Plan Review Details - Permit 22030035
Plan Review Stops For Permit 22030035
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-03-15 Cont ID  
Sent By rmcphers Date 2022-03-15 Time 13:07 Rev Time 0.00
Received By rmcphers Date 2022-03-15 Time 13:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-30 Cont ID  
Sent By jleahy Date 2022-03-30 Time 16:30 Rev Time 0.00
Received By jleahy Date 2022-03-30 Time 15:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-04 Cont ID  
Sent By pleduc Date 2022-03-04 Time   Rev Time 0.00
Received By pleduc Date 2022-03-04 Time 13:14 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-05-04 Cont ID  
Sent By ccole Date 2022-05-04 Time 09:50 Rev Time 0.00
Received By ccole Date 2022-05-04 Time 07:43 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-04-14 Cont ID  
Sent By ccole Date 2022-04-14 Time 09:16 Rev Time 0.00
Received By ccole Date 2022-04-13 Time 17:00 Sent To  
Notes
2022-04-14 09:16:342ND REVIEW FBC-2020 FUEL GAS
 PERMIT- 22030035
 4/14/2022
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENT #2 FROM THE 1ST
 REVIEW COPIED BELOW STILL EXISTS. PLEASE COMPLY.
  
 2) FAILED. SHEETS P3.1 & P6.1: REFER TO TABLE 402.4(5)
 FBC FG- THE MAIN SUPPLY PIPE FROM THE METER TO THE 1ST
 TEE SHALL BE MINIMUM 1-1/2 FOR THE TOTAL BTU LOAD OF
 3,249,000 AT A DEVELOPED SYSTEM LENGTH OF 141 FT.- SEC.
 402.4.1 FBC FG. THE 1-1/2 MAIN SUPPLY PIPE FROM THE
 METER TO THE 1ST TEE IS NOT INDICATED, AND THE 3/4-INCH
 PIPE FROM THE TEE TO THE LOW PRESSURE REGULATOR IS
 UNDERSIZED. A MINIMUM 1-1/4-INCH PIPE IS REQUIRED- SEE
 TABLE 402.4(5) FBC FG.
  
 2A) THE 23 FT. BRANCHES TO THE WATER HEATERS SHALL BE
 SIZED AT MINIMUM 1-INCH PER TABLE 402.4(2).
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-09 Time 08:33 Rev Time 0.00
Received By ccole Date 2022-03-08 Time 15:55 Sent To  
Notes
2022-03-09 08:33:481ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22030035
 3/9/2022
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P6.1: REVISE THE 2 PSI SYSTEM TOTAL LOAD OF
 1,776,000 BTU TO INCLUDE THE 1,473,000 BTU LOAD OF THE
 GENERATOR- SEC. 402.2 FBC FG.
  
 2) SHEETS P3.1 & P6.1: REFER TO TABLE 492.4(5) FBC FG-
 THE MAIN SUPPLY PIPE FROM THE METER TO THE 1ST TEE
 SHALL BE MINIMUM 1-1/2 FOR THE TOTAL BTU LOAD OF
 3,249,000 AT A DEVELOPED SYSTEM LENGTH OF 141 FT.- SEC.
 402.4.1 FBC FG.
  
 3) P3.1 & P6.1: IT APPEARS THAT THE NEW GAS PIPE TO THE
 GENERATOR WILL BE RUN UNDERGROUND. PLEASE SPECIFY THE
 TYPE OF PIPING AND PROVIDE THE PIPE SIZING TABLE USED-
 SECS. 402.3 & 403.1 FBC FG.
  
 4) P3.1 & P6.1: PLEASE PLACE A NOTE TO INDICATE THE
 GENERATOR INSTALLATION SHALL BE DONE UNDER A SEPARATE
 PERMIT- SECS. 105.1 & 107.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-05-04 Time   Rev Time 0.00
Received By aoliver Date 2022-04-25 Time 07:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-04-14 Time   Rev Time 0.00
Received By aoliver Date 2022-04-07 Time 09:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-30 Cont ID  
Sent By jleahy Date 2022-03-30 Time 16:30 Rev Time 0.00
Received By jleahy Date 2022-03-03 Time 13:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-03-15 Cont ID  
Sent By medwards Date 2022-03-15 Time 17:39 Rev Time 0.00
Received By medwards Date 2022-03-15 Time 17:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-05-04 Cont ID  
Sent By ccole Date 2022-05-04 Time 09:50 Rev Time 0.00
Received By ccole Date 2022-05-04 Time 07:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-04-14 Cont ID  
Sent By ccole Date 2022-04-14 Time 08:46 Rev Time 0.00
Received By ccole Date 2022-04-13 Time 17:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-09 Time 08:07 Rev Time 0.00
Received By ccole Date 2022-03-08 Time 12:45 Sent To  
Notes
2022-03-09 08:07:561ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22030035
 3/9/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P5.1 STORM DRAIN ISO: THE 521 GPM SHOWN AT THE
 VD AND AT THE HD- NOTES 3 AND 4 APPEARS INCORRECT BASED
 ON THE GPM SUB-TOTALS SHOWN UPSTREAM. PLEASE REFER TO
 TABLE 1106.2 FBC P- MINIMUM ? INCH SLOPE IS REQUIRED
 FOR THE 6-INCH HORIZONTAL STORM DRAIN PIPES AT THE BASE
 OF THE SYSTEM.
  
 2) SHEETS P2.3 & P5.1: PLEASE ADJUST THE STORM DRAIN
 CALCULATIONS TO INCLUDE THE GPM FLOWS OF THE CONDENSATE
 FROM THE RTUS- SECS. 314.2- 314.2.2 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-05-04 Cont ID  
Sent By ccole Date 2022-05-04 Time 09:51 Rev Time 0.00
Received By ccole Date 2022-05-04 Time 07:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-04-14 Cont ID  
Sent By ccole Date 2022-04-14 Time 08:46 Rev Time 0.00
Received By ccole Date 2022-04-13 Time 17:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-03-15 Cont ID  
Sent By rmcphers Date 2022-03-15 Time 13:13 Rev Time 0.00
Received By rmcphers Date 2022-03-15 Time 13:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2022-03-11 Cont ID  
Sent By ajones Date 2022-03-11 Time 16:19 Rev Time 0.00
Received By kdefranc Date 2022-03-11 Time 16:19 Sent To  
Notes
***NONE***