Plan Review Details - Permit 22030140
Plan Review Stops For Permit 22030140 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2022-03-23 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-03-23 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-23 |
Time |
16:26 |
Sent To |
|
|
Notes |
2022-03-23 16:29:52 | HALF ADDRESS CHANGED TO 722 58TH ST |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2022-03-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-03-13 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-13 |
Time |
09:11 |
Sent To |
|
|
Notes |
2022-03-13 09:12:35 | DRAWING INDICATES THAT THE WORK IS FOR THE EAST | | BUILDING WITH THE ADDRESS OF 720 58TH ST, HOWEVER THE | | WEST HALF ADDRESS STILL NEED TO BE READDRESSED, PLEASE | | HAVE OWNER CONTACT [email protected] OR CALL 561-805-6659. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-03-09 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-09 |
Time |
13:05 |
Sent To |
|
|
Notes |
2022-03-09 13:05:48 | WHICH BUILDING IS THE WORK TO BE DONE, EAST OR WEST? | | THE WEST BUILDING HAS A HALF ADDRESS WHICH WILL NEED TO | | BE READDRESSED. PLEASE HAVE THE OWNER CONTACT | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | HALF ADDRESS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-18 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-18 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-09 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-09 |
Time |
07:57 |
Sent To |
|
|
Notes |
2022-03-09 10:07:41 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL | | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH | | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. | | PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT | | INDICATE ON ROOF DRAWING/SKETCH). | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW | | POSITIVE DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-18 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-13 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-03-09 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-03-08 |
Time |
06:52 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy