Plan Review Details - Permit 22020406
Plan Review Stops For Permit 22020406
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-05-23 Cont ID  
Sent By cpuell Date 2022-05-23 Time 09:44 Rev Time 0.00
Received By cpuell Date 2022-05-23 Time 09:44 Sent To  
Notes
2022-05-23 09:45:28ADDRESS CHANGED TO 292 SUMMA ST, UPDATED PERMIT AND
 ATTACHED LETTER.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-14 Cont ID  
Sent By cpuell Date 2022-02-14 Time 12:31 Rev Time 0.00
Received By cpuell Date 2022-02-14 Time 12:31 Sent To  
Notes
2022-02-14 12:32:11PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON
 THE GROUND FLOOR FALL IN LINE WITH THE CITY'S ROAD
 CENTER LINES. PLEASE CONTACT [email protected] OR CALL
 561-805-6659 TO WORK ON THE READDRESSING ISSUES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-08-16 Cont ID  
Sent By cthroop Date 2022-08-16 Time 12:37 Rev Time 0.00
Received By cthroop Date 2022-08-16 Time 12:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-08-04 Cont ID  
Sent By cthroop Date 2022-08-04 Time 14:30 Rev Time 0.00
Received By cthroop Date 2022-08-04 Time 14:30 Sent To  
Notes
2022-08-04 14:32:42PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: PROVISO ON PLAN PAGE A-100: A SEPERATE PERMIT
 IS REQUIRED FOR THE PERGOLA. CT
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1.
  
 2.
  
 3. PROVIDE A SITE DRAINAGE PLAN WITH A BOUNDARY LINE
 SURVEY PER FBC R401.3 (NOT ADDRESSED)
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 4. PROVIDE A SOILS REPORT. (NOT ADDRESSED)
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOILS CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 5.
  
 6.
  
 7.
  
  
 7.
  
 8.
  
 9.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-07-27 Cont ID  
Sent By cthroop Date 2022-07-27 Time 09:08 Rev Time 0.00
Received By cthroop Date 2022-07-27 Time 06:10 Sent To  
Notes
2022-07-27 09:14:25PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: PROVISO ON PLAN PAGE A-100: A SEPERATE PERMIT
 IS REQUIRED FOR THE PERGOLA. CT
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1.
  
 2. THE PLAN SHEET LABLED SITE PLAN IS A COPY OF THE
 LANDSCAPE PLAN L2.0. (NOT ADDRESSED)
 PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY. IDENTIFY
 LOCATION OF WORK.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDRY LINE SURVEY.
  
 3. PROVIDE A SITE DRAINAGE PLAN WITH A BOUNDARY LINE
 SURVEY PER FBC R401.3 (NOT ADDRESSED)
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 4. PROVIDE A SOILS REPORT. (NOT ADDRESSED)
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOILS CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 5. PROVIDE THE FINISH FLOOR ELEVATION NON-FLOOD ZONE.
 (NOT ADDRESSED)
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 6.
  
 7. PLACE THE CEILING AND WALL INSULATION R VALUE ON THE
 PLANS. (NOT ADDRESSED)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 7. PROVIDE CIVIL DRAWINGS. (NOT ADDRESSED)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 8. PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVAL OR MIAMI-DADE NOA, APPROVED UNDER THE 2020
 FBC, FOR THE PROPOSED DOORS. (NOT ADDRESSED)
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 9.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By cthroop Date 2022-05-10 Time 14:28 Rev Time 0.00
Received By cthroop Date 2022-05-10 Time 10:54 Sent To  
Notes
2022-05-10 14:40:32PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: PROVISO ON PLAN PAGE A-100: A SEPERATE PERMIT
 IS REQUIRED FOR THE PERGOLA. CT
  
 1. PROVIDE A COVER SHEET. INCLUDE BUILDING DATA AND
 DESIGN CRITERIA.
 PROVIDE PROJECT DATA/DESIGN PARAMETERS:
  
 PROJECT DATA: 1&2 FAMILY DWELLING UNIT
  OCCUPANCY CLASSIFICATION R3 SFR
  SCOPE OF WORK
  
 DESIGN PARAMETERS: 2020 FBC EXISTING BUILDING
  2020 FBC RESIDENTIAL
  2017 NEC
  
 CLASSIFICATION OF WORK:
 BUILDING CLASSIFICATION: VB
 EXPOSURE CLASSIFICATION:
 RISK CATEGORY:
  
 MEAN ROOF HEIGHT: STATE MRH ON ELEVATION PLAN PAGE.
  
 EXISTING UNDER AIR: /SF
 EXISTING COVERED: /SF
 NEW UNDER AIR: /SF
 NEW COVERED: /SF
  
 TOTALS: UNDER AIR /SF
  COVERED /SF
  
 SITE SPECIFIC DESIGN WIND LOADS PER:
 FBC RESIDENTIAL CHPT. 3
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 -OR-
  
 ASCE 7-16 (VULT 170MPH 3 SEC GUST / VASD 132MPH)
  
  
 DESIGN WIND PRESSURES:
 WINDOWS AND DOORS ? ZONE 4 INT. / ZONE 5 CORNER
 (POSITVE/NEGATIVE)
 ROOF ? ZONE 1 (FIELD), ZONE 2 (EDGE), ZONE 3 (CORNERS)
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 2. THE PLAN SHEET LABLED SITE PLAN IS A COPY OF THE
 LANDSCAPE PLAN L2.0.
 PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY. IDENTIFY
 LOCATION OF WORK.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDRY LINE SURVEY.
  
 3. PROVIDE A SITE DRAINAGE PLAN WITH A BOUNDARY LINE
 SURVEY PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 4. PROVIDE A SOILS REPORT.
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOILS CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 5. PROVIDE THE FINISH FLOOR ELEVATION NON-FLOOD ZONE
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 6. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 PROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1. 1.SECTIONS R401 THROUGH R404.
 2. 2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 7. PLACE THE CEILING AND WALL INSULATION R VALUE ON THE
 PLANS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 7. PROVIDE CIVIL DRAWINGS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 8. PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVAL OR MIAMI-DADE NOA, APPROVED UNDER THE 2020
 FBC, FOR THE PROPOSED DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 9. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY FOAM
 INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2022-06-23 Cont ID  
Sent By fgiaquin Date 2022-06-23 Time 20:06 Rev Time 0.00
Received By fgiaquin Date 2022-06-23 Time 20:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-08 Cont ID  
Sent By fgiaquin Date 2022-03-08 Time 23:30 Rev Time 0.00
Received By fgiaquin Date 2022-03-08 Time 22:53 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By rwbrown Date 2022-06-13 Time 12:31 Rev Time 0.00
Received By rwbrown Date 2022-06-13 Time 12:31 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2022-02-22 Cont ID  
Sent By rwbrown Date 2022-02-22 Time 13:11 Rev Time 0.00
Received By rwbrown Date 2022-02-22 Time 13:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-08-16 Cont ID  
Sent By lmarchan Date 2022-08-16 Time 12:54 Rev Time 0.00
Received By lmarchan Date 2022-08-14 Time 09:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-04 Cont ID  
Sent By vbroglia Date 2022-08-04 Time 15:26 Rev Time 0.00
Received By vbroglia Date 2022-07-30 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-27 Cont ID  
Sent By cthroop Date 2022-07-27 Time 09:14 Rev Time 0.00
Received By cthroop Date 2022-06-10 Time 11:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-10 Cont ID  
Sent By cthroop Date 2022-05-10 Time 14:40 Rev Time 0.00
Received By cthroop Date 2022-02-16 Time 08:01 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-08-26 Cont ID  
Sent By lmarchan Date 2022-08-26 Time 14:45 Rev Time 0.00
Received By lmarchan Date 2022-08-16 Time 12:54 Sent To  
Notes
2022-08-25 15:01:55RECEIPT MU-2022-038439 - $2345.73 PAID LEM
2022-08-16 12:54:238/16/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By cthroop Date 2022-05-10 Time 11:51 Rev Time 0.00
Received By cthroop Date 2022-05-10 Time 10:54 Sent To  
Notes
2022-05-10 11:52:07IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-07-07 Cont ID  
Sent By medwards Date 2022-07-07 Time 17:25 Rev Time 0.00
Received By medwards Date 2022-07-07 Time 17:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-02 Cont ID  
Sent By medwards Date 2022-03-02 Time 06:47 Rev Time 0.00
Received By medwards Date 2022-03-02 Time 06:47 Sent To  
Notes
2022-03-02 06:48:071ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22020407
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC RES R402
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC RES R403.7
  
 3) PLEASE SHOW THE ENERGY CALCULATIONS FOR THE GARAGE
 AS THIS IS NOT TYPICALLY A CONDITIONED SPACE. FBC RES
 R402.1
  
 4) IT APPEARS THAT THE DRYER EXHAUST FROM BOTH DRYERS
 IN THE LAUNDRY AT THE GARAGE ARE RUNNING INTO ONE 4
 INCH DUCT ABOVE THE CEILING AND GOING THRU THE ROOF.
 PLEASE SHOW THAT EACH DRYER IS GOING SEPARATELY TO THE
 OUTDOORS OR PROVIDE MANUFACTURE?S INSTALLATION
 INSTRUCTIONS SHOWING THIS METHOD. FBC RES M1502.3
  
 5) PLEASE PROVIDE A BATH EXHAUST FAN OR SHOW THE
 WINDOWS MEET FBC RES R303.3 IN THE 2ND STORY SHOWER
 AREAS.
  
 6) PLEASE SHOW THE CONDENSATE DRAIN AND TERMINATION
 LOCATION. FBC RES M1411.3
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By rwbrown Date 2022-06-13 Time 12:36 Rev Time 0.00
Received By rwbrown Date 2022-06-13 Time 12:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-02-22 Cont ID  
Sent By rwbrown Date 2022-02-22 Time 13:06 Rev Time 0.00
Received By rwbrown Date 2022-02-22 Time 13:03 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-05-10 Cont ID  
Sent By cthroop Date 2022-05-10 Time 14:26 Rev Time 0.00
Received By cthroop Date 2022-05-10 Time 10:54 Sent To  
Notes
2022-05-10 14:27:17PROVISO ON PLAN PAGE S1.2: A SEPERATE ROOFING PERMIT IS
 REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-08-16 Cont ID  
Sent By cthroop Date 2022-08-16 Time 15:35 Rev Time 0.00
Received By cthroop Date 2022-08-16 Time 15:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-08-16 Cont ID  
Sent By cthroop Date 2022-08-16 Time 12:40 Rev Time 0.00
Received By cthroop Date 2022-08-16 Time 12:37 Sent To  
Notes
2022-08-16 12:43:43SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 4TH REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. COVER LETTER SUBMITTED IS ONLY FOR ARCHITECTURAL
 PLANS.
  
 2. COVER LETTER REQUIRES A VALID DIGITAL SIGNATURE.
  
 3. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-08-04 Cont ID  
Sent By cthroop Date 2022-08-04 Time 14:50 Rev Time 0.00
Received By cthroop Date 2022-08-04 Time 14:50 Sent To  
Notes
2022-08-04 14:50:52PER CONVERSATION WITH CONTRACTOR.DESIGNER TO SUBMIT
 COVER PAGE OF APPROVED PLANS. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-07-27 Cont ID  
Sent By cthroop Date 2022-07-27 Time 09:04 Rev Time 0.00
Received By cthroop Date 2022-07-27 Time 06:10 Sent To  
Notes
2022-07-27 09:04:58SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 2ND REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By cthroop Date 2022-05-10 Time 14:25 Rev Time 0.00
Received By cthroop Date 2022-05-10 Time 10:54 Sent To  
Notes
2022-05-10 14:26:32SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
  
  
  
2022-03-02 06:50:07THE MECHANICAL SHEETS WILL NEED THE DIGITAL SIGNATURE
 OF THE DESIGNER. ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-08-04 Cont ID  
Sent By vbroglia Date 2022-08-04 Time 15:26 Rev Time 0.00
Received By vbroglia Date 2022-08-04 Time 15:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-06-21 Cont ID  
Sent By vbroglia Date 2022-06-21 Time 11:25 Rev Time 0.00
Received By vbroglia Date 2022-06-21 Time 11:25 Sent To  
Notes
2022-06-21 11:26:336/21/2022 FAILED
  
 PLEASE ADDRESS PERVIOUS COMMENTS TO ALLOW STAFF TO MOVE
 FORWARD
  
 VALENTINA BROGLIA
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By vbroglia Date 2022-02-23 Time 13:59 Rev Time 0.00
Received By vbroglia Date 2022-02-23 Time 13:59 Sent To  
Notes
2022-02-23 14:15:202/23/2022 **** FAILED ****
  
 SEPARATE PERMIT REQUIRED FOR LANDSCAPING, MECHANICAL,
 FENCE/WALLS, ACCESSORY STRUCTURES, POOLS AND DRIVEWAYS
  
 PLEASE APPLY FOR A LANDSCAPE PERMIT AND OBTAIN A
 LANDSCAPE PERMIT NUMBER,THIS WILL ALLOW STAFF TO MOVE
 FORWARD WITH CURRENT PERMIT
  
 PLEASE SHOW A SITE PLAN THAT PROVIDES THE SETBACKS OF
 THE PROJECT TO THE PROPERTY LINE AND ELEVATIONS ARE TO
 SHOW HEIGHT MEASURE FROM GRADE TO THE MEAN OF THE ROOF,
 MAX. HEIGHT IS 30 FEET AND ALLOWS TO EXCEED 10 PERCENT
 FOR ARCHITECTURAL FEATURES.
  
 NOTE: SECOND RESUBMITTAL MAY BE SUBJECTED TO ADDITIONAL
 COMMENTS
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved