Plan Review Details - Permit 22031133
Plan Review Stops For Permit 22031133
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-09-18 Cont ID  
Sent By shill Date 2022-09-18 Time 19:19 Rev Time 0.00
Received By shill Date 2022-09-18 Time 19:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-18 Cont ID  
Sent By shill Date 2022-08-18 Time 07:52 Rev Time 0.00
Received By shill Date 2022-08-18 Time 07:52 Sent To  
Notes
2022-08-18 07:53:32[email protected]
 [email protected]
  
 1. THIS SUBMITTAL APPEARS TO HAVE MIXED UP PAPERWORK
 FOR 2 SEPERATE PROJECTS. PLEASE CORRECT AND RESUBMIT.
 FBC 107.2.1
  
 2. THIS PROJECT APPEARS TO REQUIRE ENGINEERED DESIGN
 PRESSURES. NOTHING IS MARKED ON THE SUBMITTED ENG
 EXPRESS TABLES. PLEASE CORRECT AND RESUBMIT, IF
 APPLICABLE. FBC 107.2.1.
 TO RETAIN THE DIGITAL SIGNATURE ON THE ENGINEERING
 UPLOADED, PLEASE UPLOAD A NEW DOCUMENT INDICATING THE
 DESIGN PRESSURES PROPOSED. ROOF HEIGHT, ZONE, SF AREA,
 NOT INDICATED SO DESIGN PRESSURES PROPOSED ARE NOT
 CLEAR.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By jbrooks Date 2022-06-06 Time 08:19 Rev Time 0.00
Received By jbrooks Date 2022-06-06 Time 08:19 Sent To  
Notes
2022-06-06 08:20:111ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. WIND LOAD CALCULATIONS PROVIDED SHOW A MEAN ROOF
 HEIGHT OF EQUAL TO OR LESS THAN 60'. THE BUILDING IS
 APPROXIMATELY 100' MRH. PLEASE REVISE AND PROVIDE A
 MEAN ROOF HEIGHT (MRH) ABOVE 60' WITH AN ORIGINAL
 DIGITAL SIGNATURE 3RD PARTY VALIDATED. 61G15-23
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-09-18 Cont ID  
Sent By shill Date 2022-09-18 Time 19:19 Rev Time 0.00
Received By shill Date 2022-09-02 Time 08:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-18 Cont ID  
Sent By shill Date 2022-08-18 Time 07:55 Rev Time 0.00
Received By shill Date 2022-07-29 Time 12:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-06 Cont ID  
Sent By jbrooks Date 2022-06-06 Time 08:20 Rev Time 0.00
Received By jbrooks Date 2022-05-13 Time 15:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-13 Cont ID  
Sent By lmarchan Date 2022-05-13 Time 10:38 Rev Time 0.00
Received By lmarchan Date 2022-05-04 Time 07:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-09-18 Cont ID  
Sent By shill Date 2022-09-18 Time 19:19 Rev Time 0.00
Received By shill Date 2022-09-18 Time 19:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-08-18 Cont ID  
Sent By shill Date 2022-08-18 Time 07:55 Rev Time 0.00
Received By shill Date 2022-08-18 Time 07:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By jbrooks Date 2022-06-06 Time 08:18 Rev Time 0.00
Received By jbrooks Date 2022-06-06 Time 08:18 Sent To  
Notes
2022-06-06 08:18:521ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 WIND LOAD CALCULATIONS ARE A COPY OF THE ORIGINAL PDF
 DIGITALLY SIGNED DOCUMENT.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved