Plan Review Details - Permit 22030667
Plan Review Stops For Permit 22030667
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By cpuell Date 2022-08-03 Time 14:01 Rev Time 0.00
Received By cpuell Date 2022-08-03 Time 14:01 Sent To  
Notes
2022-08-03 14:02:14PLEASE CONTACT [email protected], TO BE ASSIGNED A
 GENERIC PROPERTY CONTROL NUMBER FOR MCI METRO, ALSO
 PLEASE EMAIL A SITE PLAN SHOWING THE EXACT LOCATION OF
 THE WHERE THE WORK IS TO BE DONE. IN THE FUTURE PLEASE
 MAKE SURE THAT YOU COORDINATE WITH
 [email protected] OR CALL 561-805-6659 BEFORE
 APPLYING FOR A PERMIT TO BE ISSUED AN @ ADDRESS.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-08-16 Cont ID  
Sent By sberglun Date 2022-08-16 Time 10:38 Rev Time 0.00
Received By sberglun Date 2022-08-16 Time 10:38 Sent To  
Notes
2022-08-16 10:38:511) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS.
 INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE
 MATERIAL, AND DESCRIPTION ON BOTH PLAN VIEW AND PROFILE
 VIEW. CONTACT JANICE TARBILL, [email protected] FOR
 AS-BUILT INFORMATION. INCLUDE AS-BUILT INFORMATION IN
 YOUR RESUBMITTAL.
 2) PROPOSED BORE IS LOCATED OUTSIDE OF THE ROW AND RUNS
 THROUGH PRIVATE PROPERTY PER YOUR PLAN. THIS REQUIRES A
 UTILITY EASEMENT, OWNER?S CONSENT OR A REROUTE THROUGH
 THE PUBLIC ROW.
 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE
 REQUIRED PER CITY STANDARD, PARTIAL SIDEWALK FLAG
 REPLACEMNTS ARE NOT ACCEPTABLE. PLEASE USE CITY OF WEST
 PALM BEACH STANDARD DETAILS.
 SUZANNE BERGLUND
 [email protected]
 561-494-1075
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-01 Cont ID  
Sent By aoliver Date 2022-09-01 Time 08:45 Rev Time 0.00
Received By aoliver Date 2022-07-13 Time 18:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-01 Cont ID  
Sent By aoliver Date 2022-09-01 Time 08:45 Rev Time 0.00
Received By aoliver Date 2022-09-01 Time 08:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-31 Cont ID  
Sent By eschneid Date 2022-08-31 Time 14:24 Rev Time 0.50
Received By eschneid Date 2022-08-31 Time 14:04 Sent To  
Notes
2022-08-31 15:03:20INSUFFICIENT
  
 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED
 SURVEYOR, THAT SHOWS THE RIGHT-OF-WAY LINE, THE
 SIDEWALK, AND ANY TREES WITHIN THE RIGHT-OF-WAY ALONG
 THE ENTIRE FIBER CONDUIT PATH SO THAT STAFF CAN VERIFY
 THAT THE BORE, OPEN TRENCH AND ANY REQUIRED BORE PIT
 AND HANDHOLES ARE WITHIN THE RIGHT-OF-WAY AND NOT ON
 PRIVATE PROPERTY.
  
 2) THE ENGINEERING DRAWINGS SHOW THE BORE, BORE PIT
 03+60, AND HANDHOLE 05+91 ON PRIVATE PROPERTY WHICH IS
 ONLY PERMITTED IF IT IS WITHIN A GENERAL UTILITY
 EASEMENT. THE SURVEY REQUIRED BY COMMENT #1 NEEDS TO
 SHOW ANY EASEMENT. IF NOT EASEMENT IS SHOWN, THEN THE
 BORE AND BORE PIT MUST BE FULLY IN THE RIGHT-OF-WAY.
  
 3) THE CLOSEST EDGE OF THE EXCAVATION FOR BORE PIT
 03+60 MUST SHOW A DIMENSION OF AT LEAST THREE FEET FROM
 THE TRUNK OF THE ADJACENT PALM TREE. THE BORE MACHINE
 MAY NOT STAGE ADJACENT TO THE PALM TREE. THE PALM TREE
 MUST BE SHOWN ON THE PLANS.
  
 4) THE PALM BEACH COUNTY DETAILS MUST BE REMOVED AND
 REPLACED BY THE APPROPRIATE WEST PALM BEACH DETAILS.
  
 5) THE BORE DEPTH IS SUFFICIENT TO AVOID TREE ROOTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  