Plan Review Stops For Permit 22020439 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-02 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-02 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-04-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-18 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-18 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-05 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-05 |
Time |
08:15 |
Sent To |
|
|
Notes |
2022-04-05 12:34:55 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL2533-R26 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: COVER SHEET | | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE | | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL | | INFORMATION ABOUT THE PRODUCT). | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-02-10 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-10 |
Time |
07:53 |
Sent To |
|
|
Notes |
2022-02-10 12:35:26 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R9 SELECTED OPTION FOR SYSTEM NO W-5; | | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PRODUCT | | APPROVAL FL16709-R9 WILL NOT SATISFY EXPOSURE CATEGORY | | D ENCLOSED AREAS WITHOUT USING INSULATION OR PROVIDING | | ENGINEERED ENHANCED NAILING. | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE METAL TO BE USED. | | 3. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S). FLAT/LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-02 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-22 |
Time |
07:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-04-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-18 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-14 |
Time |
08:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-05 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-31 |
Time |
09:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-02-10 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-09 |
Time |
07:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-04-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-04-25 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-04-25 |
Time |
13:12 |
Sent To |
|
|
Notes |
2022-04-25 13:26:45 | HARD COPY WIND LOAD ENGINEERING CALCULATIONS WITH | | ORIGINAL SEAL AND WET SIGNATURE. JG, |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-04-18 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-18 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-18 |
Time |
07:56 |
Sent To |
|
|
Notes |
2022-04-18 12:14:30 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE | | ORIGINAL DOCUMENTS. SECOND REQUEST. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-04-05 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-05 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-05 |
Time |
12:14 |
Sent To |
|
|
Notes |
2022-04-05 12:35:31 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE | | ORIGINAL DOCUMENTS. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|