Plan Review Stops For Permit 22020279 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-02-17 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-02-17 |
Time |
10:47 |
Sent To |
|
|
Notes |
2022-02-17 10:48:08 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2022-04-01 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-01 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-04-01 |
Time |
07:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2022-03-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-29 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-29 |
Time |
08:11 |
Sent To |
|
|
Notes |
2022-03-29 14:07:28 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL16709-R9 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO | | INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN | | BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE | | BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY. | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R9 SELECTED SYSTEM NO W-3; EXPOSURE | | (D); ENCLOSURE (OPEN); ROOF HEIGHT (15 H < 20); | | ULTIMATE WIND SPEED (180), IS NOT CORRECT. THE CORRECT | | ULTIMATE WIND SPEED (170) & ROOF HEIGHT H < 15; SELECT | | CORRECT OPTIONS. | | 3. SUBMITTED PRODUCT APPROVAL FL27076-R1; MIAMI-DADE | | COUNTY NOA 18-0409.06 SELECTED SYSTEM E(1) IS APPROVED | | FOR USE AS A BASE SHEET ONLY IN ROOF TILE APPLICATIONS. | | PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT (CAP | | SHEET) TO BE USED. INCLUDE COVER PAGE, EVALUATION | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. NOTE: | | SYSTEM NUMBER E(4) OF THE SUBMITTED PRODUCT APPROVAL | | CAN BE USED IF USING ADHESIVE SET TILE APPLICATION WITH | | AN APPROVED ADHESIVE. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-24 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-24 |
Time |
07:51 |
Sent To |
|
|
Notes |
2022-03-24 11:43:26 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | FL16709-R9 IS INCOMPLETE, PROVIDE THE FOLLOWING | | ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO | | INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN | | BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE | | BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY. | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R9 SELECTED SYSTEM NO W-3; EXPOSURE | | (D); ENCLOSURE (OPEN); ROOF HEIGHT (15 H < 20); | | ULTIMATE WIND SPEED (180), IS NOT CORRECT. THE CORRECT | | ULTIMATE WIND SPEED (170) & ROOF HEIGHT H < 15; SELECT | | CORRECT OPTIONS. | | 3. SUBMITTED PRODUCT APPROVAL FL27076-R1; MIAMI-DADE | | COUNTY NOA 18-0409.06 SELECTED SYSTEM E(1) IS APPROVED | | FOR USE AS A BASE SHEET ONLY IN ROOF TILE APPLICATIONS. | | PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT (CAP | | SHEET) TO BE USED. INCLUDE COVER PAGE, EVALUATION | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. NOTE: | | SYSTEM NUMBER E(4) OF THE SUBMITTED PRODUCT APPROVAL | | CAN BE USED IF USING ADHESIVE SET TILE APPLICATION WITH | | AN APPROVED ADHESIVE. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-21 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-21 |
Time |
07:56 |
Sent To |
|
|
Notes |
2022-03-21 10:11:18 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED FLAT/LOW SLOPE ROOF | | SYSTEM TO BE USED. INCLUDE COVER PAGE, EVALUATION | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. PLEASE | | NOTE THIS IS A CATEGORY D AREA. | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. | | 3. SUBMITTED PRODUCT APPROVAL FL27076-R1; MIAMI-DADE | | COUNTY NOA 18-0409.06 SELECTED SYSTEM E(1) IS APPROVED | | FOR USE AS A BASE SHEET ONLY IN ROOF TILE APPLICATIONS. | | PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT (CAP | | SHEET) TO BE USED. INCLUDE COVER PAGE, EVALUATION | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. NOTE: | | SYSTEM NUMBER E(4) OF THE SUBMITTED PRODUCT APPROVAL | | CAN BE USED IF USING ADHESIVE SET TILE APPLICATION WITH | | AN APPROVED ADHESIVE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-03-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-03 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-03 |
Time |
11:31 |
Sent To |
|
|
Notes |
2022-03-03 13:56:47 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 | | (FL27076-R1) COVERS MULTIPLE PRODUCTS & APPROVED | | ASSEMBLIES: SYSTEMS E(1) THROUGH E(4). SELECT PRODUCT & | | SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | APPROVAL DRAWINGS. SECOND REQUEST. | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | MEAN ROOF HEIGHT(S). SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-02-17 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-17 |
Time |
07:52 |
Sent To |
|
|
Notes |
2022-02-17 11:38:14 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED STATE OF FLORIDA PRODUCT | | APPROVAL FL17152-R4 COVERS MULTIPLE ATTACHMENT SYSTEMS; | | ADHESIVE AND MORTAR SET. SELECT SYSTEM TO BE USED. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 | | (FL27076-R1) COVERS MULTIPLE PRODUCTS & APPROVED | | ASSEMBLIES: SYSTEMS E(1) THROUGH E(4). SELECT PRODUCT & | | SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | APPROVAL DRAWINGS. | | 3. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | MEAN ROOF HEIGHT(S). | | 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE METAL TO BE USED. (FL5374-R6) | | 5. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | HIP & RIDGE TILE ADHESIVE TO BE USED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-04-01 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-04-01 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-31 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-03-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-29 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-28 |
Time |
06:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-24 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-23 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-03-21 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-21 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-16 |
Time |
10:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-03 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-23 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-17 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-02-17 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-16 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|