|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22011233
Plan Review Stops For Permit 22011233 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-30 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-26 |
Time |
15:24 |
Sent To |
|
|
Notes |
2022-03-26 15:25:11 | SENT CONTRACTOR EMAIL REGARDING RENDERING DISCREPANCY | | IN PDOX AND ADOBE. WIND DESIGN CRITERIA DOES NOT APPEAR | | CONSISTENTLY. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-08 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-08 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-05 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-05 |
Time |
16:26 |
Sent To |
|
|
Notes |
2022-03-05 16:27:34 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | ENGINEERING IS DESIGNED TO 70MPH, THAT IS NOT | | SUFFICIENT FOR THIS WIND ZONE, FBC B 1609. | | | | REVISE ENGINEERING ACCORDINGLY. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-03-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-03-30 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-30 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-18 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-18 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-03-30 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-11 |
Time |
07:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-05 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-02-01 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-03-30 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-30 |
Time |
13:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-18 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-18 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-03-17 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-03-17 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-03-17 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-02-04 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-02-04 |
Time |
15:59 |
Sent To |
|
|
Notes |
2022-02-08 09:12:40 | 1. SEC. 94-110 - SIGNAGE REQUIREMENTS. (B)(2) | | "...EXPOSED RACEWAYS, TRANSFORMERS, BALLASTS, AND | | ELECTRICAL WIRING ARE PROHIBITED." | | - PLEASE NOTE INDIVIDUAL LETTERS SHALL BE ATTACHED | | DIRECTLY TO THE BUILDING FACADE. IN THOSE CASES WHERE | | THE INDIVIDUAL LETTERS CANNOT BE ATTACHED DIRECTLY TO | | THE BUILDING FACADE, A SUPPORT BACK PANEL MAY BE | | ALLOWED, BUT SUCH PANEL SHALL NOT BE INTERNALLY | | ILLUMINATED. | | | | | 2022-02-04 16:09:23 | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |