Plan Review Details - Permit 22020521
Plan Review Stops For Permit 22020521
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-02-17 Cont ID  
Sent By cpuell Date 2022-02-17 Time 10:12 Rev Time 0.00
Received By cpuell Date 2022-02-17 Time 10:12 Sent To  
Notes
2022-02-17 10:12:59300 BANYAN BLVD AND 308 BANYAN BLVD PREVIOUSLY AGREED
 UPON FOR THE PROJECT.

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2022-03-21 Cont ID  
Sent By scwelter Date 2022-03-21 Time 15:04 Rev Time 0.00
Received By scwelter Date 2022-03-21 Time 15:08 Sent To  
Notes
2022-03-21 15:08:01APPLICANT SUBMITTED ART ASSESSMENT APPLICATION ON
 3.15.2022 OPTION 1 ART ON SITE FUNDS HAVE BEEN ESCROWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-01 Cont ID  
Sent By rmcphers Date 2022-07-01 Time 13:08 Rev Time 0.00
Received By rmcphers Date 2022-07-01 Time 13:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 14:47 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 14:47 Sent To  
Notes
2022-06-30 14:48:36NEW 12 STORY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
  
 1) I DO NOT SEE THE REQUIRED STATEMENT ON THE
 ARCHITECTURAL DRAWINGS - THE STRUCTURAL DRAWINGS HAVE A
 PARTIAL STATEMENT - WILL NEED THE FULL STATEMENT ON THE
 ARCHITECTURAL AND STRUCTURAL DRAWINGS. FBC WPB
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED
 BY THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A
 STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE
 FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633.
 FLORIDA STATUTES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-04 Cont ID  
Sent By rmcdouga Date 2022-05-04 Time 09:19 Rev Time 0.00
Received By rmcdouga Date 2022-04-20 Time 13:06 Sent To  
Notes
2022-04-26 17:02:12PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC 7TH EDITION (2020) & CITY OF W.P.B.
 CHAPTER 1 AMENDMENTS
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
 300 BANYAN BLVD.
 PERMIT #22020521
 170 MPH, EXPOSURE "D"
 FLOOD ZONE "X"
 HIGH-RISE BLDG. PER FBC 403 (12 STORIES, 152'-0" TO TOP
 OF OCCUPIED LEVEL)
 CONSTRUCTION TYPE: IA (REDUCED TO IB FOR FIRE
 RESISTANCE RATING OF BUILDING MATERIALS PER FBC
 403.2.1.1)
 PROPOSED OCCUPANCY TYPE: (MIXED USE) B, S-2, A-3
 BLDG. AND GARAGE ARE FULLY SPRINKLERED
 GARAGE IS ENCLOSED
  
 DENIED BY BUILDING
  
 THIS REVIEW IS FOR THE FOUNDATION AND THE BUILDING
 SUPER STRUCTURE. THE FIRST REVIEW WAS FOR THE
 FOUNDATION ONLY PER REQUEST. ADDITIONAL ITEMS WILL BE
 REQUIRED FOR THIS REVIEW. THE PLANS FOR THE COMPLETE
 BUILDING HAVE NOT BEEN SUBMITTED AT THIS TIME. PLEASE
 ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SITE PLANS ARE MISSING DIMENSIONS, SUCH AS THE
 DISTANCES TO THE PROPERTY LINES. PROVIDE A SITE PLAN
 WITH DIMENSIONS.
  
 2) THE FLOOR PLANS ARE MISSING DIMENSIONS. PROVIDE
 DIMENSIONED FLOOR PLANS. THI IS NEEDED TO CHECK SUCH
 THINGS AS FIRE LOBBY SIZE PER FBC 3007.6, SEPARATION OF
 EXIT ACCESS STAIRWAYS FBC 403.5.1 & 1007.1, ETC.
  
 3) THE DISTANCE TO THE PROPERTY LINE AT THE WEST
 ELEVATION APPEARS TO BE RATHER TIGHT. PROVIDE
 CALCULATIONS TO SHOWN THAT THE PERCENTAGES OF ALLOWABLE
 OPENINGS PER STORY ON THE WEST WALLS COMPLY WITH FBC
 705.8.1 & TABLE 705.8.
  
 4) PROVIDE A LIFE SAFETY PLAN. FBC CHAPTER 10
 THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING:
 A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1
 B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1
 C) EXIT SEPARATION DISTANCE FBC 1015.2.1
 D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3
 E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3
 F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC
 1008.1.1
 G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND
 MEANS OF EGRESS FACTOR FBC1005.3.2
 H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5
  
 5) PLEASE CLARIFY IF THE ATTACHED GARAGE IS DESIGNED TO
 BE ENCLOSED OR OPEN. IF IT IS AN OPEN GARAGE PROVIDE
 CALCULATIONS TO SHOW THAT IT COMPLIES WITH FBC 406.5.2.
  
 6) SHOW COMPLIANCE. FBC 3002.4 REQUIRES ANY BUILDING
 THAT IS MORE THAN THREE STORIES HIGH OR IN WHICH THE
 VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL LANDING
 AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET TO BE
 CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER ELEVATOR
 THAT IS OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE
 DEPARTMENT ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL
 BE OF A SIZE AND ARRANGEMENT TO ACCOMMODATE AN
 AMBULANCE STRETCHER 24 INCHES BY 76 INCHES WITH NOT
 LESS THAN 5-INCH RADIUS CORNERS, IN THE HORIZONTAL,
 OPEN POSITION AND SHALL BE IDENTIFIED BY THE
 INTERNATIONAL SYMBOL FOR EMERGENCY MEDICAL SERVICES
 (STAR OF LIFE).
  
 7) SHOW THAT THE FIRE SERVICE ELEVATOR LOBBY COMPLIES
 WITH FBC 3007.6.4 LOBBY SIZE. REGARDLESS OF THE NUMBER
 OF FIRE SERVICE ACCESS ELEVATORS SERVED BY THE SAME
 ELEVATOR LOBBY, THE ENCLOSED FIRE SERVICE ACCESS
 ELEVATOR LOBBY SHALL BE NOT LESS THAN 150 SQUARE FEET
 (14 M2) IN AN AREA WITH A DIMENSION OF NOT LESS THAN 8
 FEET (2440 MM). SEE SHEET A6.1.2 (PG. 157) AND OTHER
 SHEETS.
  
 8) SHOW COMPLIANCE. 403.6.1 FIRE SERVICE ACCESS
 ELEVATOR. IN BUILDINGS WITH AN OCCUPIED FLOOR MORE THAN
 120 FEET (36 576 MM), MEASURED FROM THE ELEVATION OF
 STREET-LEVEL ACCESS TO THE LEVEL OF THE HIGHEST
 OCCUPIABLE FLOOR, NO FEWER THAN TWO FIRE SERVICE ACCESS
 ELEVATORS SHALL BE PROVIDED IN ACCORDANCE WITH SECTION
 3007. ALL REMAINING ELEVATORS, IF ANY, SHALL BE
 PROVIDED WITH PHASE I AND II EMERGENCY OPERATION. EACH
 FIRE SERVICE ACCESS ELEVATOR SHALL HAVE A CAPACITY OF
 NOT LESS THAN 3,500 POUNDS (1588 KG).
  
 9) PROVIDE A SCHEMATIC DIAGRAM OF THE FIRE SPRINKLERS.
 FBC 107.3.5.1
  
 10) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL
 MULLIONS, EXTERIOR WALL VENTS AND EXTERIOR DOOR TYPES.
 THESE ITEMS CAN BE DEFERRED IF REQUESTED, HOWEVER, THE
 DOCUMENTS MUST BE SUBMITTED AND APPROVED BY THE
 BUILDING DEPARTMENT BEFORE THEY CAN BE INSTALLED.
  
 11) FBC AMENDMENTS 107.3.4.1 DEFERRED SUBMITTALS. FOR
 THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 12) SHOW COMPLIANCE WITH FBC 2304.12 FOR TERMITE
 PROTECTION.
  
 13) VERIFY THE REQUIRED VERTICAL CLEARANCE OF 98 INCHES
 FOR THE VAN PARKING SPACE, ACCESS AISLE AND VEHICULAR
 ROUTE SERVING IT AS REQUIRED BY FBC ACCESSIBILITY
 SECTION 502.5. THERE HAVE BEEN ISSUES WITH EQUIPMENT OR
 SYSTEMS INSTALLED BELOW THE REQUIRED 98" IN THESE AREAS
 OF PARKING GARAGES. PLEASE PROVIDE NOTES ON THE
 DRAWINGS TO HELP AVOID THIS ISSUE.
  
 14 ) THE VALUATION FOR THIS BUILDING HAS BEEN
 DETERMINED TO BE $43,968,715.77 BASED ON THE CURRENT
 ICC BUILDING VALUATION DATA. THE FOUNDATION AND
 SUPERSTRUCTURE PERMIT VALUATION WILL BE 80 PERCENT OF
 THAT TOTAL OR $35,174,972.61. THE REMAINDER WILL BE
 USED FOR THE VALUATION OF THE INTERIOR BUILD-OUT OF THE
 BUILDING. THE FBC 109.3 BUILDING PERMIT VALUATION. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 15) SEPARATE PERMITS, REVIEWS AND FEES ARE REQUIRED FOR
 SOME ITEMS THAT MAY HAVE BEEN INCLUDED IN THE VALUE FOR
 THIS PROJECT. ITEMS SUCH AS FIRE ALARM, FIRE SPRINKLER,
 LOW VOLTAGE, LANDSCAPING, IRRIGATION AND ALL ITEMS
 OTHER THAN BUILDING, MECHANICAL, ELECTRIC AND PLUMBING.
 WHEN APPLYING FOR THE PERMIT TO COMPLETE THE BUILDING,
 PROVIDE A COST BREAKDOWN SO THAT WE CAN DEDUCT THESE
 ITEMS FROM THE PERMIT VALUE SO THAT YOU WILL NOT BE
 CHARGED TWICE FOR THE SAME ITEM.
  
 16) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
 ****PROVISOS****
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 A SEPARATE ROOF PERMIT IS REQUIRED. PRIOR TO
 INSTALLATION, SUBMIT ROOF PERMIT APPLICATION WITH
 PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD AND
 ENGINEERING (IF APPLICABLE).
  
 COMPONENT & CLADDING PRODUCT APPROVALS REVIEWED BY
 DESIGNER OF RECORD ARE TO BE SUBMITTED TO THE BUILDING
 DIVISION, REVIEWED AND ISSUED PRIOR TO INSTALLATION.
  
 DEFERRED SUBMITTALS REQUESTED BY ARCHITECT, SEE
 FOLLOWING LIST (MAY NOT BE A COMPLETE LIST); DOCUMENTS
 SHOWING COMPLIANCE ARE TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL (ARCHITECT OR ENGINEER FOR
 PRODUCT APPROVALS AND OTHER SPECIFICATION DOCUMENTS,
 STRUCTURAL ENGINEER OF RECORD APPROVAL AND REVIEW IS
 REQUIRED FOR DELEGATED ENGINEERING). SUBMITTAL, REVIEW
 AND APPROVAL ARE REQUIRED PRIOR TO INSTALLATION.
  
 COMPONENT & CLADDING PRODUCT APPROVALS (COMPLY WITH
 PRESSURES SHOWN ON SHEET S0.0.5)
  
 COMPONENT & CLADDING PRODUCT APPROVALS REVIEWED BY
 DESIGNER OF RECORD ARE TO BE SUBMITTED TO THE BUILDING
 DIVISION, REVIEWED AND ISSUED PRIOR TO INSTALLATION.
 CONFIRM COMPLIANCE WITH PRESSURES SHOWN ON SHEET S0.0.5
 PRIOR TO SUBMITTAL. IF PRODUCT APPROVAL OFFERS OPTIONS,
 INDICATE OPTION PROPOSED, ESPECIALLY IF NOT ALL OPTIONS
 COMPLY WITH MINIMUM DESIGN PRESSURES.
  
 SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE
 REQUIRED FOR:
 LIGHT POLES/SITE LIGHTING
 FIRE ALARM
 FIRE SPRINKLER
 LOW VOLTAGE
 ACCESS
 LANDSCAPING
 IRRIGATION
 PARKING LOT
 SWIMMING POOLS
 ALL OTHER ITEMS OTHER THAN BMEP
  
 PROVIDE THE RECORDED PLAT WHEN FINALIZED; EITHER A PDF
 VIA EMAIL OR ADVISE BOOK AND PAGE NUMBER VIA EMAIL.
  
 AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED PRIOR
 TO C.O.
  
 SHORING/RESHORE ENGINEERING IS REQUIRED TO BE SUBMITTED
 TO THE BUILDING DIVISION FOR REVIEW. THE ENGINEERING IS
 TO BE SUBMITTED, REVIEWED AND ISSUED PRIOR TO CONCRETE
 POUR.
  
 A CONSTRUCTION GUARD RAIL ENGINEERED DETAIL IS REQUIRED
 TO BE PROVIDED PRIOR TO INSTALLATION.
  
 CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM
 SAT-SUN
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-08 Cont ID  
Sent By rmcdouga Date 2022-03-08 Time 17:38 Rev Time 0.00
Received By rmcdouga Date 2022-03-08 Time 17:38 Sent To  
Notes
2022-03-08 16:33:01PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 FOUNDATION PERMIT
 300 BANYAN BLVD.
 12 STORY OFFICE BUILDING AND PARKING GARAGE
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT AN AREA BREAK DOWN OF THE BUILDING. SPECIFY
 THE BUSINESS AREA, GARAGE AREA, BALCONY AREA, ROOF
 TERRACE AREA, ETC. FBC AMENDMENTS 107.2.1
  
 2) SPECIFY THE TYPE OF CONSTRUCTION, NUMBER OF STORIES,
 BUILDING HEIGHT AND AREAS AND THE TYPES OF OCCUPANCY
 FOR THE BUILDING, FBC 503
  
 3) SUBMIT A MANAGEMENT OF TRAFFIC (MOT) PLAN ALONG WITH
 A SAFEGUARDS DURING CONSTRUCTION PLAN. PROVIDE A
 DRAWING THAT SHOWS THE LOCATION OF ALL FENCING,
 BARRIERS, GATES, BARRICADES, LOCATION OF TOWER CRANES,
 STAGING AREAS, ETC. SPECIFY WHAT METHODS WILL BE
 EMPLOYED TO PROTECT ADJACENT PROPERTIES DURING THE
 CONSTRUCTION PROCESS. FBC CHAPTER 33
  
 4) PROVIDE LIFE SAFETY PLANS. SHOW THE EXITS, THE
 SEPARATION DISTANCE OF THE EXITS, OCCUPANT LOADS, EXIT
 CAPACITY, TRAVEL DISTANCES, ETC. FBC CHAPTER 10
 THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING:
 A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1
 B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1
 C) EXIT SEPARATION DISTANCE FBC 1015.2.1
 D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3
 E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3
 F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC
 1008.1.1
 G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND
 MEANS OF EGRESS FACTOR FBC1005.3.2
 H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5
  
 5) THE VALUATION FOR THIS FOUNDATION PERMIT IS LISTED
 AS $12,087,000.00. BECAUSE THIS PERMIT IS ONLY FOR THE
 BUILDINGS FOUNDATION, I NEED TO KNOW WHAT THE COST IS
 FOR JUST THE SCOPE OF WORK THAT WILL BE COVERED BY THIS
 FOUNDATION PERMIT, SO THAT I CAN ADJUST THE PERMIT
 VALUATION ACCORDINGLY. I WILL VERIFY THE BUILDINGS
 TOTAL VALUE WHEN YOU PROVIDE THE TYPE OF CONSTRUCTION
 AND AREAS OF EACH OCCUPANCY TYPE FOR THE BUILDING. A
 MORE DETAILED COST BREAK OUT ESTIMATE WILL BE REQUIRED
 FOR THE VERTICAL CONSTRUCTION PERMIT DUE TO SOME ITEMS
 THAT REQUIRE SEPARATE PERMITS. FBC AMENDMENTS 109
 SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE
 REQUIRED FOR:
 LIGHT POLES/SITE LIGHTING
 FIRE ALARM
 FIRE SPRINKLER
 LOW VOLTAGE
 ACCESS
 LANDSCAPING
 IRRIGATION
 PARKING LOT
 SWIMMING POOLS AND SPAS
 GENERATORS
 ALL OTHER ITEMS OTHER THAN BMEP
  
 6) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By jleahy Date 2022-03-07 Time 09:12 Rev Time 0.00
Received By jleahy Date 2022-03-07 Time 09:09 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2022-06-14 Cont ID  
Sent By rrossano Date 2022-06-14 Time   Rev Time 0.00
Received By rrossano Date 2022-06-14 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-04-09 Cont ID  
Sent By rrossano Date 2022-04-09 Time   Rev Time 0.00
Received By   Date 2022-04-09 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By rrossano Date 2022-02-23 Time   Rev Time  
Received By rrossano Date 2022-02-23 Time   Sent To  
Notes
2022-02-23 11:44:27NOTE UPDATE: UNDER REVIEW AS FORMAL ENGINEERING
 SUBMITTAL E22020017.
  
 THANKS,
  
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-09 Cont ID  
Sent By pleduc Date 2022-06-09 Time   Rev Time 0.00
Received By pleduc Date 2022-06-09 Time 12:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By pleduc Date 2022-02-24 Time   Rev Time 0.00
Received By pleduc Date 2022-02-18 Time 14:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 14:57 Rev Time 0.00
Received By rmcphers Date 2022-06-08 Time 06:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-04 Cont ID  
Sent By rmcdouga Date 2022-05-04 Time 09:20 Rev Time 0.00
Received By rmcdouga Date 2022-04-06 Time 11:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-17 Cont ID  
Sent By aoliver Date 2022-03-17 Time 10:06 Rev Time 0.00
Received By aoliver Date 2022-02-17 Time 08:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2022-06-10 Cont ID  
Sent By aoliver Date 2022-06-10 Time 13:48 Rev Time 0.00
Received By aoliver Date 2022-05-24 Time 16:50 Sent To  
Notes
2022-06-09 16:55:43RECEIPT MU-2022-025256 - $253,769.87 PAID
2022-05-24 16:50:415/24/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-04-20 Cont ID  
Sent By rmcdouga Date 2022-04-20 Time 16:55 Rev Time 0.00
Received By rmcdouga Date 2022-04-20 Time 16:55 Sent To  
Notes
2022-04-20 16:59:57BECAUSE THIS PERMIT NOW INCLUDES THE BUILDINGS
 SUPERSTRUCTURE THE IMPACT FEE REVIEW IS REQUIRED BEFORE
 THE PERMIT IS ISSUED. PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT:
 HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By rmcdouga Date 2022-03-07 Time 14:09 Rev Time 0.00
Received By rmcdouga Date 2022-03-07 Time 14:09 Sent To  
Notes
2022-03-07 14:10:07PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 SINCE THIS IS A FOUNDATION ONLY PERMIT, YOU MAY WISH TO
 SEND A LETTER TO THE BUILDING OFFICIAL REQUESTING THAT
 THE IMPACT FEES BE DEFERRED UNTIL THE PERMIT TO BEGIN
 VERTICAL CONSTRUCTION IS READY TO BE ISSUED.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-02-28 Time 16:03 Rev Time 0.00
Received By ccole Date 2022-02-28 Time 12:13 Sent To  
Notes
2022-02-28 16:04:07THE ARCHITECT HAS REQUESTED THAT ALL PLUMBING WORK BE
 DONE UNDER THE MAIN BUILDING PERMIT.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-07-05 Cont ID  
Sent By dbattles Date 2022-07-05 Time 11:29 Rev Time 0.00
Received By dbattles Date 2022-07-05 Time 11:29 Sent To  
Notes
2022-07-05 11:37:36PRIVATE PROVIDER INSPECTIONS.
 DOCUMENTS ADDED TO PROJECTDOX.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 14:57 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 14:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-04 Cont ID  
Sent By rmcdouga Date 2022-05-04 Time 09:19 Rev Time 0.00
Received By rmcdouga Date 2022-05-04 Time 09:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-03-08 Cont ID  
Sent By rmcdouga Date 2022-03-08 Time 17:38 Rev Time 0.00
Received By rmcdouga Date 2022-03-08 Time 17:38 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 4 Status P Date 2022-07-01 Cont ID  
Sent By rmcphers Date 2022-07-01 Time 13:09 Rev Time 0.00
Received By rmcphers Date 2022-07-01 Time 13:09 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 3 Status F Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 14:53 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 14:53 Sent To  
Notes
2022-06-30 14:53:33SEE BUILDING PLAN REVIEW

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status F Date 2022-05-03 Cont ID  
Sent By rmcdouga Date 2022-05-03 Time 10:47 Rev Time 0.00
Received By rmcdouga Date 2022-05-03 Time 10:47 Sent To  
Notes
2022-05-03 10:47:341) THE THRESHOLD ENGINEER IS REQUIRED TO SIGN AND SEAL
 THE THRESHOLD FORM. THE OWNER'S NOTARIZED SIGNATURE IS
 REQUIRED ON THE OWNER FORM. THE CONTRACTOR'S NOTARIZED
 SIGNATURE IS REQUIRED ON THE CONTRACTOR FORM.
 THIS PROJECT IS A THRESHOLD BUILDING PER FL S. S.
 553.71(7) "THRESHOLD BUILDING" MEANING ANY BUILDING
 WHICH IS GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT,
 OR WHICH HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS
 DEFINED IN THE FLORIDA BUILDING CODE WHICH EXCEEDS
 5,000 SQ. FT. IN AREA AND AN OCCUPANT CONTENT OF
 GREATER THAN 500 PERSONS.
  
 A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION
 PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL THRESHOLD BUILDING INSPECTION PLAN IS
 TO PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES
 SO THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS.
  
 B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5)
 FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY
 THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED
 TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED
 AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED
 BEFORE PERMIT ISSUANCE WILL TAKE PLACE.
  
 C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF
 RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM
 BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS
 AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633 FLORIDA STATUTES.
  
 D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN
 INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
  
 E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
  
 F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE,
 PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING
 ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE
 APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR
 PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN
 COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR
 THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE
 IN BLACK & WHITE.
  
 G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES,
 PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT
 AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING
 DOCUMENTS BY THE CONTRACTOR.
  
 H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL
 BUILDING INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6
 MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY.
  
 I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR
 THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS
 REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL,
 APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND
 CEILINGS.
  
 J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL
 BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER
 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING
 THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS.
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By rmcdouga Date 2022-03-07 Time 14:05 Rev Time 0.00
Received By rmcdouga Date 2022-03-07 Time 14:05 Sent To  
Notes
2022-03-07 14:13:49THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN
 (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION
 PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5)
 FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY
 THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED
 TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED
 AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED
 BEFORE PERMIT ISSUANCE WILL TAKE PLACE.
  
 C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF
 RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM
 BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS
 AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633 FLORIDA STATUTES.
  
 D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN
 INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
  
 E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
  
 F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE,
 PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING
 ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE
 APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR
 PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN
 COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR
 THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE
 IN BLACK & WHITE.
  
 G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES,
 PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT
 AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING
 DOCUMENTS BY THE CONTRACTOR.
  
 H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL
 BUILDING INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6
 MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY.
  
 I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR
 THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS
 REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL,
 APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND
 CEILINGS.
  
 J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL
 BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER
 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING
 THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS.
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-06-27 Cont ID  
Sent By aaponte Date 2022-06-27 Time 19:18 Rev Time 0.00
Received By aaponte Date 2022-06-27 Time 19:18 Sent To  
Notes
2022-06-27 19:19:44PROVISO: DROP OFF AREAS CANNOT EXCEED A 2% CROSS SLOPE.

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-22 Cont ID  
Sent By aaponte Date 2022-04-22 Time 14:44 Rev Time 0.00
Received By aaponte Date 2022-04-22 Time 14:44 Sent To  
Notes
2022-04-22 14:44:351. NO WALLS SHALL ENCLOSE THE STORAGE AREA LOCATED
 SOUTH OF THE CAFE OPEN SPACE OR THE STORAGE SHALL BE
 COUNTED AS PART OF THE GBA.
 2. PLEASE CLARIFY ENCLOSURE PROPOSED FOR THE SERVICE
 CORRIDOR IT NEEDS TO BE GENERALLY OPEN TOWARDS THE
 GARAGE AND NOT UNDER AC AS IT IS NOT COUNTED AS PART OF
 THE GBA.
 3. A TRENCH DRAIN IS PROPOSED ON THE DRIVEWAY ON
 BANYAN. SUCH DRAIN IS WITHIN THE SIDEWALK/PEDESTRIAN
 PATH OF TRAVEL. PLEASE EXPLORE THE POSSIBILITY OF
 MOVING THE DRAIN TO THE EDGE OF BUILDING. A SIMILAR
 SITUATION IS HAPPENING WITH THE PROPOSED TRENCH DRAIN
 AT THE EAST END OF THE ALLEY. PLEASE MOVE IT WEST OF
 THE 301 CLEMATIS FA?ADE BUILDING SO IT IS OUTSIDE THE
 PEDESTRIAN PATH OF TRAVEL.
 4. FACADE OF CAFE AREA IS SUBSTANTIALLY DIFFERENT THAN
 DAC APPROVAL. TO REDUCE THE CHANGES PLEASE RESTORE THE
 ORIGINAL FEATURE METAL BATTENS, WOODGRAIN FINISH
 ORIGINALLY PROPOSED FOR THE BACK WALL OF THE OUTDOOR
 SEATING.
 5. PARKING ON GROUND LEVEL SHALL BE STRIPED ACCORDING
 TO CITY STANDARD. TANDEM PARKING IS PERMITTED IF VALET
 OPERATION IS OFFERED.
 6. PLEASE CONFIRM NO EXPOSED PIPES UNDER THE GARAGE
 SLABS WILL BE VISIBLE FROM THE STREET.
 7. RETRACTABLE EN-FOLD AWNING SYSTEM OVER ALLEY WILL
 REQUIRE AN AERIAL EASEMENT FROM THE CITY.
 8. MECHANICAL LOUVERS SHALL BE PAINTED THE SAME COLOR
 THAN THE ADJACENT FA?ADE WALL.
 9. PLEASE DIMENSION THE PARKING SPACES TO CONFIRM
 COMPLIANCE WITH MINIMUM DIMENSIONS, AND CONFIRM
 STRIPING IS PROPERLY DONE FOR ALL SPACES (CHECK
 STRIPING FOR SPACE 187, 159, 220, 219, 251, 263)
 10. PLEASE PROVIDE SPECS FOR THE BIKE RACKS ALONG THE
 BUILDING FRONTAGE AND THE RACKS INSIDE THE PARKING
 GARAGE.
 11. A SEPARATE LANDSCAPE PERMIT SHALL BE SUBMITTED FOR
 APPROVAL.
 12. A SEPARATE ELECTRIC PERMIT SHALL BE SUBMITTED FOR
 THE DECORATIVE LIGHTING ALONG THE ROW. DECORATIVE
 LIGHTING SHALL MATCH THE DOWNTOWN STANDARD.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-03-16 Cont ID  
Sent By aaponte Date 2022-03-16 Time 15:18 Rev Time 0.00
Received By aaponte Date 2022-03-16 Time 15:18 Sent To  
Notes
2022-03-16 15:48:32NOTES FOR BUILDING PERMIT:
 1. NO WALLS SHALL ENCLOSE THE STORAGE AREA LOCATED
 SOUTH OF THE CAFE OPEN SPACE OR THE STORAGE SHALL BE
 COUNTED AS PART OF THE GBA.
 2. PLEASE CLARIFY ENCLOSURE PROPOSED FOR THE SERVICE
 CORRIDOR.
 3. A TRENCH DRAIN IS PROPOSED ON THE DRIVEWAY. SUCH
 DRAIN IS WITHIN THE SIDEWALK/PEDESTRIAN PATH OF TRAVEL.
 MOVE DRAIN TO THE EDGE OF BUILDING OR TO THE END OF
 DRIVEWAY APRON.
 4. UPDATE PLANTING AREAS TO REFLECT SITE PLAN APPROVAL
 SET.
 5. PLEASE ALIGN THE PATH OF PEDESTRIAN TRAVEL FOR THE
 PROPERTY ON THE WEST SIDE OF THE PROJECT WITH YOURS.
 IDENTIFY IF THE PLANTING AREA ADJACENT TO THE NW STAIR
 IS ENCROACHING IN TO THE PATH OR NOT.
 6. FACADE OF CAFE AREA IS SUBSTANTIALLY DIFFERENT THAN
 DAC APPROVAL. PLEASE EXPLAIN CHANGES.
 7. PLEASE CLEARLY IDENTIFY THE NEW CANOPIES PROPOSED IN
 SEVERAL LOCATIONS. IF ENCROACH INTO THE ROW AN EASEMENT
 WILL BE REQUIRED.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.