Plan Review Details - Permit 22011206
Plan Review Stops For Permit 22011206 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-03-07 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-07 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-07 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-02-02 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-02 |
Time |
07:36 |
Sent To |
|
|
Notes |
2022-02-02 09:24:44 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL14672-R6 SYSTEM NO. W-27 DO NOT MEET THE | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -131.42 | | FOR EXPOSURE CATEGORY D AREAS. PROVIDE SYSTEM THAT | | MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR | | EXPOSURE CATEGORY D/PROVIDE SIGNED AND SEALED | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | SYSTEM. | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
cdecoeur |
Date |
2022-02-01 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2022-02-01 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-03-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-10 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-09 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-07 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-07 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-02-24 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-02-02 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-01 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-10 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-10 |
Time |
08:23 |
Sent To |
|
|
Notes |
2022-03-10 08:24:30 | ORIGINAL SIGNED AND SEALED ENGINEERING SIGNED BY KEITH | | LEBLANC P.E. - TO STORAGE |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-03-07 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-03-07 |
Time |
11:09 |
Sent To |
|
|
Notes |
2022-03-07 11:12:47 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE | | ORIGINAL DOCUMENTS. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |