Plan Review Stops For Permit 22010949 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-02-18 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-02-18 |
Time |
16:17 |
Sent To |
|
|
Notes |
2022-02-18 16:20:44 | ADDRESS APPROPRIATE FOR PROJECT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-24 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-22 |
Time |
16:46 |
Sent To |
|
|
Notes |
2022-06-23 12:02:35 | 6/23/22 PENDING PEER REVIEW OF CONSTRUCTION DRAWING | | ELEVATION CERTIFICATE. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-03 |
Time |
11:45 |
Sent To |
|
|
Notes |
2022-05-09 11:28:01 | PLAN REVIEW BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SUBMIT A CONSTRUCTION DRAWING ELEVATION CERTIFICATE. | | SEE NFIP REVIEW COMMENTS. | | | | 2. NOTE ON PLAN PAGE A-6.1 & A-6.2 STATES T.O. SLAB | | SHALL BE BFE + 1 FOOT. | | THE T.O. SLAB (DESIGN FLOOD ELEVATION) SHALL BE BFE + 2 | | FEET PER CITY ORDINANCE. | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | CODE, RESIDENTIAL. | | R322.2.1 ELEVATION REQUIREMENTS. | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | IS HIGHER. | | | | 3. PROVIDE THE FLORIDA PRODUCT APPROVALS AND ICC-ES | | REPORT FOR PROPOSED SMART VENTS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | NOTICE: A PRINT HOLD HAS BEEN APPLIED PENDING APPROVAL | | OF THE CONSTRUCTION DRAWING EC. | | A C/O HOLD HAS BEEN APPLIED PENDING APPROVAL OF THE | | FINISHED CONSTRCTION EC. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-06-23 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-06-23 |
Time |
12:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-03-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-03-13 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-03-13 |
Time |
09:41 |
Sent To |
|
|
Notes |
2022-03-13 12:10:10 | CODES IN EFFECT: | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) AC DISCONNECTS ON ROOF LACK WORKING CLEARANCES | | 110.26 | | | | 2) 1ST AND 2ND FLOORS HAVE A SYMBOL KP TO OUTLETS? | | | | 3) ELEVATOR, GENERATOR, POOL, LOW VOLTAGE SYSTEMS, TO | | HAVE SEPARATE PERMITS AND PLANS. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-07-12 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-07-12 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-07-05 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-07-05 |
Time |
|
Sent To |
|
|
Notes |
2022-07-05 08:36:38 | PASSED WITH PROVISO: UPDATE DEMO SHEET TO SHOW | | PROTECTION OF STORM INLET ALONG PROPERTY FRONTAGE. USE | | FILTER FABRIC OR OTHER BMP. | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB | | ENGINEERING SERVICES DEPARTMENT | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] HTTPS://WWW.WPB.ORG/GOVERNMENT/ | | ENGINEERING/ENGINEERING-STANDARDS-DETAILS | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-06-07 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-06-07 |
Time |
|
Sent To |
|
|
Notes |
2022-06-07 07:46:51 | PLEASE ADDRESS PREVIOUS ENGINEERING COMMENT. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-03-23 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-03-23 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-03-23 |
Time |
|
Sent To |
|
|
Notes |
2022-03-23 12:47:38 | A SWPPP WILL BE REQUIRED FOR DEMO/CLEARING. | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | STANDARDS-DETAILS | | CENTRAL OPERATIONS CENTER (DISPATCH): | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-01 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-01 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-02-24 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-02-24 |
Time |
07:15 |
Sent To |
|
|
Notes |
2022-02-24 11:12:34 | 02/24/22 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. WOULD YOU PLEASE LIST THE BTU LOAD OF EACH APPLIANCE | | AND THE TOTAL BTU LOAD OF THE SYSTEM? REFER TO THE 2020 | | FBC RES. SEC. G2413. | | | | 2. WOULD YOU PLEASE SUBMIT MANUFACTURER'S | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | APPROVED FOR OUTDOOR INSTALLATION PER THE 2020 FBC RES. | | SEC. G2421.1. | | | | 3. THERE IS A DETAIL ON P4.1 WOULD YOU PLEASE MOVE IT | | TO THIS PAGE GIVE A REFERENCE TO THAT DETAIL PER THE | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | | | 4. WOULD YOU PLEASE SHOW ON THE HOUSE PLAN THE LOCATION | | OF THE TANK-LESS WATER HEATER AND THE LOCATION AND | | DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN RELATION | | TO THE WATER HEATER? THE LOCATION OF THE WATER HEATER | | SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND-DRAWN PER THE | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | | | 5. WOULD YOU PLEASE SUBMIT CALCULATIONS FOR COMBUSTION | | AIR PER THE 2020 FBC RES. SEC. G2407.1 AND G2439.4 | | (CLOTHES DRYERS). IF THE LOUVER IS BEING USED, WOULD | | YOU PLEASE SHOW THE LOUVER(S) SIZE ON THE PLANS PER THE | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS? | | | | 6. WOULD YOU PLEASE SUBMIT THE MANUFACTURER'S | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH 2020 FBC RES. SEC. | | G2408.1. | | | | 7. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT | | SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020 | | FBC RES. SEC. G2413.2 AND G2404.3. | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON | | REQUEST. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-13 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-27 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-05-31 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-18 |
Time |
09:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-07-12 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-06-27 |
Time |
16:24 |
Sent To |
|
|
Notes |
2022-07-12 11:28:17 | RECEIPT MU-2022-029976 - $22.46 PAID | 2022-06-27 16:24:20 | 6/27/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-03 |
Time |
11:46 |
Sent To |
|
|
Notes |
2022-05-09 08:03:53 | IMPACT FEE QUESTIONNAIRE | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-01 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-01 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-03-03 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-03-03 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-03-03 |
Time |
16:55 |
Sent To |
|
|
Notes |
2022-03-03 16:55:21 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-22010949 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW THE DRYER DUCT, SIZE AND TERMINATION | | LOCATION. FBC RES M1502 | | | | 2) IS A KITCHEN HOOD GOING TO BE INSTALLED? IF SO | | PLEASE SPECIFY IF IT IS DUCTED TO THE OUTDOORS. IF SO, | | PLEASE SHOW THE EXHAUST FAN?S CFM?S. FBC RES M1503.4 | | | | 3) PLEASE SHOW THE CONDENSING UNITS LOCATION AND THE | | APPLIANCE TIE DOWN METHOD. FBC RES M1307.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-24 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-22 |
Time |
16:46 |
Sent To |
|
|
Notes |
2022-06-23 12:03:07 | 6/23/22 PENDING PEER REVIEW OF CONSTRUCTION DRAWING | | ELEVATION CERTIFICATE. CT | | 6/24/22 PEER REVIEW APPROVED. NFIP REVIEW PASSED. | | REMOVE PRINT HOLD. CT |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-03 |
Time |
11:55 |
Sent To |
|
|
Notes |
2022-05-09 11:20:01 | NFIP PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | IS AE WITH BASE FLOOD ELEVATIONS (BFE) OF 6'-0" & 7'-0" | | NAVD. | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | 9'-0" NAVD. | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | SHALL READ AS FOLLOWS: | | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | CODE, RESIDENTIAL. | | R322.2.1 ELEVATION REQUIREMENTS. | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | IS HIGHER. | | | | 2.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES | | IN THE FOLLOWING ORDER: | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | BUILDING. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-01 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-01 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2022-02-24 |
Time |
07:10 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2022-02-24 |
Time |
07:10 |
Sent To |
|
|
Notes |
2022-02-24 09:04:32 | 02/24/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. ON SHEETS P1.2 AND P3.1, THE # 7 RISER GOES TO A | | BATHROOM GROUP AND A KITCHEN. THE KITCHEN SINK CANNOT | | DISCHARGE INTO THE WET VET OF A BATHROOM GROUP. IT MUST | | BE DOWNSTREAM PER THE 2020 FBC SECTION R3108.1 | | HORIZONTAL WET VENT PERMITTED. | | | | 2. ON SHEETS P2.1 AND P2.2; | | | | A. THE HOT WATER LINES LOOPED FOR THE RECIRCULATING | | SYSTEM ARE NOT IN A CONTINUOUS LOOP. THERE IS A | | REQUIREMENT IN THE FLORIDA ENERGY CODE SEC. C404.6.1. | | THERE IS A TABLE THAT LIMITS THE BETWEEN THE SOURCE AND | | THE OUTLET; PLEASE REFER TO TABLE 404.5.1 FOR THE | | MAXIMUM ALLOWABLE PIPE LENGTH METHOD AND SIZE | | ACCORDANTLY. IF THERE ARE THREE SEPARATE AREAS OF THE | | TANK-LESS UNITS, EACH ONE SHALL HAVE ITS OWN RETURN; | | FEEL FREE TO CONTACT ME TO DISCUSS ACTION ON THE | | RECIRCULATING SYSTEM. | | | | B. WOULD YOU PLEASE PROVIDE A PLUMBING ISOMETRIC WATER | | RISER DIAGRAM PER THE WPB AMENDMENTS TO THE FBC SEC. | | 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | C. RECIRCULATING SYSTEM, THE PIPING SHALL BE INSULATED | | IN ITS ENTIRETY, INCLUDING THE SUPPLY AND RETURN PIPING | | OF A CIRCULATING PER C404.4 (A) INSULATION OF PIPING. | | | | D. GAS UNITS REQUIRE CONDENSATE, AND THEY NEED TO BE 1' | | AWAY FROM THE STRUCTURE PER THE 2020 FBC SEC R318.5. | | | | 3. ON SHEET P4.1; | | | | A. IT SHOWS THE SANITARY FOR THE STANDPIPE AS A | | COMBINATION FITTING THAT CHOCKS THE VENT. WOULD YOU | | PLEASE CORRECT PER THE 2020 FBC R 3005.1 DRAINAGE | | FITTINGS AND CONNECTIONS? | | | | B. IT SHOWS FOUR TANSLESS IN SERIES, BUT FIVE TOTAL MAY | | NEED THREE DIFFERENT SYSTEM CONFIGURATIONS PER COMMENT | | 2 - A. WOULD YOU PLEASE CORRECT PER THE WPB AMENDMENTS | | TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON | | REQUEST. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-03 |
Time |
11:45 |
Sent To |
|
|
Notes |
2022-05-09 08:09:19 | PROVISO ON PLAN PAGE S-6: A SEPERATE ROOFING PERMIT IS | | REQUIRED. | | NOTICE: YOU MAY SUBMIT ROOFING PRODUCT APPROVALS TO | | OBTAIN A ROOFING SUB-PERMIT UNTIL ALL REVIEWS ARE | | COMPLETE. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-13 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-13 |
Time |
15:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-06 |
Time |
09:35 |
Sent To |
|
|
Notes |
2022-07-06 09:36:42 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | 1) THE PROVIDED SURVEY DOES NOT SHOW AS DIGITALLY | | SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-23 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-22 |
Time |
16:46 |
Sent To |
|
|
Notes |
2022-06-01 14:16:44 | DIGITAL SIGNATURE HAS EXPIRED FOR THE STAND PRODUCT | | APPROVAL AND BMP CONDENSER TIE DOWN APPROVAL. ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-05-09 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-03 |
Time |
11:46 |
Sent To |
|
|
Notes |
2022-03-03 16:56:18 | DIGITAL SIGNATURE FOR MECHANICAL DRAWINGS NOT REQUIRED. | | ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-24 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-02-28 |
|
|
Cont ID |
|
Sent By |
afolke |
Date |
2022-02-28 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-02-28 |
Time |
16:52 |
Sent To |
|
|
Notes |
2022-02-28 16:57:05 | 02/28/22 FAILED - FAILED DUE TO UNSPECIFIED FINISHED | | GRADE ON BUILDING ELEVATION DRAWING FROM WHICH TO | | MEASURE BUILDING HEIGHT. | | | | ALEXANDER FOWLKES | | [email protected] | | 5618221431 |
|
|