Plan Review Details - Permit 22030663
Plan Review Stops For Permit 22030663
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2022-04-21 Cont ID  
Sent By rmcphers Date 2022-04-21 Time 14:42 Rev Time 0.00
Received By rmcphers Date 2022-04-21 Time 14:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-04-21 Cont ID  
Sent By mpeterso Date 2022-04-21 Time 13:59 Rev Time 0.00
Received By mpeterso Date 2022-04-21 Time 13:59 Sent To  
Notes
2022-04-21 14:01:21ELECTRIC REVIEW FAILED
  
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR,
 OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR OR
 PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-04-13 Cont ID  
Sent By pleduc Date 2022-04-13 Time   Rev Time 0.00
Received By pleduc Date 2022-04-12 Time 12:07 Sent To  
Notes
2022-04-13 16:19:57THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE ARE INDICATIONS OF PROVIDING FOR 2-WAY
 COMMUNICATIONS IN "AREAS OF REFUGE".
  
 AREAS OF REFUGE DOES NOT AAPPEAR TO BE REQUIRED WITHIN
 THIS OCCUPANCY DUE TO THE INSTALLATION OF A FIRE
 SPRINKLER SYSTEM.
  
 THE FLORIDA BUILDING CODE HAS AN EXEMPTION DUE TO FIRE
 SPRINKLER INSTALLTION AND OTHER FEATURES OF THE EIT
 ACCESS.
  
 THE FLORIDA LIFE SAFETY CODE REFERENCES AREAS OF REFUGE
 FOR ACCESSIBLE MEANS OF EGRESS. ACCESSIBLE MEANS OF
 EGRESS IS NOT APPLICABLE DUE TO THE BUILDING CODE
 EXEMPTION.
  
 FOR CLARIFICATIONS AND FOR THE OFFICIAL RECORD, PLEASE
 PROVIDE A DETAILED NARRATIVE OF REVIEW OF THE BUILDING
 CODE AND IF THE INTENT IS TO INSTALL THIS 2-WAY SYSTEM
 AS A REQUEST AND NOT A REQUIREMENT.
  
 SHOULD THE REVIEW FIND IT IS NOT REQUIRED AND YOU WISH
 TO WITHDRAWL THIS PERMIT, PLEASE PROVIDE THE APPLICABLE
 WRITTEN RESPONSE.
  
  
 1A) IF THE INTENT IS TO PROVIDE THIS 2-WAY SYSTEM EVEN
 IF EXEMPTED BY THE BUILDING CODE, PLEASE MOVE THE
 COMMUNICATION METHOD OUT OF THE INDICATED POSTION BY
 THE ELEVLATORS TO WITHIN THE EXIT STAIRWELL AT THE
 LANDING.
  
  
 1B) THERE IS NO COMMAND CENTER/ROOM FOR THIS APRTMENT
 OCCUPANCY, SO PLEASE PROVIDE THE PROPOSED 24 HOUR
 EMERGECY CENTRAL CONTROL POINT. IT CAN NOT BE TO 911.
  
  
  
 1C) THE 2-WAY CALL BOX DOES NOT APPEAR TO BE REQUIRED
 ON THE 1ST FLOOR WHERE ACCESSIBLE EGRESS IS AVAILABLE
 WITHOUT RESTRICTION.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH CODE
 REFERENCES.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-21 Cont ID  
Sent By rmcphers Date 2022-04-21 Time 14:43 Rev Time 0.00
Received By rmcphers Date 2022-03-30 Time 11:26 Sent To  
Notes
***NONE***