Plan Review Details - Permit 22020173
Plan Review Stops For Permit 22020173 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-05-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-13 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-13 |
Time |
07:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-03-25 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-03-25 |
Time |
08:27 |
Sent To |
|
|
Notes |
2022-03-25 08:53:49 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, THE CALCULATION SHEET INDICATES THAT | | THIS IS IN EXPOSURE "C". THIS SHOULD BE IDENTIFIED AS | | EXPOSURE "D". PLEASE CORRECT THE EXPOSURE AND | | RECALCULATE. | | NOTE: THE DIGITAL SIGNATURE ON THIS SHEET IS NOT THIRD | | PARTY VERIFIABLE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-05-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-13 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-31 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-03-25 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-03-01 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-06-01 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-06-01 |
Time |
16:34 |
Sent To |
|
|
Notes |
2022-06-01 16:35:14 | SENT TO STORAGE JLEAHY |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-05-13 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-13 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-13 |
Time |
07:31 |
Sent To |
|
|
Notes |
2022-05-13 07:34:13 | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | 1. PREVIOUS COMMENT NOT ADDRESSED, CALCULATION PAGE IS | | NOT 3R PARTY VALIDATED. THE PAGE IS A COPY OF THE | | DIGITAL SIGNATURE AND NOT THE ORIGINAL. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-03-25 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-03-25 |
Time |
08:27 |
Sent To |
|
|
Notes |
2022-03-25 08:56:02 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | SIGNATURE REVIEW DENIED: | | | | THE DIGITAL SIGNATURES ON THE CALCULATION SHEET NEEDS | | TO BE THIRD PARTY VERIFIABLE. | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |