Plan Review Details - Permit 22020991
Plan Review Stops For Permit 22020991
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By rmcphers Date 2022-03-07 Time 14:55 Rev Time 0.00
Received By rmcphers Date 2022-03-07 Time 14:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-04-05 Cont ID  
Sent By rmcphers Date 2022-04-05 Time 11:46 Rev Time 0.00
Received By rmcphers Date 2022-04-05 Time 11:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By rmcphers Date 2022-03-07 Time 14:55 Rev Time 0.00
Received By rmcphers Date 2022-03-07 Time 14:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-04-05 Cont ID  
Sent By mpeterso Date 2022-04-05 Time 09:05 Rev Time 0.00
Received By mpeterso Date 2022-04-05 Time 09:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-03-10 Cont ID  
Sent By jleahy Date 2022-03-10 Time 16:42 Rev Time 0.00
Received By jleahy Date 2022-03-10 Time 16:39 Sent To  
Notes
2022-03-10 16:43:04NO ELECTREICAL WORK SHOWN OR REVIEWED JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-03-30 Cont ID  
Sent By cwalker Date 2022-03-30 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-03-30 10:47:29FIRE REVIEW COMMENTS:
 THE NEW DOUBLE DOOR INSTALLATION MAY REQUIRE A FIRE
 RESISTANCE RATING AND SELF-CLOSING DEVICES WITH
 POSITIVE LATCHING. PROVIDE DOCUMENTATION THAT THE NEW
 DOOR ASSEMBLY PROVIDES ADEQUATE PROTECTION IN THE
 OPENING IN THE CMU WALL ON THE FIRST FLOOR BETWEEN THE
 EXISTING WORK AREA AND THE EXISTING WAREHOUSE. NFPA 101
 8.3.3
 ACKNOWLEDGE RECEIPT OF THE LETTER FROM WIGINTON FIRE
 SYSTEMS CONCERNING COVERAGE.
 ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEM REQUIRES SEPARATE PERMIT AND SHOP DRAWINGS
 TO BE SUBMITTED AND APPROVED PRIOR TO ANY WORK BEING
 CONDUCTED ON THESE SYSTEMS.
 THE FIRE SPRINKLER AND/OR FIRE ALARM SYSTEMS MUST
 REMAIN ACTIVE DURING ALL PHASES OF DEMOLITION AND
 CONSTRUCTION.
 C.R. WALKER, SENIOR FIRE INSPECTOR
 561-804-4762
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-03-02 Cont ID  
Sent By clfranci Date 2022-03-02 Time   Rev Time 0.00
Received By clfranci Date 2022-03-02 Time   Sent To  
Notes
2022-03-02 07:47:45THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L.
 FRANCIS, FIRE INVESTIGATOR, WITH THE FOLLOWING
 COMMENTS:
  
 1) PROVIDE DOOR AND WALL DETAILS FOR DOORS, ROLL UP
 DOORS, WALLS BEING ADDED, AND OR FILLED.
  
 1.14.1 WHERE REQUIRED BY THE AHJ FOR NEW CONSTRUCTION,
 MODIFICATION, OR REHABILITATION, CONSTRUCTION DOCUMENTS
 AND SHOP DRAWINGS SHALL BE SUBMITTED, REVIEWED, AND
 APPROVED PRIOR TO THE START OF SUCH WORK AS PROVIDED IN
 SECTION 1.14.
  
 2) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 FIRE SPRINKLER AND FIRE ALARM SYSTEMS FOR CODE COVERAGE
 AND COMPLIANCE BY CERTIFIED CONTRACTORS.
  
 3) ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY CERTIFIED CONTRACTORS.
  
 4) THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL
 REMAIN ACTIVE THROUGHOUT THE DEMO AND CONSTRUCTION
 PERIODS.
  
 5) COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 6) FOR THE RECORD PLEASE PROVIDE THE EXISTING EXIT
 SIGNS AND EMERGENCY LIGHTING FOR EVALUATION PER NFPA
 101 CHAPTER 7.
  
  
  
 CAITLIN L. FRANCIS
 FIRE INVESTIGATOR
 561-804-4728
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-18 Cont ID  
Sent By jgomez Date 2022-04-18 Time 13:17 Rev Time 0.00
Received By jgomez Date 2022-04-17 Time 08:52 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-04-15 Cont ID  
Sent By medwards Date 2022-04-15 Time 07:04 Rev Time 0.00
Received By medwards Date 2022-04-10 Time 08:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-06 Cont ID  
Sent By medwards Date 2022-04-06 Time 09:54 Rev Time 0.00
Received By medwards Date 2022-03-29 Time 09:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-10 Cont ID  
Sent By jleahy Date 2022-03-10 Time 16:43 Rev Time 0.00
Received By jleahy Date 2022-02-23 Time 09:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-04-15 Cont ID  
Sent By medwards Date 2022-04-15 Time 07:00 Rev Time 0.00
Received By medwards Date 2022-04-15 Time 07:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-04-06 Cont ID  
Sent By medwards Date 2022-04-06 Time 09:53 Rev Time 0.00
Received By medwards Date 2022-04-06 Time 09:53 Sent To  
Notes
2022-04-06 09:54:081ST REVIEW FMC
 PERMIT: 22020991
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE UPDATE THE COVER SHEET TO INCLUDE THE ADDED
 MECHANICAL SHEETS. FBC 107.2.1
  
 2) THE UNITS BEING REPLACED, ARE THEY LIKE FOR LIKE
 CHANGE OUTS? IF SO PLEASE PROVIDE THE LIKE FOR LIKE
 CHANGE OUT FORMS FOR EACH, IF NOT PLEASE PROVIDE
 EQUIPMENT SIZING CALCULATIONS FOR EACH. FBC 107.2.1
  
 3) SHEET M-2: KEYNOTE 3 STATES YOU WILL ABANDON THE
 EXHAUST FANS AND CAP THEM AT THE ROOF. FMC 403.3.1.1
 AND TABLE 403.3.1.1 TELL US WE SHALL PROVIDE
 VENTILATION PER THE TABLE. PLEASE PROVIDE THE OUTDOOR
 AIR CALCULATIONS FOR THIS WAREHOUSE. FMC TABLE
 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-04-18 Cont ID  
Sent By jgomez Date 2022-04-18 Time 13:17 Rev Time 0.00
Received By jgomez Date 2022-04-18 Time 13:14 Sent To  
Notes
2022-04-17 08:52:20DIGITALLY SIGNED FILES IN SIGNATURES FOLDER

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-04-15 Cont ID  
Sent By medwards Date 2022-04-15 Time 07:03 Rev Time 0.00
Received By medwards Date 2022-04-15 Time 07:03 Sent To  
Notes
2022-04-15 07:03:53PLEASE SEE PREVIOUS COMMENTS BELOW:
  
 SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A.1 AND D.1 DO NOT SHOW AS DIGITALLY SIGNED
 IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By rmcphers Date 2022-04-05 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2022-04-05 Time 11:51 Sent To  
Notes
2022-04-05 11:52:51SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A.1 AND D.1 DO NOT SHOW AS DIGITALLY SIGNED
 IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By rmcphers Date 2022-03-07 Time 14:56 Rev Time 0.00
Received By rmcphers Date 2022-03-07 Time 14:56 Sent To  
Notes
***NONE***