|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22020687
Plan Review Stops For Permit 22020687 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-15 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-15 |
Time |
11:26 |
Sent To |
|
|
Notes |
2022-02-15 11:30:00 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | FOR OPENINGS 3 & 4, IN ADDITION TO THE TOP | | TRUSSCONNECTIONSAT 24"O.C., CONNECTIONS TO 1/4" FLAT | | BAR ARE AT 6" O.C. AS PER PRODUCT APPROVAL FL 17080-R3 | | SHEET 12 OF 13. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-12 |
Time |
07:42 |
Sent To |
|
|
Notes |
2022-02-12 08:09:11 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, THE SUBMITTED SCHEDULE APPEARS TO BE | | INCOMPLETE. FOR OPENINGS 3 AND 4 AN ADDITIONAL NOTE | | SHOULD BE ADDED. THIS NOTE NEEDS TO CLARIFY THAT IN | | ADDITION TO THE TOP TRUSS CONNECTIONS AT 24" O.C., | | CONNECTIONS TO 1/4" FLAT BAR ARE AT 6" O.C. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-11 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-12 |
Time |
07:42 |
Sent To |
|
|
Notes |
2022-02-12 07:58:22 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | SIGNATURE REVIEW APPROVED BY SUBMITTED HAND | | SIGNED/SEALED PAPER WINDLOAD DOCUMENT. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |