Plan Review Details - Permit 22020132
Plan Review Stops For Permit 22020132
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-03-02 Cont ID  
Sent By cpuell Date 2022-03-02 Time 11:03 Rev Time 0.00
Received By cpuell Date 2022-03-02 Time 11:03 Sent To  
Notes
2022-03-02 11:04:23PARCEL GIVEN THE ADDRESS OF 575 LILAC CT, UPDATED
 PERMITS DOCS

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-22 Cont ID  
Sent By cpuell Date 2022-02-22 Time 16:41 Rev Time 0.00
Received By cpuell Date 2022-02-22 Time 16:40 Sent To  
Notes
2022-02-22 16:41:10AN ADDRESS NEEDS TO BE ESTABLISHED FOR THIS PROJECT.
 PLEASE PROVIDE A SURVEY AND A BLOCK AERIAL MAP SHOWING
 WHERE THE LOT IS LOCATED ON THE BLOCK. PLEASE EMAIL
 [email protected] OR CALL 561-805-6659.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-01 Cont ID  
Sent By jgomez Date 2022-07-01 Time 15:52 Rev Time 0.00
Received By jgomez Date 2022-07-01 Time 15:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-06-16 Cont ID  
Sent By jgomez Date 2022-06-16 Time 16:59 Rev Time 0.00
Received By jgomez Date 2022-06-16 Time 16:59 Sent To  
Notes
2022-06-16 17:00:22NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW
 COMMENTS
 CODE: BC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22020132
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***IMPORTANT***
 ENERGY CALCULATIONS NEED TO BE SUBMITTED AND CERTIFIED
 BY THE OWNER OR AUTHORIZED AGENT BEFORE ISSUING THE
 PERMIT.
  
 1- OK.
 2- OK.
 3- OK.
  
 ORIGINAL COMMENT:
 4-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 BC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 A)REPEAT COMMENT: ENERGY CALCULATIONS FORM R405-2020 IS
 REQUIRED TO BE CERTIFIED AT THE BOTTOM BY THE OWNER,
 THE OWNER'S ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY
 DESIGNED BY THE OWNER PRIOR TO RECEIVE THE PERMIT AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)REPEAT COMMENT. BUILDER TO SIGN AND COMPLETE THE
 ENERGY PERFORMANCE LEVEL (EL) DISPLAY CARD. SEC.
 R405.4.3 FBC- ENERGY CONSERVATION.
  
 ORIGINAL COMMENT:
 5- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY AFC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)SINGLE HUNG WINDOWS.
 B)ENTRY DOOR.
 C)GREAT ROOM SWING DOOR.
 D)ROOF SHINGLES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. CONTRACTOR TO RESPOND IF
 SUBMITTING LATER AS A DEFERRED SUBMITTAL OR IF
 SUBMITTING THEM AT RESUBMITS.
  
 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 ORIGINAL COMMENT:
 7- DRAINAGE PLAN DRAWING C-1: REVISE PROPOSED DRAINAGE
 AT THE REAR AND RIGHT HAND SIDE OF THE PROPERTY.
 SURFACE DRAINAGE CAN NOT BE DIVERTED TO ADJACENT
 PROPERTIES. DRAINAGE WATER TO BE KEPT WITHIN THE LOT OR
 DIVERTED TOWARDS THE STREET. R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY
 AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. DRAINAGE PLAN WAS NOT
 REVISED. CONTRACTOR TO RESPOND IF SUBMITTING LATER AS A
 DEFERRED SUBMITTAL OR IF SUBMITTING REVISED DRAINAGE
 PLAN AT RESUBMITS.
  
 8- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-17 Cont ID  
Sent By jgomez Date 2022-05-17 Time 11:25 Rev Time 0.00
Received By jgomez Date 2022-05-17 Time 10:19 Sent To  
Notes
2022-05-17 11:26:42NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22020132
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***IMPORTANT***
 ENERGY CALCULATIONS NEED TO BE SUBMITTED AND CERTIFIED
 BY THE OWNER OR AUTHORIZED AGENT BEFORE ISSUING THE
 PERMIT.
  
 ORIGINAL COMMENT:
 1- ROOF SHEATHING NAILING SPACING SPECIFIED ON SHEET
 S-2 DOESN'T COMPLY WITH TABLE R803.2.3.1
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 RESPONSE:
 REVISED ROOF SHEATHING NAILING SPECIFICATIONS IS
 MISSING SPECIFICATIONS FOR ROOF ZONE 2N.
  
 2- OK.
 3- OK.
  
 ORIGINAL COMMENT:
 4-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE
 CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 ORIGINAL COMMENT:
 5- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)SINGLE HUNG WINDOWS.
 B)ENTRY DOOR.
 C)GREAT ROOM SWING DOOR.
 D)ROOF SHINGLES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. CONTRACTOR TO RESPOND IF
 SUBMITTING LATER AS A DEFERRED SUBMITTAL OR IF
 SUBMITTING THEM AT RESUBMITAL.
  
 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 ORIGINAL COMMENT:
 7- DRAINAGE PLAN DRAWING C-1: REVISE PROPOSED DRAINAGE
 AT THE REAR AND RIGHT HAND SIDE OF THE PROPERTY.
 SURFACE DRAINAGE CAN NOT BE DIVERTED TO ADJACENT
 PROPERTIES. DRAINAGE WATER TO BE KEPT WITHIN THE LOT OR
 DIVERTED TOWARDS THE STREET. R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY
 AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. DRAINAGE PLAN WAS NOT
 REVISED. CONTRACTOR TO RESPOND IF SUBMITTING LATER AS A
 DEFERRED SUBMITAL OR IF SUBMITTING REVISED DRAINAGE
 PLAN AT RESUBMITAL.
  
 8- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-14 Cont ID  
Sent By jgomez Date 2022-04-14 Time 13:49 Rev Time 0.00
Received By jgomez Date 2022-04-13 Time 19:11 Sent To  
Notes
2022-04-14 13:52:08NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22020132
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***IMPORTANT***
 ENERGY CALCULATIONS NEED TO BE SUBMITTED AND CERTIFIED
 BY THE OWNER OR AUTHORIZED AGENT BEFORE ISSUING THE
 PERMIT.
  
 1- ROOF SHEATHING NAILING SPACING SPECIFIED ON SHEET
 S-2 DOESN'T COMPLY WITH TABLE R803.2.3.1
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 2- GABLE END UPLIFT DIAGRAM SHOWN ON SHEET S-2 DOESN'T
 MATCH ROOF ZONES ZONES SPECIFIED ON FIGURE R301.2(7)
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 3- PLANS DON'T PROVIDE SPECIFICATIONS SHOWING HOW
 COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR
 ROOFING UNDERLAYMENT SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE
 PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001
  
 4-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 5- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)SINGLE HUNG WINDOWS.
 B)ENTRY DOOR.
 C)GREAT ROOM SWING DOOR.
 D)ROOF SHINGLES.
  
 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 7- DRAINAGE PLAN DRAWING C-1: REVISE PROPOSED DRAINAGE
 AT THE REAR AND RIGHT HAND SIDE OF THE PROPERTY.
 SURFACE DRAINAGE CAN NOT BE DIVERTED TO ADJACENT
 PROPERTIES. DRAINAGE WATER TO BE KEPT WITHIN THE LOT OR
 DIVERTED TOWARDS THE STREET. R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY
 AMENDMENTS.
  
 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS
 UPDATED TO $154,371.00. THE PERMIT FEE BALANCE IS
 $2884.68.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By fgiaquin Date 2022-05-09 Time 19:02 Rev Time 0.00
Received By fgiaquin Date 2022-05-06 Time 21:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-14 Cont ID  
Sent By fgiaquin Date 2022-03-14 Time 21:21 Rev Time 0.00
Received By fgiaquin Date 2022-03-14 Time 20:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-01 Cont ID  
Sent By jgomez Date 2022-07-01 Time 15:52 Rev Time 0.00
Received By jgomez Date 2022-06-23 Time 15:25 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-16 Cont ID  
Sent By jgomez Date 2022-06-16 Time 17:03 Rev Time 0.00
Received By jgomez Date 2022-05-26 Time 08:06 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-17 Cont ID  
Sent By jgomez Date 2022-05-17 Time 13:11 Rev Time 0.00
Received By jgomez Date 2022-04-18 Time 15:53 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-14 Cont ID  
Sent By jgomez Date 2022-04-14 Time 14:43 Rev Time 0.00
Received By jgomez Date 2022-02-22 Time 06:16 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-07-12 Cont ID  
Sent By lmarchan Date 2022-07-12 Time 16:57 Rev Time 0.00
Received By lmarchan Date 2022-07-01 Time 15:57 Sent To  
Notes
2022-07-12 16:01:58RECEIPT MU-2022-030740 - $9968.61 PAID
2022-07-01 15:57:197/1/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-04-14 Cont ID  
Sent By jgomez Date 2022-04-14 Time 14:42 Rev Time 0.00
Received By jgomez Date 2022-04-14 Time 14:42 Sent To  
Notes
2022-04-14 14:42:53IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-03 Cont ID  
Sent By medwards Date 2022-05-03 Time 07:53 Rev Time 0.00
Received By medwards Date 2022-05-03 Time 07:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By medwards Date 2022-03-07 Time 08:56 Rev Time 0.00
Received By medwards Date 2022-03-07 Time 08:56 Sent To  
Notes
2022-03-07 08:56:261ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22020132
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC RES
 R401.2
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC RES R403.7.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-04-26 Cont ID  
Sent By rwbrown Date 2022-04-26 Time 15:00 Rev Time 0.00
Received By rwbrown Date 2022-04-26 Time 15:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By lcrespo Date 2022-02-24 Time 11:28 Rev Time 0.00
Received By lcrespo Date 2022-02-24 Time 11:28 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-07-05 Cont ID  
Sent By dbattles Date 2022-07-05 Time 10:52 Rev Time 0.00
Received By dbattles Date 2022-07-05 Time 10:52 Sent To  
Notes
2022-07-05 10:53:30APPROVED CREDENTIALS FOR PRIVATE PROVIDER INSPECTIONS.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2022-07-01 Cont ID  
Sent By jgomez Date 2022-07-01 Time 15:50 Rev Time 0.00
Received By jgomez Date 2022-07-01 Time 15:50 Sent To  
Notes
2022-07-01 15:52:011- SHINGLES NOA 20-0527.05.
 2- HIP AND RIDGE NOA 21-0112.01

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2022-06-16 Cont ID  
Sent By jgomez Date 2022-06-16 Time 17:02 Rev Time 0.00
Received By jgomez Date 2022-06-16 Time 17:02 Sent To  
Notes
2022-06-16 17:03:19ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)ROOF SHINGLES.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-05-17 Cont ID  
Sent By jgomez Date 2022-05-17 Time 12:52 Rev Time 0.00
Received By jgomez Date 2022-05-13 Time 06:46 Sent To  
Notes
2022-05-17 12:53:17ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)ROOF SHINGLES.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-04-14 Cont ID  
Sent By jgomez Date 2022-04-14 Time 14:19 Rev Time 0.00
Received By jgomez Date 2022-04-14 Time 14:19 Sent To  
Notes
2022-04-14 14:20:01ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)SINGLE HUNG WINDOWS.
 B)ENTRY DOOR.
 C)GREAT ROOM SWING DOOR.
 D)ROOF SHINGLES.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
 NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
 ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-07-01 Cont ID  
Sent By jgomez Date 2022-07-01 Time 15:50 Rev Time 0.00
Received By jgomez Date 2022-07-01 Time 15:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-06-16 Cont ID  
Sent By jgomez Date 2022-06-16 Time 17:01 Rev Time 0.00
Received By jgomez Date 2022-06-16 Time 17:00 Sent To  
Notes
2022-06-16 17:02:16SIGNATURE REVIEW:
  
 1- IT LOOKS LIKE REVISED DRAWING C-1 HAS A COPY OF THE
 DIGITAL SIGNATURE. NEED ORIGINAL DIGITAL SIGNATURE.
 CHAPTER 471 F.S.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-05-17 Cont ID  
Sent By jgomez Date 2022-05-17 Time 13:07 Rev Time 0.00
Received By jgomez Date 2022-05-17 Time 12:53 Sent To  
Notes
2022-05-17 13:10:59SIGNATURE REVIEW:
 1- DRAWING C-1 UPLOADED TO PROJECTDOX ON 04/16/22 HAS A
 COPY OF A DIGITAL SIGNATURE. ALL DRAWINGS NEED TO HAVE
 ORIGINAL SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S.
 WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH DIGITAL
 SIGNATURE OR PROVIDE HARD COPY WITH ORIGINAL SEAL AND
 SIGNATURE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-04-14 Cont ID  
Sent By jgomez Date 2022-04-14 Time 14:41 Rev Time 0.00
Received By jgomez Date 2022-04-14 Time 14:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-04-21 Cont ID  
Sent By afowlkes Date 2022-04-21 Time 14:01 Rev Time 0.00
Received By afowlkes Date 2022-04-21 Time 14:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-02-28 Cont ID  
Sent By ajvann Date 2022-02-28 Time 16:35 Rev Time 0.00
Received By afowlkes Date 2022-02-28 Time 16:27 Sent To  
Notes
2022-02-28 16:35:3202/28/22 FAILED - ADDRESS SPECIFIED IN THE SITE PLAN IS
 AN ADDRESS DIFFERENT THAN FOR THE LOT IDENTIFIED FOR
 THE PROPOSED ONE STORY HOME.
  
 ALEXANDER FOWLKES
 [email protected]
 561-822-1431
  
  