Plan Review Details - Permit 22021014
Plan Review Stops For Permit 22021014
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-04-21 Cont ID  
Sent By rmcphers Date 2022-04-21 Time 09:42 Rev Time 0.00
Received By rmcphers Date 2022-04-21 Time 09:42 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By jwitmer Date 2022-04-05 Time 13:35 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-04-05 13:35:42ASBESTOS LETTER IS NOT SIGNED.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-03-02 Cont ID  
Sent By jwitmer Date 2022-03-02 Time 14:57 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-02 14:57:29TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By rmcphers Date 2022-04-26 Time 15:16 Rev Time 0.00
Received By rmcphers Date 2022-04-26 Time 15:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-04-21 Cont ID  
Sent By rmcphers Date 2022-04-21 Time 10:03 Rev Time 0.00
Received By rmcphers Date 2022-04-21 Time 09:35 Sent To  
Notes
2022-04-21 09:41:01REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING (ID-4) SHOW NEW CEILING HEIGHT IN THE
 BATHROOM AND TOILET ROOM AT 82" - MINIMUM CEILING
 HEIGHT IS 84" PER FBC 1208.2 MINIMUM CEILING HEIGHTS.
 OCCUPIABLE SPACES, HABITABLE SPACES AND CORRIDORS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET 6 INCHES
 (2286 MM) ABOVE THE FINISHED FLOOR. BATHROOMS, TOILET
 ROOMS, KITCHENS, STORAGE ROOMS AND LAUNDRY ROOMS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM)
 ABOVE THE FINISHED FLOOR.
  
 2) DRAWING ID-00 HAS THE WRONG CODE VERSION - SHOULD BE
 2020 FBC
  
 3) FOR THE NEW FLOORING - THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By jwitmer Date 2022-04-05 Time 13:33 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-04-05 13:33:20WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22021014
 ADD: 2427 PRESIDENTIAL WAY # 404
 CONT: AVANTE CONSTRUCTION
 TEL: 561-756-6200
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. APRIL 05TH/2022
 ACTION: DENIED
  
  
  
 1) 2ND REQUEST. PLEASE NOTE ALL ID DRAWINGS INDICATE
 THEY WERE DRAWN TO THE 2017 FBC. PLEASE UPDATE ALL
 PLANS, THE 2020 FLORIDA BUILDING CODE, FAMILY OF CODES
 WENT INTO EFFECT ON DEC. 31ST/ 2020 STATEWIDE. PLEASE
 UPDATE YOUR PLANS.
  
 2) THE INTERIOR DESIGNER SEAL, JOSEPH CORTES DOES NOT
 SHOW THE FULL ID NUMBER ID0000511 MISSING THE LAST
 NUMERAL.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-02 Cont ID  
Sent By jwitmer Date 2022-03-02 Time 14:56 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-02 14:56:51WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22021014
 ADD: 2427 PRESIDENTIAL WAY # 404
 CONT: AVANTE CONSTRUCTION
 TEL: 561-756-6200
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MARCH 02/2022
 ACTION: DENIED
  
 1) PLEASE NOTE ALL ID DRAWINGS INDICATE THEY WERE DRAWN
 TO THE 2017 FBC. PLEASE UPDATE ALL PLANS, THE 2020
 FLORIDA BUILDING CODE, FAMILY OF CODES WENT INTO EFFECT
 ON DEC. 31ST/ 2020 STATEWIDE. PLEASE UPDATE YOUR PLANS.
  
 2) THE INTERIOR DESIGNER SEAL, WARREN ARNETT HAS BEEN
 NULL AND VOID SINCE 2001. REVIEW WILL BE PUT ON HOLD
 UNTIL THE INTERIOR DESIGNER SEAL IS NO LONGER A ISSUE.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-04-27 Cont ID  
Sent By fgiaquin Date 2022-04-27 Time 21:59 Rev Time 0.00
Received By fgiaquin Date 2022-04-27 Time 20:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-16 Cont ID  
Sent By fgiaquin Date 2022-03-16 Time 22:35 Rev Time 0.00
Received By fgiaquin Date 2022-03-16 Time 21:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By cwalker Date 2022-04-26 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-04-14 Cont ID  
Sent By cwalker Date 2022-04-14 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2022-03-24 Cont ID  
Sent By cwalker Date 2022-03-24 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-03-24 10:25:15FIRE COMMENTS:
 SUBMISSIONS DID NOT ADDRESS PREVIOUS COMMENTS ON THE
 PLAN SET FOR:
 1) PROVIDE DETAIL ON ANY PENETRATIONS INTO A FIRE RATED
 WALL AND HOW THE RATING WILL BE MAINTAINED. NFPA 101,
 8.3.2
 2) PROVIDE INFORMATION ON THE TESTING OF ALL FLOORING
 MATERIALS TO BE INSTALLED AND THE ACOUSTIC UNDERLAYMENT
 FOR FIRE PERFORMANCE INCLUDING THE CRITICAL RADIANT
 FLUX OF THE MATERIALS. NFPA 101, 10.2.7
 3) ALL FIRE SPRINKLER AND/OR FIRE ALARM SYSTEMS SHALL
 BE MAINTAINED OPERATIONAL AT ALL TIMES DURING DEMO AND
 CONSTRUCTION AND ANY IMPAIRMENT THAT EXCEEDS 4 HOURS OF
 CONTINUOUS DURATION WILL REQUIRE A FIRE WATCH TO BE
 IMPLEMENTED. NFPA 1, 16.4.4
 4) ALL FIRE ALARM AND/OR FIRE SPRINKLER WORK REQUIRES
 SEPARATE PERMITS AND SHOP DRAWINGS TO BE SUBMITTED,
 REVIEWED AND APPROVED PRIOR TO ANY WORK ON THESE LIFE
 SAFETY SYSTEMS BY QUALIFIED CONTRACTORS.
 CHARLES R. WALKER, SENIOR FIRE INSPECTOR
 561-804-4762
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-02-25 Cont ID  
Sent By cwalker Date 2022-02-25 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-02-25 14:22:14FIRE COMMENTS:
 PROVIDE DETAIL ON ANY PENETRATIONS INTO A FIRE RATED
 WALL AND HOW THE RATING WILL BE MAINTAINED. NFPA 101,
 8.3.2
 PROVIDE DETAIL ON THE TESTING OF THE FLOORING AND
 ACOUSTIC UNDERLAYMENT FOR FIRE PERFORMANCE. NFPA 101,
 10.2.7
 PROVIDE NOTE ON PROTECTING ALL LIFE SAFETY/FIRE
 PROTECTION SYSTEMS AND MAINTAINING THEM OPERATIONAL AT
 ALL TIMES DURING THE CONSTRUCTION AND HOW TO ADDRESS
 ANY SYSTEM IMPAIRMENTS. NFPA 1, 16.4.4
 PROVIDE A NOTE THAT ANY WORK ON THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEM MUST BE PERFORMED UNDER SEPARATE
 PERMITS AND CONDUCTED ONLY BY THOSE THAT ARE CERTIFIED
 AND QUALIFIED.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-04-27 Cont ID  
Sent By fgiaquin Date 2022-04-27 Time 22:00 Rev Time 0.00
Received By fgiaquin Date 2022-04-25 Time 14:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-05 Cont ID  
Sent By jwitmer Date 2022-04-05 Time 13:48 Rev Time 0.00
Received By jwitmer Date 2022-03-23 Time 16:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-16 Cont ID  
Sent By fgiaquin Date 2022-03-16 Time 22:35 Rev Time 0.00
Received By fgiaquin Date 2022-02-24 Time 06:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By hmoser Date 2022-04-26 Time 10:21 Rev Time 0.00
Received By hmoser Date 2022-04-26 Time 09:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-04-25 Cont ID  
Sent By hmoser Date 2022-04-25 Time 12:57 Rev Time 0.00
Received By hmoser Date 2022-04-25 Time 11:17 Sent To  
Notes
2022-04-25 12:56:52PLAN DENIED
 1) REFER TO SECTION M1602 RETURN AIR NUMBER 4
 RETURN AIR SHALL NOT BE TAKEN FROM BATHROOMS.
 2020 FBC RESIDENTIAL CODE.
 2) REFER TO SECTION 107.2.1.3 QUALITY OF PLANS
 PLAN IS BLURRY CAN'T READ DUCT SIZE OR CFM.
 3) IS THE AIR CONDITIONING SYSTEM NEW OR EXISTING
 IF NEW PLEASE PROVIDE A EQUIPMENT SCHEDULE.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-04-04 Cont ID  
Sent By hmoser Date 2022-04-04 Time 14:45 Rev Time 0.00
Received By hmoser Date 2022-04-04 Time 14:30 Sent To  
Notes
2022-04-04 14:45:37PLAN DENIED
 NO AIR CONDITIONING PLAN SUBMITTED.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By medwards Date 2022-03-09 Time 09:30 Rev Time 0.00
Received By medwards Date 2022-03-09 Time 09:30 Sent To  
Notes
2022-03-09 09:32:13THE APPLICATION STATES THIS IS A COMPLETE CONDO
 REMODEL. PLEASE PROVIDE A MECHANICAL SCOPE OF WORK
 ALONG WITH THE MECHANICAL DRAWINGS. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-04-14 Cont ID  
Sent By jesmith Date 2022-04-14 Time 15:52 Rev Time 0.00
Received By jesmith Date 2022-04-14 Time 15:02 Sent To  
Notes
2022-04-14 15:52:1622021014 2427 PRESIDENTIAL WAY # 404
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-03-29 Cont ID  
Sent By jesmith Date 2022-03-29 Time 14:17 Rev Time 0.00
Received By jesmith Date 2022-03-29 Time 08:40 Sent To  
Notes
2022-03-29 14:16:19CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22021014 2427 PRESIDENTIAL WAY # 404
  
 2ND REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 1.NEW COMMENT: PLAN SHEET P301/NOTE 212; IT IS BROUGHT
 TO OUR ATTENTION BY THE GENERAL MANAGER OF THE CONDO
 ASSOCIATION THAT THE RELOCATED DRAIN PIPE FOR THE
 KITCHEN SINK IS A WASTE STACK VENT WHICH RISES
 VERTICALLY THROUGH THE KITCHEN WALL IN THE GENERAL
 VICINITY OF THE KITCHEN SINK. PLEASE NOTE THAT WASTE
 STACK VENTS SHALL NOT BE OFFSET VERTICALLY OR
 HORIZONTALLY PER FBC PL 913.2 AND AS SUCH SHALL REMAIN
 IN THE ORIGINAL LOCATION. PER WPB FBC 107.2.1, MAKE
 CORRECTION TO DRAWING AS NEEDED AND RESUBMIT.
  
 2.REVISED P-801; SANITARY RISER DIAGRAMS ARE
 INCOMPLETE. FLOOR PENETRATIONS ARE SHOWN; HOWEVER,
 THERE IS NO DRAINAGE OR VENTING SHOWN. PER WPB FBC
 107.2.1, CORRECT AND RESUBMIT.
  
 3.REGARDING THE NEWLY PROVIDED SHOWER
 THRESHOLD/LINER/WALL DETAIL, PER WPB FBC 107.2.1,
 PLEASE PROVIDE THE FOLLOWING INFORMATION AS WAS
 PREVIOUSLY REQUESTED.
 ***A) DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL
 421.5.2 AS FOLLOWS:
 LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2
 INCHES ABOVE THE FINISHED THRESHOLD LEVEL
 LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED
 BACKING
 LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT
 LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD
 LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED
 TOWARD THE FIXTURE DRAIN
 LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET
 AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT
 BETWEEN THE LINER AND THE OUTLET
 FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE
 LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY
 SOUND BASE.
 ***B) LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING
 WITH ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1,
 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR
 421.5.2.6.)
 ***C) FBC PL 421.4.1: WALLS IN SHOWER COMPARTMENTS
 SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND
 NONABSORBENT WATERPROOF MATERIALS NOT LESS THAN 6 FEET
 ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES
 ABOVE THE DRAIN OF THE SHOWER.
 ***D) FBC PL 421.4.1 AND 421.5: FLOOR SURFACES SHALL BE
 CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE, NONABSORBENT
 AND WATERPROOF MATERIALS
 ***E) NEW COMMENT: REGARDING THE LINER EXTENDING INTO
 THE BATHROOM FLOOR, PER WPB FBC 107.2.1, PROVIDE
 DETAIL/DIRECTION FOR SHEET APPLIED OR TROWEL APPLIED
 METHODS TO PREVENT WATER FROM MIGRATING BACK TO THE
 SHOWER DRAIN PIPE FLOOR PENETRATION.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 22021014 2427 PRESIDENTIAL WAY # 404
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-03-03 Cont ID  
Sent By jesmith Date 2022-03-03 Time 11:17 Rev Time 0.00
Received By jesmith Date 2022-03-01 Time 15:43 Sent To  
Notes
2022-03-03 11:10:38CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22021014 2427 PRESIDENTIAL WAY # 404
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 1. PLAN SHEET P301
 ...A) REGARDING NOTES 208, 209 AND 210: PER WPB FBC
 107.2.1, PROVIDE COMPLIANT SANITARY RISER DIAGRAM FOR
 EACH NEW SHOWER INSTALLATION. TO SHOW COMPLIANCE WITH
 FBC PL CHAPTERS 7, 9 AND 10, SHOW FIXTURE DRAINS,
 APPLICABLE BRANCH AND/OR STACK CONNECTIONS, TRAPS AND
 VENTING; INCLUDE SIZES.
 ...B) REGARDING NOTE 206: PER WPB FBC 107.2.1, ADD TO
 NOTE "THE WASTE CONNECTION OF A RESIDENTIAL DISHWASHER
 SHALL CONNECT DIRECTLY TO A WYE BRANCH FITTING ON THE
 TAILPIECE OF THE KITCHEN SINK, DIRECTLY TO THE
 DISHWASHER CONNECTION OF A FOOD WASTE DISPOSER, OR
 THROUGH AN AIR BREAK TO A STANDPIPE. THE WASTE LINE OF
 A RESIDENTIAL DISHWASHER SHALL RISE AND BE SECURELY
 FASTENED TO THE UNDERSIDE OF THE SINK RIM OR COUNTER
 TOPPER FBC PL 409.4."
 ...C) REGARDING NOTE 203: PER WPB FBC 107.2.1, PROVIDE
 CROSS SECTION SHOWER THRESHOLD/LINER/WALL DETAIL AS
 FOLLOWS:
 ......1) FBC PL 421.4.1: WALLS IN SHOWER COMPARTMENTS
 SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND
 NONABSORBENT WATERPROOF MATERIALS NOT LESS THAN 6 FEET
 ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES
 ABOVE THE DRAIN OF THE SHOWER.
 ......2) FBC PL 421.4.1 AND 421.5: FLOOR SURFACES SHALL
 BE CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE,
 NONABSORBENT AND WATERPROOF MATERIALS
 ......3) FBC PL 421.5.2: LINERS SHALL TURN UP ON ALL
 SIDES NOT LESS THAN 2 INCHES ABOVE THE FINISHED
 THRESHOLD LEVEL
 ......4) FBC PL 421.5.2: LINERS SHALL BE RECESSED AND
 FASTENED TO AN APPROVED BACKING
 ......5) FBC PL 421.5.2: LINERS SHALL NOT BE NAILED OR
 PERFORATED AT ANY POINT LESS THAN 1 INCH ABOVE THE
 FINISHED THRESHOLD
 ......6) FBC PL 421.5.2: LINERS SHALL BE PITCHED
 ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL
 (2-PERCENT SLOPE) AND SHALL BE SLOPED TOWARD THE
 FIXTURE DRAIN
 ......7) FBC PL 421.5.2: LINERS SHALL BE SECURELY
 FASTENED TO THE WASTE OUTLET AT THE SEEPAGE ENTRANCE,
 MAKING A WATER-TIGHT JOINT BETWEEN THE LINER AND THE
 OUTLET
 ......8) FBC PL 421.5: FLOORS OR RECEPTORS UNDER SHOWER
 COMPARTMENTS SHALL BE LAID ON, AND SUPPORTED BY, A
 SMOOTH AND STRUCTURALLY SOUND BASE.
 ......9) FBC PL 421.5.2: LINER MATERIAL (SPECIFY LINER
 MATERIAL COMPLYING WITH ONE OF THE FOLLOWING FBC PL
 SECTIONS-421.5.2.1, 421.5.2.2, 421.5.2.3, 421.5.2.4,
 421.5.2.5 OR 421.5.2.6.) NOTE THAT FBC PL 421.5.2.1
 PLASTICIZED POLYVINYL CHLORIDE (PVC) SHEETS MEETING THE
 REQUIREMENTS OF ASTM D4551 IS A COMMON LINER USED.
 ...D) REGARDING NOTE 201: NOTE IS UNCLEAR. ARE TWO NEW
 LAVATORIES REPLACING ONE EXISTING LAVATORY OR TWO
 EXISTING LAVATORIES? PER WPB FBC 107.2.1, CLARIFY. IF
 TWO ARE REPLACING ONE, THEN PER WPB FBC 107.2.1,
 PROVIDE SANITARY RISER DIAGRAM SHOWING THE NEW
 CONFIGURATION AND COMPLIANCE WITH FBC PL SECTIONS 909,
 911.
 ...E) PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC
 PL 704.1, PROVIDE NOTE STATING "HORIZONTAL DRAINAGE
 PIPING LESS THAN 3 INCH DIAMETER SHALL HAVE A MINIMUM
 SLOPE OF 1/4 INCH PER FOOT. 3 INCH TO 6 INCH DIAMETER
 SHALL HAVE A MINIMUM SLOPE OF 1/8 INCH PER FOOT."
  
 2.PLAN SHEET P401:
 ...A) REGARDING NOTE 110: PER WPB FBC 107.2.1, PROVIDE
 THE FOLLOWING NOTES.
 ......1) MANUFACTURER'S SPECIFICATION/INSTALLATION
 MANUALS FOR THE HAND-HELD SHOWERS AND THE INDIVIDUAL
 SHOWER VALVES SHALL BE ON SITE FOR INSPECTION.
 ......2) HAND-HELD SHOWERS SHALL CONFORM TO ASME
 A112.18.1/CSA B125.1. HAND-HELD SHOWERS SHALL PROVIDE
 BACKFLOW PROTECTION IN ACCORDANCE WITH ASME
 A112.18.1/CSA B125.1 OR SHALL BE PROTECTED AGAINST
 BACKFLOW BY A DEVICE COMPLYING WITH ASME A112.18.3 PER
 FBC PL 412.2.
 ......3) INDIVIDUAL SHOWER AND TUB-SHOWER COMBINATION
 VALVES SHALL BE BALANCED-PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT
 CONFORM TO THE REQUIREMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1 AND
 SHALL BE INSTALLED AT THE POINT OF USE. SHOWER AND
 TUB-SHOWER COMBINATION VALVES REQUIRED BY THIS SECTION
 SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUM
 SETTING OF THE VALVE TO 120DEGREES F, WHICH SHALL BE
 FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURE'S
 INSTRUCTIONS. IN-LINE THERMOSTATIC VALVES SHALL NOT BE
 UTILIZED FOR COMPLIANCE WITH THIS SECTION PER FBC PL
 412.3.
  
 3. PLAN SHEET P801/WATER HEATER SCHEDULE: SCHEDULED
 A.O. SMITH PNLB-50 APPEARS TO HAVE BEEN REPLACED BY
 ENLB 50. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUALS FOR THE WATER
 HEATER;
 ...A) HIGHLIGHT THE CORRECT MODEL NUMBER
 ...B) PROVIDE NOTE STATING MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUALS FOR THE WATER HEATER
 SHALL BE SHALL BE ON SITE FOR INSPECTION.
  
 4.WATER HEATER SCHEDULE & DETAIL- PROVIDE DETAIL OF
 WATER HEATER SHOWING HEATER W/STORAGE CAPACITY, PIPING
 INCLUDING CW, HW, VALVES (INCLUDING VACUUM RELIEF VALVE
 IF APPLICABLE FBC PL 504.2) , THERMAL EXPANSION CONTROL
 DEVICE (INCLUDING SIZE), T&P DISCHARGE (INCLUDING
 TERMINATION) AND WATER HEATER PAN AND DRAIN (INCLUDING
 TERMINATION) PER WPB FPC 107.2.1; COMPLY WITH FBC PL
 607.3, 503.1, 504.1, 504.4, 504.4.1, 504.5, 504.6,
 504.7, 504.7.1 AND 504.7.2. PLEASE NOTE THAT PER FBC PL
 504.7.2, WHERE A PAN DRAIN WAS NOT PREVIOUSLY
 INSTALLED, A PAN DRAIN SHALL NOT BE REQUIRED FOR A
 REPLACEMENT WATER HEATER INSTALLATION. IF THIS IS THE
 CASE, PLEASE INDICATE SUCH ON THE DETAIL.
  
 5.ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE
 LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1.
 PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS STATING THE
 SAME.
  
 6.PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL FOR
 ADDED SHOWER FIXTURE DRAINS WITH A NOTE STATING,
 "HORIZONTAL PIPE SHALL BE SUPPORTED IN ACCORDANCE WITH
 FBC PL TABLE 308.5."
  
 7.PER WPB FBC 107.2.1, PROVIDE RATED UL FLOOR
 PENETRATION ASSEMBLY DETAIL FOR THE NEW SHOWER DRAIN
 PENETRATIONS COMPLYING WITH FBC CHAPTER 7.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 22021014 2427 PRESIDENTIAL WAY # 404
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By rmcphers Date 2022-04-26 Time 15:16 Rev Time 0.00
Received By rmcphers Date 2022-04-26 Time 15:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-04-21 Cont ID  
Sent By rmcphers Date 2022-04-21 Time 10:00 Rev Time 0.00
Received By rmcphers Date 2022-04-21 Time 10:00 Sent To  
Notes
2022-04-21 10:03:26SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS ID-00 AND M-1 DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER - DRAWING M-1 NEEDS TO BE SIGNED
 BY THE DESIGNER.
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
2022-04-14 15:33:28P-301, P-801-SIGNATURES FOR PLUMBING ARE VALID. JS
 P-000, P-401SIGNATURES FOR PLUMBING: SELECTED
 CERTIFICATE PATH HAS ERRORS; NOT TIME VALID.
 CORRECTIONS NEEDED. JS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-04-06 Cont ID  
Sent By jwitmer Date 2022-04-05 Time 13:47 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-29 12:09:40SIGNATURES FOR PLUMBING: SELECTED CERTIFICATE HAS
 ERRORS; NOT TIME VALID. CORRECTIONS NEEDED. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By jleahy Date 2022-02-24 Time 16:26 Rev Time 0.00
Received By jleahy Date 2022-02-24 Time 16:26 Sent To  
Notes
2022-02-24 16:27:002/24/22 PAPER PLANS SENT TO STORAGE JLEAHY