Plan Review Details - Permit 22011077
Plan Review Stops For Permit 22011077
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-01-28 Cont ID  
Sent By cpuell Date 2022-01-28 Time 15:43 Rev Time 0.00
Received By cpuell Date 2022-01-28 Time 15:42 Sent To  
Notes
2022-01-28 15:43:16ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-08-15 Cont ID  
Sent By jgomez Date 2022-08-15 Time 17:11 Rev Time 0.00
Received By jgomez Date 2022-08-15 Time 15:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-07-08 Cont ID  
Sent By jgomez Date 2022-07-08 Time 17:15 Rev Time 0.00
Received By jgomez Date 2022-07-08 Time 11:13 Sent To  
Notes
2022-07-08 17:16:21RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22011077.
  
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY.
 CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED AT
 THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION
 BEFORE PERMIT ISSUANCE.
  
 ORIGINAL COMMENT:
 1-LOT DRAINAGE.
 PROPOSED WORK AFFECTS THE LOT DRAINAGE. PROVIDE
 DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE IS KEPT
 WITHIN THE LOT AND NOT DIVERTED TO ADJACENT PROPERTIES.
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS
 AND SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 2- OK.
  
 3-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)METAL SHINGLES. PROVIDE COMPLETE AND CURRENT APPROVED
 PRODUCT APPROVAL. NEED COMPLETE FLORIDA PRODUCT
 APPROVAL, INCLUDING FLORIDA PRODUCT APPROVAL COVER PAGE
 SHOWING THE CURRENT CODE OR MIAMI DADE NOA.
 IF NONE OF THESE OPTIONS IS AVAILABLE, THEN
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL BY
 SUBMITTING COMPLETE ENGINEERING SIGNED AND SEALED
 DRAWINGS FOR BUILDING OFFICIAL APPROVAL. FAC
 61G20-3.001.
  
 RESPONSE:
 (1)TWO DIFFERENT PRODUCT APPROVALS WERE SUBMITTED.
 SUBMIT EITHER A COMPLETE MIAMI DADE NOA OR A COMPLETE
 FLORIDA PRODUCT APPROVAL INCLUDING THE COVER PAGE THAT
 CORRESPONDS TO THE INFORMATION SUBMITTED.
  
 (2) CLEARLY MARK ON PRODUCT APPROVAL WHICH METAL
 ROOFING FASTENING OPTION IS GOING TO BE USED. NEED THIS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES FOR ALL
 ROOF ZONES.
  
 ORIGINAL COMMENT:
 B)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO AVOID DELAYS/CONFLICTS).
  
 RESPONSE:
 REPEAT COMMENT. SIZE OF MULLION WAS NOT IDENTIFIED ON
 THE PRODUCT APPROVAL.
  
 ORIGINAL COMMENT:
 C)INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. PRODUCT APPROVAL FOR INSWING DOOR AS
 SHOWN ON PLANS WAS NOT SUBMITTED.
  
 D)OK.
  
 ORIGINAL COMMENT:
 E)STORAGE EXTERIOR DOOR AS SHOWN ON PLANS. OK. BUT NEED
 FLORIDA PRODUCT APPROVAL COVER PAGE.
  
 RESPONSE:
 PARTIALLY DONE. DRAWINGS SUBMITTED BUT FLORIDA PRODUCT
 APPROVAL COVER PAGE WAS NOT SUBMITTED.
 NOTE: THE FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE
 IT SHOWS IF PRODUCT IS APPROVED AND CURRENT CODE IN
 EFFECT.
  
 F)OK.
  
 ORIGINAL COMMENT:
 G)UNDERLAYMENT SPECIFIED ON PLANS FOR METAL SHINGLES.
  
 RESPONSE:
 PARTIALLY DONE. INFORMATION SUBMITTED IS MISSING
 FLORIDA PRODUCT APPROVAL COVER PAGE.
 NOTE: THE FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE
 IT SHOWS IF PRODUCT IS APPROVED AND CURRENT CODE IN
 EFFECT.
  
 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 5- WIND RESISTANCE OF EXTERIOR SOFFITS: ENGINEER OF
 RECORD TO PROVIDE COMPLETE DETAILS AND SPECIFICATIONS
 FOR THE SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH
 SEC. R704 FBC-RESIDENTIAL.
 NOTE: PLANS SPECIFY T & G WOOD CEILING ALT. W.L. &
 STUCCO. PROVIDE COMPLETE DETAIL/SPECS FOR ALT. W.L. &
 STUCCO SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH WIND
 RESISTANCE.
  
 RESPONSE;
 ENGINEER OF RECORD NEEDS TO SPECIFY FASTENING
 SPECIFICATIONS. CITING TABLE FROM THE CODE IS NOT
 ALLOWED. SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 6- PROVIDE ICC EVALUATION REPORT FOR THE ICYNENE R-20
 INSULATION TO VERIFY COMPLIANCE WITH SEC. R316
 FBC-RESIDENTIAL.
 NOTE: ENGINEER TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 RESPONSE:
 REPEAT COMMENT. NOT SUBMITTED.
  
 7- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-23 Cont ID  
Sent By jgomez Date 2022-03-23 Time 15:38 Rev Time 0.00
Received By jgomez Date 2022-03-23 Time 11:07 Sent To  
Notes
2022-03-23 15:42:18RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22011077.
  
 NOTE:
 ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 NOTE:
 LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING.
 SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1-LOT DRAINAGE
 1- PROPOSED WORK AFFECTS THE LOT DRAINAGE. PROVIDE
 DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE IS KEPT
 WITHIN THE LOT AND NOT DIVERTED TO ADJACENT PROPERTIES.
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS
 AND SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2-ENERGY CALCULATIONS SUBMITTED:
 NOTE: THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE.
 ENERGY CALCULATIONS ARE NOT REQUIRED. BUT IF APPLICANT
 WANTS THEM TO BE PART OF THE CONSTRUCTION DOCUMENTS,
 THEN REVISE THEM AS FOLLOWS:
  
 A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE
 CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)A/C AREA SPECIFIED ON PAGE 1 DOESN'T MATCH AREA
 SPECIFIED ON PLANS. REVISE AS REQUIRED TO MATCH.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 C) DOORS INFORMATION SPECIFIED ON PAGE 3 DOESN'T MATCH
 PLANS AND PRODUCT APPROVALS. REVISE AS REQUIRED TO
 MATCH. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
 NOTE: DOORS TO BE CONSIDERED ARE THE ONES SEPARATING
 A/C AREA FROM NON A/C AREAS.
  
 D) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 3-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL SHINGLES. PROVIDE COMPLETE AND CURRENT APPROVED
 PRODUCT APPROVAL. NEED COMPLETE FLORIDA PRODUCT
 APPROVAL, INCLUDING FLORIDA PRODUCT APPROVAL COVER PAGE
 SHOWING THE CURRENT CODE OR MIAMI DADE NOA.
 IF NONE OF THESE OPTIONS IS AVAILABLE, THEN
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL BY
 SUBMITTING COMPLETE ENGINEERING SIGNED AND SEALED
 DRAWINGS FOR BUILDING OFFICIAL APPROVAL. FAC
 61G20-3.001.
  
 B)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO AVOID DELAYS/CONFLICTS).
  
 C)INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 D)GARAGE EXTERIOR SWING DOOR AS SHOWN ON PLANS.
  
 E) STORAGE EXTERIOR DOOR AS SHOWN ON PLANS.
  
 F)CABANA BATH DOOR AS SHOWN ON PLANS.
  
 G) UNDERLAYMENT SPECIFIED ON PLANS FOR METAL SHINGLES.
  
 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 5- WIND RESISTANCE OF EXTERIOR SOFFITS: ENGINEER OF
 RECORD TO PROVIDE COMPLETE DETAILS AND SPECIFICATIONS
 FOR THE SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH
 SEC. R704 FBC-RESIDENTIAL.
 NOTE: PLANS SPECIFY T & G WOOD CEILING ALT. W.L. &
 STUCCO. PROVIDE COMPLETE DETAIL/SPECS FOR ALT. W.L. &
 STUCCO SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH WIND
 RESISTANCE.
  
 6- PROVIDE ICC EVALUATION REPORT FOR THE ICYNENE R-20
 INSULATION TO VERIFY COMPLIANCE WITH SEC. R316
 FBC-RESIDENTIAL.
 NOTE: ENGINEER TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION IN NEW
 ADDITION. ALSO, SPECIFY SIZE FOR NEW ATTIC ACCESS SHOWN
 IN GARAGE AREA. SEC. R807 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-06 Cont ID  
Sent By fgiaquin Date 2022-06-06 Time 23:26 Rev Time 0.00
Received By fgiaquin Date 2022-06-06 Time 23:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-02-14 Cont ID  
Sent By fgiaquin Date 2022-02-14 Time 21:15 Rev Time 0.00
Received By fgiaquin Date 2022-02-14 Time 20:00 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2022-08-05 Cont ID  
Sent By amhamilt Date 2022-08-05 Time 15:39 Rev Time 0.00
Received By amhamilt Date 2022-08-05 Time 15:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-06-06 Cont ID  
Sent By amhamilt Date 2022-06-06 Time 15:53 Rev Time 0.00
Received By amhamilt Date 2022-06-06 Time 15:53 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By amhamilt Date 2022-02-24 Time 15:45 Rev Time 0.00
Received By amhamilt Date 2022-02-24 Time 15:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-15 Cont ID  
Sent By jgomez Date 2022-08-15 Time 17:16 Rev Time 0.00
Received By jgomez Date 2022-08-03 Time 13:50 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-08 Cont ID  
Sent By jgomez Date 2022-07-08 Time 17:21 Rev Time 0.00
Received By jgomez Date 2022-05-22 Time 13:01 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-23 Cont ID  
Sent By jgomez Date 2022-03-23 Time 15:51 Rev Time 0.00
Received By jgomez Date 2022-01-28 Time 08:57 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2022-09-14 Cont ID  
Sent By aoliver Date 2022-09-14 Time 12:31 Rev Time 0.00
Received By aoliver Date 2022-08-16 Time 08:01 Sent To  
Notes
2022-09-02 16:35:18RECEIPT MU-2022-039108 - $1945.04 PAID
2022-08-16 08:01:538/16/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-07-08 Cont ID  
Sent By jgomez Date 2022-07-08 Time 17:16 Rev Time 0.00
Received By jgomez Date 2022-07-08 Time 17:16 Sent To  
Notes
2022-07-08 17:17:06IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-03-23 Cont ID  
Sent By jgomez Date 2022-03-23 Time 15:48 Rev Time 0.00
Received By jgomez Date 2022-03-23 Time 15:47 Sent To  
Notes
2022-03-23 15:48:15IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 07:39 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 07:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-02-14 Cont ID  
Sent By medwards Date 2022-02-14 Time 13:22 Rev Time 0.00
Received By medwards Date 2022-02-14 Time 13:22 Sent To  
Notes
2022-02-14 13:23:201ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22011077
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ADDRESS GIVEN ON THE PERMIT, 803 KANUGA DR DOES
 NOT MATCH THE ADDRESS GIVEN ON THE MECHANICAL EQUIPMENT
 SIZING CALCULATIONS. PLEASE CORRECT THIS. FBC 107.2.1
  
 2) PLEASE ADD THE DUCT SIZES ON ALL OF THE DUCTWORK.
 FBC 107.2.1
  
 3) THERE APPEARS TO BE A 6X6 GRILL IN THE BATH AT THE
 PATIO AREA, PLEASE SHOW THE SUPPLY DUCT FOR THIS. FBC
 107.2.1
  
 4) PLEASE PROVIDE SPECIFICATIONS FOR THE HOOD FAN
 MOTOR. FBC RES M1503.4
  
 5) THE DRAWING MUST BE SIGNED BY THE DESIGNER.
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-01-30 Cont ID  
Sent By abelisle Date 2022-01-30 Time 12:49 Rev Time 0.00
Received By abelisle Date 2022-01-30 Time 10:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2022-08-15 Cont ID  
Sent By jgomez Date 2022-08-15 Time 17:13 Rev Time 0.00
Received By jgomez Date 2022-08-15 Time 17:12 Sent To  
Notes
2022-08-15 17:16:481- METAL ROOF ENGLERT SERIES 1300 NOA 21-1022.01
  
 2- ROOFING UNDERLAYMENT POLYGLASS POLYSTICK TU PLUS NOA
 21-0602.14

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-07-08 Cont ID  
Sent By jgomez Date 2022-07-08 Time 17:18 Rev Time 0.00
Received By jgomez Date 2022-07-08 Time 17:17 Sent To  
Notes
2022-07-08 17:17:49ROOFING REVIEW:
  
 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)METAL SHINGLES. PROVIDE COMPLETE AND CURRENT APPROVED
 PRODUCT APPROVAL. NEED COMPLETE FLORIDA PRODUCT
 APPROVAL, INCLUDING FLORIDA PRODUCT APPROVAL COVER PAGE
 SHOWING THE CURRENT CODE OR MIAMI DADE NOA.
 IF NONE OF THESE OPTIONS IS AVAILABLE, THEN
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL BY
 SUBMITTING COMPLETE ENGINEERING SIGNED AND SEALED
 DRAWINGS FOR BUILDING OFFICIAL APPROVAL. FAC
 61G20-3.001.
  
 RESPONSE:
 (1)TWO DIFFERENT PRODUCT APPROVALS WERE SUBMITTED.
 SUBMIT EITHER A COMPLETE MIAMI DADE NOA OR A COMPLETE
 FLORIDA PRODUCT APPROVAL INCLUDING THE COVER PAGE THAT
 CORRESPONDS TO THE INFORMATION SUBMITTED.
  
 (2) CLEARLY MARK ON PRODUCT APPROVAL WHICH METAL
 ROOFING FASTENING OPTION IS GOING TO BE USED. NEED THIS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES FOR ALL
 ROOF ZONES.
  
 ORIGINAL COMMENT:
 B)UNDERLAYMENT SPECIFIED ON PLANS FOR METAL SHINGLES.
  
 RESPONSE:
 PARTIALLY DONE. INFORMATION SUBMITTED IS MISSING
 FLORIDA PRODUCT APPROVAL COVER PAGE.
 NOTE: THE FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE
 IT SHOWS IF PRODUCT IS APPROVED AND CURRENT CODE IN
 EFFECT.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-03-23 Cont ID  
Sent By jgomez Date 2022-03-23 Time 15:48 Rev Time 0.00
Received By jgomez Date 2022-03-23 Time 15:48 Sent To  
Notes
2022-03-23 15:49:57ROOFING REVIEW:
  
 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL SHINGLES. PROVIDE COMPLETE AND CURRENT APPROVED
 PRODUCT APPROVAL. NEED COMPLETE FLORIDA PRODUCT
 APPROVAL, INCLUDING FLORIDA PRODUCT APPROVAL COVER PAGE
 SHOWING THE CURRENT CODE OR MIAMI DADE NOA.
 IF NONE OF THESE OPTIONS IS AVAILABLE, THEN
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL BY
 SUBMITTING COMPLETE ENGINEERING SIGNED AND SEALED
 DRAWINGS FOR BUILDING OFFICIAL APPROVAL. FAC
 61G20-3.001.
  
 B) UNDERLAYMENT SPECIFIED ON PLANS FOR METAL SHINGLES.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-08-03 Cont ID  
Sent By rmcdouga Date 2022-08-03 Time 17:19 Rev Time 0.00
Received By rmcdouga Date 2022-08-03 Time 17:19 Sent To  
Notes
2022-08-03 17:29:40SIGNED AND SEALED PLANS ON PAPER SENT TO STORAGE.
 SHEETS A-1, S-4, S-5, S-6, GD-1. RM

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By rmcdouga Date 2022-06-13 Time 14:50 Rev Time 0.00
Received By rmcdouga Date 2022-06-13 Time 14:50 Sent To  
Notes
2022-06-13 14:51:42ELECTRICAL AND MECHANICAL PLANS DO NOT HAVE AN ENGINEER
 OR ARCHITECT. SIGNED AND SEALED PLANS SENT TO STORAGE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-01-28 Cont ID  
Sent By ccole Date 2022-01-28 Time 11:24 Rev Time 0.00
Received By ccole Date 2022-01-28 Time 11:24 Sent To  
Notes
2022-01-28 11:30:58SIGNATURE REVIEW FBC- 2020
 PERMIT- 22011077
 1/28/22
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS SP-1, E-1, & AC-1 BEAR THE TITLE BLOCKS OF
 THE ARCHITECT AND ENGINEER OF RECORD BUT NOT THE SEAL
 AND WET SIGNATURES OF THE THOSE DESIGN PROFESSIONALS-
 SEE FL. STATUTES 471.025 & 481.221, AND SECTIONS
 61G15-23.002 & 61G1-16.0052 FLORIDA ADMINISTRATIVE
 CODE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-08-05 Cont ID  
Sent By amhamilt Date 2022-08-05 Time 15:39 Rev Time 0.00
Received By amhamilt Date 2022-08-05 Time 15:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-06-06 Cont ID  
Sent By amhamilt Date 2022-06-06 Time 15:53 Rev Time 0.00
Received By amhamilt Date 2022-06-06 Time 15:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By amhamilt Date 2022-02-24 Time 15:44 Rev Time 0.00
Received By amhamilt Date 2022-02-24 Time 15:44 Sent To  
Notes
***NONE***