Plan Review Details - Permit 22020184
Plan Review Stops For Permit 22020184
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-05-27 Cont ID  
Sent By rwbrown Date 2022-05-27 Time 06:50 Rev Time 0.00
Received By rwbrown Date 2022-05-27 Time 06:50 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-02-12 Cont ID  
Sent By abelisle Date 2022-02-12 Time 12:14 Rev Time 0.00
Received By abelisle Date 2022-02-12 Time 11:34 Sent To  
Notes
2022-02-12 12:18:392ND REVIEW FBC-2020 RES. GAS
 PERMIT- 22020184
 2/12/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 PLEASE ADDRESS PREVIOUS PLANS EXAMINERS COMMENTS.
  
 1) THIS APPEARS TO BE A NEW INSTALLATION OF A GAS-FIRED
 TANKLESS WATER HEATER AND NOT A REPLACEMENT. WPB
 BUILDING DEPT. RECORDS TO NOT SHOW A PREVIOUS GAS
 PERMIT WAS ISSUED FOR A TANKLESS WATER HEATER. PLEASE
 PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES ALL
 NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE
 RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO
 FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND BTU LOAD OF THE WATER HEATER AND
 OTHER EXISTING APPLIANCES.
 D) TYPE AND SIZE OF PIPING SUPPLYING THE WATER HEATER.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) OUTLET PRESSURES AT REGULATORS.
 I) PIPE SIZING TABLES.
  
 2) PROVIDE A DRAWING THAT SHOWS THE LOCATION OF THE
 WATER HEATER AND REQUIRED CLEARANCES PER MANUFACTURER'S
 SPECIFICATIONS AND SECS. G2427.8 & G2448.1 FBC RES
  
 3) IF AN ELECTRICAL OUTLET HAS TO BE INSTALLED FOR THE
 NEW TANKLESS WATER HEATER, AND ELECTRICAL PERMIT IS
 REQUIRED FOR THIS NEW ELECTRICAL WORK.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-02-08 Cont ID  
Sent By ccole Date 2022-02-08 Time 17:40 Rev Time 0.00
Received By ccole Date 2022-02-08 Time 17:10 Sent To  
Notes
2022-02-08 17:40:561ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22020184
 2/8/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THIS APPEARS TO BE A NEW INSTALLATION OF A GAS-FIRED
 TANKLESS WATER HEATER AND NOT A REPLACEMENT. WPB
 BUILDING DEPT. RECORDS TO NOT SHOW A PREVIOUS GAS
 PERMIT WAS ISSUED FOR A TANKLESS WATER HEATER. PLEASE
 PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES ALL
 NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE
 RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO
 FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND BTU LOAD OF THE WATER HEATER AND
 OTHER EXISTING APPLIANCES.
 D) TYPE AND SIZE OF PIPING SUPPLYING THE WATER HEATER.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) OUTLET PRESSURES AT REGULATORS.
 I) PIPE SIZING TABLES.
  
 2) PROVIDE A DRAWING THAT SHOWS THE LOCATION OF THE
 WATER HEATER AND REQUIRED CLEARANCES PER MANUFACTURER'S
 SPECIFICATIONS AND SECS. G2427.8 & G2448.1 FBC RES
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-27 Cont ID  
Sent By rwbrown Date 2022-05-27 Time 06:50 Rev Time 0.00
Received By rwbrown Date 2022-05-26 Time 15:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-12 Cont ID  
Sent By cpuell Date 2022-02-12 Time 14:44 Rev Time 0.00
Received By cpuell Date 2022-02-11 Time 12:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-02-08 Time   Rev Time 0.00
Received By lmarchan Date 2022-02-07 Time 08:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-05-27 Cont ID  
Sent By rwbrown Date 2022-05-27 Time 06:49 Rev Time 0.00
Received By rwbrown Date 2022-05-27 Time 06:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-02-12 Cont ID  
Sent By abelisle Date 2022-02-12 Time 12:14 Rev Time 0.00
Received By abelisle Date 2022-02-12 Time 11:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-08 Cont ID  
Sent By ccole Date 2022-02-08 Time 17:13 Rev Time 0.00
Received By ccole Date 2022-02-08 Time 17:10 Sent To  
Notes
2022-02-08 17:16:461ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22020184
 2/8/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SEC.
 105.1 WPB.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-02-08 Cont ID  
Sent By ccole Date 2022-02-08 Time 17:13 Rev Time 0.00
Received By ccole Date 2022-02-08 Time 17:13 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved