Plan Review Stops For Permit 22030290 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-07-15 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-07-15 |
Time |
16:20 |
Sent To |
|
|
Notes |
2022-07-15 16:21:37 | APPLICANT UPLOADED NEW PLANS AND APPLICATION FORM 1401 | | ELIZABETH AVE |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-05-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-05-07 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-05-07 |
Time |
09:07 |
Sent To |
|
|
Notes |
2022-05-07 09:16:48 | INCONSISTENCIES WITH THE APPLICATION FORM AND THE | | PLANS, PLANS LIST 1501 ELIZABETH ST APPLICATION FORM | | LIST 1503 ELIZABETH ST. PLEASE CONFIRM THE AREA WHERE | | THE WORK IS TO BE DONE. PLEASE RESPOND TO | | [email protected] OR CALL 561-805-6659. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-25 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-25 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-02 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-02 |
Time |
10:59 |
Sent To |
|
|
Notes |
2022-08-02 11:00:23 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-05 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-05 |
Time |
15:30 |
Sent To |
|
|
Notes |
2022-05-05 15:31:38 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-09-16 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-25 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-25 |
Time |
09:35 |
Sent To |
|
|
Notes |
2022-08-25 09:41:05 | CREATING 2 UNITS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW STAIR HAND RAIL EXTENSION AT THE BOTTOM | | OF THE STAIRS TO SLOPE PER FBC 1014.6 HANDRAIL | | EXTENSIONS. | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) | | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE | | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. | | | | 2) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET PAPER | | DISPENSER DIMENSIONS FROM THE FRONT OF THE TOILET TO | | THE CENTER OF THE TOILET PAPER DISPENSER - FBC A 604.7 | | DISPENSERS. | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. | | | | 3) COMMENT RESPONSE SHOWS THE CORRECTION - PLEASE SHOW | | ON THE DRAWINGS - - PLEASE SHOW THE RAMP EDGE | | PROTECTION (SHOW THE GUARD RAIL BOTTOM RAIL WITHIN 4" | | OF THE RAMP) FBC A 405.9 EDGE PROTECTION. | | EDGE PROTECTION COMPLYING WITH 405.9.1 OR 405.9.2 SHALL | | BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE | | OF RAMP LANDINGS. 405.9.2CURB OR BARRIER. | | A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE | | PASSAGE OF A 4 INCH (100 MM) DIAMETER SPHERE, WHERE ANY | | PORTION OF THE SPHERE IS WITHIN 4 INCHES (100 MM) OF | | THE FINISH FLOOR OR GROUND SURFACE. | | | | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR STOREFRONT WINDOWS | | AND DOORS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED | | AND MARKED APPROVED BY THE DESIGNER OF RECORD FBC WPB | | 107.3.4 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-02 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-02 |
Time |
10:28 |
Sent To |
|
|
Notes |
2022-08-02 10:59:10 | CREATING 2 UNITS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW STAIR HAND RAIL EXTENSION AT THE BOTTOM | | OF THE STAIRS TO SLOPE PER FBC 1014.6 HANDRAIL | | EXTENSIONS. | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) | | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE | | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. | | | | 2) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | "REFLECTIVE SURFACE" WHEN SHOWING THE DIMENSION FROM | | THE FLOOR TO THE BOTTOM OF THE MIRROR - FBC A 603.3 | | MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 3) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET PAPER | | DISPENSER DIMENSIONS FROM THE FRONT OF THE TOILET AND | | HEIGHT FROM THE FLOOR - FBC A 604.7 DISPENSERS. | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL | | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES | | NOT ALLOW CONTINUOUS PAPER FLOW. | | | | 4) PLEASE SHOW THE RAMP EDGE PROTECTION (SHOW THE GUARD | | RAIL BOTTOM RAIL WITHIN 4" OF THE RAMP) FBC A 405.9 | | EDGE PROTECTION. | | EDGE PROTECTION COMPLYING WITH 405.9.1 OR 405.9.2 SHALL | | BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE | | OF RAMP LANDINGS. 405.9.2CURB OR BARRIER. | | A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE | | PASSAGE OF A 4 INCH (100 MM) DIAMETER SPHERE, WHERE ANY | | PORTION OF THE SPHERE IS WITHIN 4 INCHES (100 MM) OF | | THE FINISH FLOOR OR GROUND SURFACE. | | | | 5) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR STOREFRONT WINDOWS | | AND DOORS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED | | AND MARKED APPROVED BY THE DESIGNER OF RECORD FBC WPB | | 107.3.4 | | | | 6) CANNOT REUSE STOREFRONT WINDOWS UNLESS YOU HAVE A | | CURRENT PRODUCT APPROVAL FOR THEM - FBC EXISTING 707.4 | | REPLACEMENT OF WINDOWS AND DOORS. | | THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS, | | SKYLIGHTS, AND OPERATIVE AND INOPERATIVE WINDOWS SHALL | | BE DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 7) ELEVATION CERTIFICATE PROVIDED IS INCORRECT - PALM | | BEACH COUNTY FLOOD MAP SHOWS BUILDING IN A FLOOD ZONE | | (AE 12.10) - NFIP - JOB IS A SUBSTANTIAL IMPROVEMENT | | JOB VALUE + 5 YEAR ACCUMULATION = 1,015,272.00 - | | BUILDING VALUE = 1,355,080.00 - THE BUILDING LOWEST | | FLOOR ELEVATION NEEDS TO BE AT 14.10 NAVD - PLEASE | | PROVIDE AN ELEVATION CERTIFICATE TO VERIFY THE LOWEST | | FLOOR ELEVATION - ORDINANCE NO. 4729-17 SEC. 18-35 (A) | | AND (B) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-05 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-05 |
Time |
15:31 |
Sent To |
|
|
Notes |
2022-05-05 15:41:39 | CREATING 2 UNITS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE MOP SINK WALLS TO COMPLY WITH FBC | | 1210.2.2 WALLS AND PARTITIONS. | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, | | | | 2) PLEASE SHOW STAIR HAND RAIL HEIGHT PER FBC 1014.2 | | HEIGHT. | | HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, OR | | FINISH SURFACE OF RAMP SLOPE, SHALL BE UNIFORM, NOT | | LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 | | INCHES (965 MM). | | | | 3) PLEASE SHOW STAIR HAND RAIL EXTENSION AT THE BOTTOM | | OF THE STAIRS TO SLOPE PER FBC 1014.6 HANDRAIL | | EXTENSIONS. | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) | | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE | | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. | | | | 4) PLEASE SHOW THE STAIR RISER HEIGHT AND TREAD DEPTHS | | TO COMPLY WITH FBC 1011.5.2 RISER HEIGHT AND TREAD | | DEPTH. | | STAIR RISER HEIGHTS SHALL BE 7 INCHES (178 MM) MAXIMUM | | AND 4 INCHES (102 MM) MINIMUM. THE RISER HEIGHT SHALL | | BE MEASURED VERTICALLY BETWEEN THE NOSINGS OF ADJACENT | | TREADS. RECTANGULAR TREAD DEPTHS SHALL BE 11 INCHES | | (279 MM) MINIMUM MEASURED HORIZONTALLY BETWEEN THE | | VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT | | TREADS AND AT A RIGHT ANGLE TO THE TREAD?S NOSING. | | | | 5) PLEASE SHOW THAT STAIR HAND RAILS ARE REQUIRED ON | | BOTH SIDES PER FBC 1011.11 HANDRAILS. | | FLIGHTS OF STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE | | AND SHALL COMPLY WITH SECTION 1014. | | | | 6) PLEASE SHOW THE STAIR LANDINGS SIZES PER FBC 1011.6 | | | | 7) PLEASE SHOW THE STAIR AND RAMP WIDTHS FBC 1005 - - | | FBC 1012.5.1 | | | | 8) PLEASE SHOW THAT HAND RAILS ARE REQUIRED ON BOTH | | SIDES OF THE RAMP - FBC 1012.8 HANDRAILS. | | RAMPS WITH A RISE GREATER THAN 6 INCHES (152 MM) SHALL | | HAVE HANDRAILS ON BOTH SIDES. | | | | 9) PLEASE SHOW THE RAMP LANDING SIZES - FBC A | | | | 10) PLEASE SHOW THE RAMP SLOPE - FBC A | | | | 11) PLEASE SHOW THE RAMP HAND RAIL HEIGHT - FBC A | | | | 12) PLEASE SHOW THE ACCESSIBLE DOOR WIDTHS - FBC A | | | | 13) BUILDING ADDRESS APPEARS TO BE INCORRECT ON THE | | BUILDING PERMIT APPLICATION AND THE DRAWINGS - PLEASE | | CORRECT. | | | | 14) PLEASE SHOW THE ACCESSIBLE RESTROOM DIMENSION | | DETAILS FOR THE GRAB BAR SIZES AND LOCATIONS, MIRROR, | | TOILET PAPER HOLDER, FIXTURE CLEAR FLOOR SPACE ETC PER | | FBC A CHAPTER 6 | | | | 15) PLEASE SHOW THE ACCESSIBLE ROUTE TO UNIT 100A - FBC | | A 206.4 ENTRANCES. | | ENTRANCES SHALL BE PROVIDED IN ACCORDANCE WITH 206.4. | | ENTRANCE DOORS, DOORWAYS, AND GATES SHALL COMPLY WITH | | 404 AND SHALL BE ON AN ACCESSIBLE ROUTE COMPLYING WITH | | 402. | | | | 16) DRAWING S0.01 SHOWS WIND SPEED USED FOR WIND DESIGN | | AS 169MPH - WIND DESIGN SPEED SHOULD BE 170MPH PER FBC | | WPB SECTION 120 | | | | 17) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR STOREFRONT WINDOWS | | AND DOORS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED | | AND MARKED APPROVED BY THE DESIGNER OF RECORD FBC WPB | | 107.3.4 | | | | 18) CANNOT REUSE STOREFRONT WINDOWS UNLESS YOU HAVE A | | CURRENT PRODUCT APPROVAL FOR THEM - FBC EXISTING 707.4 | | REPLACEMENT OF WINDOWS AND DOORS. | | THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS, | | SKYLIGHTS, AND OPERATIVE AND INOPERATIVE WINDOWS SHALL | | BE DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 19) NFIP - JOB IS A SUBSTANTIAL IMPROVEMENT JOB VALUE + | | 5 YEAR ACCUMULATION = 1,015,272.00 - BUILDING VALUE = | | 1,355,080.00 - THE BUILDING LOWEST FLOOR ELEVATION | | NEEDS TO BE AT 14.10 NAVD - PLEASE PROVIDE AN ELEVATION | | CERTIFICATE TO VERIFY THE LOWEST FLOOR ELEVATION - | | ORDINANCE NO. 4729-17 SEC. 18-35 (A) AND (B) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-27 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-27 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-05-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-05-06 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-05-06 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-09-07 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-09-07 10:21:49 | FIRE PROVISO COMMENTS: | | | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL REMAIN OPERATIONAL DURING ALL PHASES OF | | DEMOLITION AND CONSTRUCTION. | | | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL BE PROTECTED FROM DAMAGE DURING ALL PHASES | | OF DEMOLITION AND CONSTRUCTION. | | | | ANY AND ALL WORK ON ANY LIFE SAFETY SYSTEM (FIRE | | SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED UNDER | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | C. WALKER | | | | 561-804-4762 | | | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-07-15 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-07-15 11:00:59 | FIRE PROVISO COMMENTS: | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL REMAIN OPERATIONAL DURING ALL PHASES OF | | DEMOLITION AND CONSTRUCTION. | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL BE PROTECTED FROM DAMAGE DURING ALL PHASES | | OF DEMOLITION AND CONSTRUCTION. | | ANY AND ALL WORK ON ANY LIFE SAFETY SYSTEM (FIRE | | SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED UNDER | | SEPARATE PERMITS AND SHOP DRAWINGS. | | C. WALKER | | 561-804-4762 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-03-28 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-03-28 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-03-28 11:06:17 | FIRE COMMENTS: | | RETAIL SPACE 100B, MERCANTILE OCCUPANCY, | | THE LIFE SAFETY PLAN INDICATES A SINGLE EXIT WITH A | | DIRECT TRAVEL DISTANCE OF 74? 4?. THERE IS NO FURNITURE | | PLAN INCLUDED IN THE SUBMITTALS, WHICH CAN CHANGE THE | | DIRECTION OF TRAVEL THAT CAN EXCEED THE REQUIRED 75? | | TRAVEL DISTANCE AS REQUIRED IN NFPA 101 36.2.4.3 | | BOTH RETAIL SPACES 100A AND 100B ARE REQUIRED TO HAVE | | PORTABLE FIRE EXTINGUISHERS PROVIDED. NFPA 101 36.3.5.3 | | FIRE REVIEW CONDUCTED BY, | | C. R. WALKER, SENIOR FIRE INSPECTOR | | 561-804-4762 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-09-06 |
Time |
07:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-08-29 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-12 |
Time |
09:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-02 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-14 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-05-07 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-28 |
Time |
05:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-10-11 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-10-11 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-08-02 |
Time |
11:38 |
Sent To |
|
|
Notes |
2022-10-11 07:55:22 | RECEIPT MU-2022-045426 - $26,549.06 PAID | 2022-08-02 11:38:33 | 8/2/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-05 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-05 |
Time |
17:19 |
Sent To |
|
|
Notes |
2022-05-05 17:21:16 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-07-26 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-07-26 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-07-26 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-02 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-02 |
Time |
17:45 |
Sent To |
|
|
Notes |
2022-05-02 17:45:19 | 1ST REVIEW FMC | | PERMIT: 22030290 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) IS THIS A CHANGE OF USE? | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC 101.5.1.1.2 | | | | 3) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON | | FMC 403.3.1.1 3RD SENTENCE TELLS US TO USE TABLE | | 403.3.1.1 TO FIND THE OCCUPANT COUNT. WE CANNOT USE THE | | EGRESS OCCUPANT COUNTY. | | | | 4) PLEASE SHOW THE ROOF ACCESS. FMC 306.5 | | | | 5) WHY IS THE EXHAUST OF 2 SEPARATE TENANT SPACES BEING | | SHARED? FMC 501.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-25 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-25 |
Time |
09:45 |
Sent To |
|
|
Notes |
2022-08-25 09:45:36 | JOB IS A SUBSTANTIAL IMPROVEMENT JOB VALUE + 5 YEAR | | ACCUMULATION = 1,015,272.00 - BUILDING VALUE = | | 1,355,080.00 - THE BUILDING LOWEST FLOOR ELEVATION | | NEEDS TO BE AT 14.10 NAVD - PLEASE PROVIDE AN ELEVATION | | CERTIFICATE TO VERIFY THE LOWEST FLOOR ELEVATION - | | ORDINANCE NO. 4729-17 SEC. 18-35 (A) AND (B) | | | | AE 12.10 | | | | ELEVATION CERTIFICATE SHOWS LOWEST FLOOR AT 16.30 NAVD |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-07-15 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-07-15 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-04-26 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-04-26 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-04-26 |
Time |
10:36 |
Sent To |
|
|
Notes |
2022-04-26 10:44:57 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. PAGE P2.1 - V7 FPC 410.3 - A HIGH/LOW DRINKING | | FOUNTAIN IS REQUIRED. | | | | 2. PAGE P0.1 - 2020 FPC - 607.1.1 TEMPERATURE LIMITING | | MEANS - THE THERMOSTAT CONTROL ON THE WATER HEATER | | CANNOT BE THE LIMITING DEVICE FOR HOT WATER DELIVERY. | | PLEASE PROVIDE A DETAIL FOR A LIMITING DEVICE FOR THE | | PURPOSE OF HOT WATER DELIVERY. THIS WOULD BE IN | | ADDITION TO THE REQUIREMENTS FOR TEMPERED WATER FOR | | PUBLIC HAND-WASHING 607.1.2/419.5. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-09-16 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-25 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-25 |
Time |
09:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-07-15 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-07-15 |
Time |
13:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-05 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-05 |
Time |
17:25 |
Sent To |
|
|
Notes |
2022-05-02 17:50:51 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-08-25 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-08-25 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-07-28 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-07-28 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-07-28 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-04-05 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-04-05 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|