Plan Review Details - Permit 22030667
Plan Review Stops For Permit 22030667 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-08-03 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-08-03 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-08-03 |
Time |
14:01 |
Sent To |
|
|
Notes |
2022-08-03 14:02:14 | PLEASE CONTACT [email protected], TO BE ASSIGNED A | | GENERIC PROPERTY CONTROL NUMBER FOR MCI METRO, ALSO | | PLEASE EMAIL A SITE PLAN SHOWING THE EXACT LOCATION OF | | THE WHERE THE WORK IS TO BE DONE. IN THE FUTURE PLEASE | | MAKE SURE THAT YOU COORDINATE WITH | | [email protected] OR CALL 561-805-6659 BEFORE | | APPLYING FOR A PERMIT TO BE ISSUED AN @ ADDRESS. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-08-16 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-08-16 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-08-16 |
Time |
10:38 |
Sent To |
|
|
Notes |
2022-08-16 10:38:51 | 1) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS. | | INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE | | MATERIAL, AND DESCRIPTION ON BOTH PLAN VIEW AND PROFILE | | VIEW. CONTACT JANICE TARBILL, [email protected] FOR | | AS-BUILT INFORMATION. INCLUDE AS-BUILT INFORMATION IN | | YOUR RESUBMITTAL. | | 2) PROPOSED BORE IS LOCATED OUTSIDE OF THE ROW AND RUNS | | THROUGH PRIVATE PROPERTY PER YOUR PLAN. THIS REQUIRES A | | UTILITY EASEMENT, OWNER?S CONSENT OR A REROUTE THROUGH | | THE PUBLIC ROW. | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | REQUIRED PER CITY STANDARD, PARTIAL SIDEWALK FLAG | | REPLACEMNTS ARE NOT ACCEPTABLE. PLEASE USE CITY OF WEST | | PALM BEACH STANDARD DETAILS. | | SUZANNE BERGLUND | | [email protected] | | 561-494-1075 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-09-01 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-09-01 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-07-13 |
Time |
18:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-09-01 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-09-01 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-09-01 |
Time |
08:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-08-31 |
Time |
14:24 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-08-31 |
Time |
14:04 |
Sent To |
|
|
Notes |
2022-08-31 15:03:20 | INSUFFICIENT | | | | 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED | | SURVEYOR, THAT SHOWS THE RIGHT-OF-WAY LINE, THE | | SIDEWALK, AND ANY TREES WITHIN THE RIGHT-OF-WAY ALONG | | THE ENTIRE FIBER CONDUIT PATH SO THAT STAFF CAN VERIFY | | THAT THE BORE, OPEN TRENCH AND ANY REQUIRED BORE PIT | | AND HANDHOLES ARE WITHIN THE RIGHT-OF-WAY AND NOT ON | | PRIVATE PROPERTY. | | | | 2) THE ENGINEERING DRAWINGS SHOW THE BORE, BORE PIT | | 03+60, AND HANDHOLE 05+91 ON PRIVATE PROPERTY WHICH IS | | ONLY PERMITTED IF IT IS WITHIN A GENERAL UTILITY | | EASEMENT. THE SURVEY REQUIRED BY COMMENT #1 NEEDS TO | | SHOW ANY EASEMENT. IF NOT EASEMENT IS SHOWN, THEN THE | | BORE AND BORE PIT MUST BE FULLY IN THE RIGHT-OF-WAY. | | | | 3) THE CLOSEST EDGE OF THE EXCAVATION FOR BORE PIT | | 03+60 MUST SHOW A DIMENSION OF AT LEAST THREE FEET FROM | | THE TRUNK OF THE ADJACENT PALM TREE. THE BORE MACHINE | | MAY NOT STAGE ADJACENT TO THE PALM TREE. THE PALM TREE | | MUST BE SHOWN ON THE PLANS. | | | | 4) THE PALM BEACH COUNTY DETAILS MUST BE REMOVED AND | | REPLACED BY THE APPROPRIATE WEST PALM BEACH DETAILS. | | | | 5) THE BORE DEPTH IS SUFFICIENT TO AVOID TREE ROOTS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | |
|
|
|