Plan Review Stops For Permit 22011204 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-02-02 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-02-02 |
Time |
10:18 |
Sent To |
|
|
Notes |
2022-02-02 10:19:14 | ADDRESS IS SUITE 134, UPDATED PERMIT. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-01-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-01-31 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-01-31 |
Time |
12:08 |
Sent To |
|
|
Notes |
2022-01-31 12:10:52 | APPLICATION AND PLANS HAVE DIFFERENT ADDRESSES ON THEM, | | THE APPLICATION HAS 700 S ROSEMARY AVE 116 AND THE | | PLANS HAVE 700 S ROSEMARY AVE B14. PLEASE CONFIRM THE | | CORRECT ADDRESS, AND PROVIDE A SITE PLAN OR AERIAL MAP | | SHOWING THE EXACT BUILDING TO BE WORKED ON. PLEASE | | EMAIL RESPONSE TO [email protected] OR CALL 561-805-6659. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-11 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-11 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-07-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-08 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-08 |
Time |
16:55 |
Sent To |
|
|
Notes |
2022-07-08 16:57:42 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, I WAS UNABLE TO LOCATE WIND DESIGN | | CRITERIA ON THE PLAN. IF THIS IS SOMEWHERE ON THE PLAN | | AMONGST THE LARGE QUANTITY OF DESIGN RELATED TEXT, | | EMAIL A SCREEN SHOT TO ME. OTHERWISE REVISE PLAN AND | | RESUBMIT. | | | | A DOCUMENT WAS UPLOADED, THIS WAS NOT PREPARED BY THE | | ENGINEER. | | | | THE ENGINEER PROVIDED CALCULATIONS, STATES THIS IS | | EXPOSURE B. HAVE THE ENGINEER CONTACT ME TO DISCUSS, | | THIS APPEARS TO BE EXPOSURE C. THERE ARE SEVERAL LARGE | | OPEN AREAS WITHIN A FEW HUNDRED FEET OF THIS STRUCTURE. | | | | IF THE PLAN DOES NOT INCLUDE WIND DESIGN CRITERIA, AND | | OTHER DOCUMENTS (PREPARED BY THE ENGINEER) ARE PROVIDED | | RATHER THAN INCLUDING IT ON THE PLAN, BE ADVISED THAT | | IT IS POSSIBLE THOSE DOCUMENTS MAY BE MISSED. IT IS | | ADVISABLE TO INCLUDE THE WIND DESIGN CRITERIA ON THE | | PLAN FOR EVERY PERMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-05-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-14 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-05-14 |
Time |
11:22 |
Sent To |
|
|
Notes |
2022-05-14 11:23:38 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1609, I WAS UNABLE TO LOCATE WIND DESIGN | | CRITERIA ON THE PLAN. IF THIS IS SOMEWHERE ON THE PLAN | | AMONGST THE LARGE QUANTITY OF DESIGN RELATED TEXT, | | EMAIL A SCREEN SHOT TO ME. OTHERWISE REVISE PLAN AND | | RESUBMIT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2022-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-05 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-05 |
Time |
16:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-01 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-01 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-04-14 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-04-14 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-02-17 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-02-17 |
Time |
12:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-08 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-18 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-14 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-06-14 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-05-12 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-05-03 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-05-03 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-04-06 |
Time |
11:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-03-18 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-01-31 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
|
Date |
2022-05-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-14 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-05-14 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-05-03 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-05-03 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-05-03 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-02-17 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-02-17 |
Time |
12:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-06-14 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-06-14 |
Time |
16:20 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-06-14 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-05-02 |
Time |
14:11 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-05-02 |
Time |
12:01 |
Sent To |
|
|
Notes |
2022-05-02 14:11:32 | FAILED | | | | 1) THANK YOU FOR PROVIDING THE CORRECTION TO THE DEPTH | | ON THE UPDATED PAGE 1; HOWEVER, YOU DID NOT PROVIDE THE | | UPDATED PLANS SIGNED/SEALED BY THE ENGINEER. | | | | 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN | | CRITERIA REQUIRE THAT ARCADE IDENTITY SIGNS BE CENTERED | | WITHIN THE ARCADE ARCHWAY. PROVIDE DIMENSIONS TO VERIFY | | THIS REQUIREMENT. | | | | 3) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN | | CRITERIA REQUIRE ALL CONDUIT, RACEWAYS, WIRING, BALLAST | | BOXES, TRANSFORMERS, JUNCTION BOXES, BELL BOXES, POWER | | SUPPLY AND OTHER EQUIPMENT NECESSARY FOR SIGN | | CONNECTION SHALL BE CONCEALED AND NOT VISIBLE TO THE | | PUBLIC. THE WEATHERPROOF QUICK DISCONNECT MAY NOT BE | | MOUNTED TO THE OUTSIDE OF SUPPORT TUBES BUT MUST | | INSTEAD BE INSET INTO THE SUPPORT TUBE. | | | | 4) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN | | CRITERIA DO NOT LIST ACRYLIC AS AN ACCEPTABLE MATERIAL | | FOR ARCADE IDENTITY SIGNS. ALTERNATIVE MATERIALS FOR A | | SIGN MAY BE GRANTED BY CITYPLACE RETAIL IN WRITING AS A | | WAIVER I. THE PROVIDED WAIVER I ONLY PERMITTED ACRYLIC | | FOR THE BLADE SIGN. **** AN UPDATED WAIVER I APPROVAL | | LETTER WAS NOT PROVIDED. | | | | 5) THE SIGN SIZE MEETS THE ROSEMARY SQUARE TENANT SIGN | | CRITERIA. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-03-18 |
Time |
10:23 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-03-18 |
Time |
09:07 |
Sent To |
|
|
Notes |
2022-03-18 10:27:54 | FAILED | | | | 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA STATE THAT | | THE CHANNEL DEPTH IS TO BE NOW MORE THAN THREE (3) | | INCHES. THE SIGN CROSS SECTION SHOWS THAT THIS IS | | EXCEEDED. | | | | 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT AN | | ARCADE IDENTITY SIGN TO HAVE A MAXIMUM HEIGHT OF TWELVE | | FEET FROM FINISHED GRADE. THE PROPOSED SIGN EXCEEDS | | THIS HEIGHT. ALTERNATIVE VERTICAL PLACEMENT OF A SIGN | | MAY BE GRANTED BY CITYPLACE RETAIL IN WRITING AS A | | WAIVER I. | | | | 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE | | THAT ARCADE IDENTITY SIGNS BE CENTERED WITHIN THE | | ARCADE ARCHWAY. PROVIDE DIMENSIONS TO VERIFY THIS | | REQUIREMENT. | | | | 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE ALL | | CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, TRANSFORMERS, | | JUNCTION BOXES, BELL BOXES, POWER SUPPLY AND OTHER | | EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE | | CONCEALED AND NOT VISIBLE TO THE PUBLIC. THE | | WEATHERPROOF QUICK DISCONNECT MAY NOT BE MOUNTED TO THE | | OUTSIDE OF SUPPORT TUBES BUT MUST INSTEAD BE INSET IN | | THE TUBE. | | | | 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA DO NOT LIST | | ACRYLIC AS AN ACCEPTIBLE MATERIAL FOR ARCADE IDENTITY | | SIGNS. ALTERNATIVE MATERIALS FOR A SIGN MAY BE GRANTED | | BY CITYPLACE RETAIL IN WRITING AS A WAIVER I. THE | | PROVIDED WAIVER I ONLY PERMITTED ACRYLIC FOR THE BLADE | | SIGN. | | | | 6) THE SIGN SIZE MEETS THE ROSEMARY SQUARE TENANT SIGN | | CRITERIA. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|