INFORMATION TO | | ?CP-SF11 ? COLEMAN PARK SINGLE FAMILY 11? IN THE | | TABULATION ON THE PROPOSED SITE PLAN (SHEET SP-1 / 1 OF | | 13). [SATISFIED] | | 2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE ?PROPOSED 1 | | STORY NEW RESIDENCE? MEETING THE MINIMUM REQUIRED SIDE | | SETBACK OF FIVE (5) FEET FROM BOTH SIDE PROPERTY LINES | | IN THE GRAPHIC AND TABULATION ON THE PROPOSED SITE PLAN | | (SHEET SP-1 / 1 OF 13), IN ACCORDANCE WITH THE CITY?S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | SUBSECTION 94-223(C)(3)(D). [SATISFIED] | | 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT | | HEIGHT INFORMATION FOR THE ?PROPOSED 1 STORY NEW | | RESIDENCE? ON BOTH THE PROPOSED SITE PLAN (SHEET SP-1 / | | 1 OF 13) AND ELEVATIONS (SHEET 5 OF 13). [SATISFIED] | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE WINDOWS | | RECESSED A MINIMUM OF TWO (2) INCHES FROM THE EXTERIOR | | FACE OF THE FA?ADE ON BOTH THE ELEVATIONS (SHEET 5 OF | | 13) AND PROPOSED FLOOR PLAN (SHEET 3 OF 13), IN | | ACCORDANCE WITH THE ZLDR SUBSECTION 94-222(H)(6). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE | | PERMIT) TO BE ADDRESSED: | | 1. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | | | | KEVIE DEFRANC | | PLANNER ? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2022-08-26 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2022-08-26 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2022-08-26 |
Time |
08:45 |
Sent To |
|
|
Notes |
2022-08-26 08:45:55 | 8/26/22 - FAILED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE CORRECT THE INDICATED ZONING INFORMATION TO | | ?CP-SF11 ? COLEMAN PARK SINGLE FAMILY 11? IN THE | | TABULATION ON THE PROPOSED SITE PLAN (SHEET SP-1 / 1 OF | | 13). [NOT SATISFIED] | | 2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE ?PROPOSED 1 | | STORY NEW RESIDENCE? MEETING THE MINIMUM REQUIRED SIDE | | SETBACK OF FIVE (5) FEET FROM BOTH SIDE PROPERTY LINES | | IN THE GRAPHIC AND TABULATION ON THE PROPOSED SITE PLAN | | (SHEET SP-1 / 1 OF 13), IN ACCORDANCE WITH THE CITY?S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | SUBSECTION 94-223(C)(3)(D). [SATISFIED] | | 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT | | HEIGHT INFORMATION FOR THE ?PROPOSED 1 STORY NEW | | RESIDENCE? ON BOTH THE PROPOSED SITE PLAN (SHEET SP-1 / | | 1 OF 13) AND ELEVATIONS (SHEET 5 OF 13). [SATISFIED] | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE WINDOWS | | RECESSED A MINIMUM OF TWO (2) INCHES FROM THE EXTERIOR | | FACE OF THE FA?ADE ON BOTH THE ELEVATIONS (SHEET 5 OF | | 13) AND PROPOSED FLOOR PLAN (SHEET 3 OF 13), IN | | ACCORDANCE WITH THE ZLDR SUBSECTION 94-222(H)(6). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE | | PERMIT) TO BE ADDRESSED: | | 1. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | | | | KEVIE DEFRANC | | PLANNER ? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-08-08 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2022-08-08 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2022-08-08 |
Time |
10:58 |
Sent To |
|
|
Notes |
2022-08-08 11:01:33 | 8/8/22 - FAILED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE CORRECT THE INDICATED ZONING INFORMATION TO | | ?CP-SF11 ? COLEMAN PARK SINGLE FAMILY 11? IN THE | | TABULATION ON THE PROPOSED SITE PLAN (SHEET SP-1 / 1 OF | | 13). [NOT SATISFIED] | | 2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE ?PROPOSED 1 | | STORY NEW RESIDENCE? MEETING THE MINIMUM REQUIRED SIDE | | SETBACK OF FIVE (5) FEET FROM BOTH SIDE PROPERTY LINES | | IN THE GRAPHIC AND TABULATION ON THE PROPOSED SITE PLAN | | (SHEET SP-1 / 1 OF 13), IN ACCORDANCE WITH THE CITY?S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | SUBSECTION 94-223(C)(3)(D). [SATISFIED] | | 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT | | HEIGHT INFORMATION FOR THE ?PROPOSED 1 STORY NEW | | RESIDENCE? ON BOTH THE PROPOSED SITE PLAN (SHEET SP-1 / | | 1 OF 13) AND ELEVATIONS (SHEET 5 OF 13). [SATISFIED] | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE WINDOWS | | RECESSED A MINIMUM OF TWO (2) INCHES FROM THE EXTERIOR | | FACE OF THE FA?ADE ON BOTH THE ELEVATIONS (SHEET 5 OF | | 13) AND PROPOSED FLOOR PLAN (SHEET 3 OF 13), IN | | ACCORDANCE WITH THE ZLDR SUBSECTION 94-222(H)(6). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE | | PERMIT) TO BE ADDRESSED: | | 1. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | | | | KEVIE DEFRANC | | PLANNER ? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-04-01 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2022-04-01 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2022-04-01 |
Time |
16:23 |
Sent To |
|
|
Notes |
2022-04-01 16:24:02 | 4/1/22 - FAILED | | | | REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE CORRECT THE INDICATED ZONING INFORMATION TO | | ?CP-SF11 ? COLEMAN PARK SINGLE FAMILY 11? IN THE | | TABULATION ON THE PROPOSED SITE PLAN (SHEET SP-1 / 1 OF | | 13). | | 2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE ?PROPOSED 1 | | STORY NEW RESIDENCE? MEETING THE MINIMUM REQUIRED SIDE | | SETBACK OF FIVE (5) FEET FROM BOTH SIDE PROPERTY LINES | | IN THE GRAPHIC AND TABULATION ON THE PROPOSED SITE PLAN | | (SHEET SP-1 / 1 OF 13), IN ACCORDANCE WITH THE CITY?S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR) | | SUBSECTION 94-223(C)(3)(D). | | 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT | | HEIGHT INFORMATION FOR THE ?PROPOSED 1 STORY NEW | | RESIDENCE? ON BOTH THE PROPOSED SITE PLAN (SHEET SP-1 / | | 1 OF 13) AND ELEVATIONS (SHEET 5 OF 13). | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE WINDOWS | | RECESSED A MINIMUM OF TWO (2) INCHES FROM THE EXTERIOR | | FACE OF THE FA?ADE ON BOTH THE ELEVATIONS (SHEET 5 OF | | 13) AND PROPOSED FLOOR PLAN (SHEET 3 OF 13), IN | | ACCORDANCE WITH THE ZLDR SUBSECTION 94-222(H)(6). | | | | ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE | | PERMIT) TO BE ADDRESSED: | | 1. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. | | | | | | KEVIE DEFRANC | | PLANNER ? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|