Plan Review Details - Permit 22010949
Plan Review Stops For Permit 22010949
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-02-18 Cont ID  
Sent By cpuell Date 2022-02-18 Time 16:17 Rev Time 0.00
Received By cpuell Date 2022-02-18 Time 16:17 Sent To  
Notes
2022-02-18 16:20:44ADDRESS APPROPRIATE FOR PROJECT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By cthroop Date 2022-06-24 Time 10:40 Rev Time 0.00
Received By cthroop Date 2022-06-22 Time 16:46 Sent To  
Notes
2022-06-23 12:02:356/23/22 PENDING PEER REVIEW OF CONSTRUCTION DRAWING
 ELEVATION CERTIFICATE. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 11:20 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 11:45 Sent To  
Notes
2022-05-09 11:28:01PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SUBMIT A CONSTRUCTION DRAWING ELEVATION CERTIFICATE.
 SEE NFIP REVIEW COMMENTS.
  
 2. NOTE ON PLAN PAGE A-6.1 & A-6.2 STATES T.O. SLAB
 SHALL BE BFE + 1 FOOT.
 THE T.O. SLAB (DESIGN FLOOD ELEVATION) SHALL BE BFE + 2
 FEET PER CITY ORDINANCE.
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER.
  
 3. PROVIDE THE FLORIDA PRODUCT APPROVALS AND ICC-ES
 REPORT FOR PROPOSED SMART VENTS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NOTICE: A PRINT HOLD HAS BEEN APPLIED PENDING APPROVAL
 OF THE CONSTRUCTION DRAWING EC.
 A C/O HOLD HAS BEEN APPLIED PENDING APPROVAL OF THE
 FINISHED CONSTRCTION EC.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By jleahy Date 2022-06-23 Time 12:18 Rev Time 0.00
Received By jleahy Date 2022-06-23 Time 12:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-03-13 Cont ID  
Sent By jleahy Date 2022-03-13 Time 11:51 Rev Time 0.00
Received By jleahy Date 2022-03-13 Time 09:41 Sent To  
Notes
2022-03-13 12:10:10CODES IN EFFECT:
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) AC DISCONNECTS ON ROOF LACK WORKING CLEARANCES
 110.26
  
 2) 1ST AND 2ND FLOORS HAVE A SYMBOL KP TO OUTLETS?
  
 3) ELEVATOR, GENERATOR, POOL, LOW VOLTAGE SYSTEMS, TO
 HAVE SEPARATE PERMITS AND PLANS.

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2022-07-12 Cont ID  
Sent By rrossano Date 2022-07-12 Time   Rev Time 0.00
Received By rrossano Date 2022-07-12 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2022-07-05 Cont ID  
Sent By rrossano Date 2022-07-05 Time   Rev Time 0.00
Received By rrossano Date 2022-07-05 Time   Sent To  
Notes
2022-07-05 08:36:38PASSED WITH PROVISO: UPDATE DEMO SHEET TO SHOW
 PROTECTION OF STORM INLET ALONG PROPERTY FRONTAGE. USE
 FILTER FABRIC OR OTHER BMP.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB
 ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected] HTTPS://WWW.WPB.ORG/GOVERNMENT/
 ENGINEERING/ENGINEERING-STANDARDS-DETAILS
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-06-07 Cont ID  
Sent By rrossano Date 2022-06-07 Time   Rev Time 0.00
Received By rrossano Date 2022-06-07 Time   Sent To  
Notes
2022-06-07 07:46:51PLEASE ADDRESS PREVIOUS ENGINEERING COMMENT.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-03-23 Cont ID  
Sent By rrossano Date 2022-03-23 Time   Rev Time 0.00
Received By rrossano Date 2022-03-23 Time   Sent To  
Notes
2022-03-23 12:47:38A SWPPP WILL BE REQUIRED FOR DEMO/CLEARING.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-06-01 Cont ID  
Sent By rwbrown Date 2022-06-01 Time 14:42 Rev Time 0.00
Received By rwbrown Date 2022-06-01 Time 13:50 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-02-24 Cont ID  
Sent By lcrespo Date 2022-02-24 Time 07:15 Rev Time 0.00
Received By lcrespo Date 2022-02-24 Time 07:15 Sent To  
Notes
2022-02-24 11:12:3402/24/22 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE LIST THE BTU LOAD OF EACH APPLIANCE
 AND THE TOTAL BTU LOAD OF THE SYSTEM? REFER TO THE 2020
 FBC RES. SEC. G2413.
  
 2. WOULD YOU PLEASE SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION PER THE 2020 FBC RES.
 SEC. G2421.1.
  
 3. THERE IS A DETAIL ON P4.1 WOULD YOU PLEASE MOVE IT
 TO THIS PAGE GIVE A REFERENCE TO THAT DETAIL PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 4. WOULD YOU PLEASE SHOW ON THE HOUSE PLAN THE LOCATION
 OF THE TANK-LESS WATER HEATER AND THE LOCATION AND
 DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN RELATION
 TO THE WATER HEATER? THE LOCATION OF THE WATER HEATER
 SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND-DRAWN PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 5. WOULD YOU PLEASE SUBMIT CALCULATIONS FOR COMBUSTION
 AIR PER THE 2020 FBC RES. SEC. G2407.1 AND G2439.4
 (CLOTHES DRYERS). IF THE LOUVER IS BEING USED, WOULD
 YOU PLEASE SHOW THE LOUVER(S) SIZE ON THE PLANS PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS?
  
 6. WOULD YOU PLEASE SUBMIT THE MANUFACTURER'S
 SPECIFICATION SHEETS/INSTALLATION MANUAL FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH 2020 FBC RES. SEC.
 G2408.1.
  
 7. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020
 FBC RES. SEC. G2413.2 AND G2404.3.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-13 Cont ID  
Sent By jleahy Date 2022-07-13 Time 15:46 Rev Time 0.00
Received By jleahy Date 2022-07-08 Time 07:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 09:36 Rev Time 0.00
Received By rmcphers Date 2022-06-27 Time 16:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-24 Cont ID  
Sent By afowlkes Date 2022-06-24 Time 12:52 Rev Time 0.00
Received By afowlkes Date 2022-05-31 Time 16:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 11:28 Rev Time 0.00
Received By cthroop Date 2022-02-18 Time 09:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-07-12 Cont ID  
Sent By lmarchan Date 2022-07-12 Time 16:21 Rev Time 0.00
Received By lmarchan Date 2022-06-27 Time 16:24 Sent To  
Notes
2022-07-12 11:28:17RECEIPT MU-2022-029976 - $22.46 PAID
2022-06-27 16:24:206/27/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 08:01 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 11:46 Sent To  
Notes
2022-05-09 08:03:53IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-01 Cont ID  
Sent By medwards Date 2022-06-01 Time 14:15 Rev Time 0.00
Received By medwards Date 2022-06-01 Time 14:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-03 Cont ID  
Sent By medwards Date 2022-03-03 Time 16:55 Rev Time 0.00
Received By medwards Date 2022-03-03 Time 16:55 Sent To  
Notes
2022-03-03 16:55:211ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22010949
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE DRYER DUCT, SIZE AND TERMINATION
 LOCATION. FBC RES M1502
  
 2) IS A KITCHEN HOOD GOING TO BE INSTALLED? IF SO
 PLEASE SPECIFY IF IT IS DUCTED TO THE OUTDOORS. IF SO,
 PLEASE SHOW THE EXHAUST FAN?S CFM?S. FBC RES M1503.4
  
 3) PLEASE SHOW THE CONDENSING UNITS LOCATION AND THE
 APPLIANCE TIE DOWN METHOD. FBC RES M1307.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By cthroop Date 2022-06-24 Time 10:41 Rev Time 0.00
Received By cthroop Date 2022-06-22 Time 16:46 Sent To  
Notes
2022-06-23 12:03:076/23/22 PENDING PEER REVIEW OF CONSTRUCTION DRAWING
 ELEVATION CERTIFICATE. CT
 6/24/22 PEER REVIEW APPROVED. NFIP REVIEW PASSED.
 REMOVE PRINT HOLD. CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 11:15 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 11:55 Sent To  
Notes
2022-05-09 11:20:01NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE
 IS AE WITH BASE FLOOD ELEVATIONS (BFE) OF 6'-0" & 7'-0"
 NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'-0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
  
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER.
  
 2.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES
 IN THE FOLLOWING ORDER:
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-01 Cont ID  
Sent By rwbrown Date 2022-06-01 Time 14:42 Rev Time 0.00
Received By rwbrown Date 2022-06-01 Time 13:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-24 Cont ID  
Sent By lcrespo Date 2022-02-24 Time 07:10 Rev Time 0.00
Received By lcrespo Date 2022-02-24 Time 07:10 Sent To  
Notes
2022-02-24 09:04:3202/24/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEETS P1.2 AND P3.1, THE # 7 RISER GOES TO A
 BATHROOM GROUP AND A KITCHEN. THE KITCHEN SINK CANNOT
 DISCHARGE INTO THE WET VET OF A BATHROOM GROUP. IT MUST
 BE DOWNSTREAM PER THE 2020 FBC SECTION R3108.1
 HORIZONTAL WET VENT PERMITTED.
  
 2. ON SHEETS P2.1 AND P2.2;
  
 A. THE HOT WATER LINES LOOPED FOR THE RECIRCULATING
 SYSTEM ARE NOT IN A CONTINUOUS LOOP. THERE IS A
 REQUIREMENT IN THE FLORIDA ENERGY CODE SEC. C404.6.1.
 THERE IS A TABLE THAT LIMITS THE BETWEEN THE SOURCE AND
 THE OUTLET; PLEASE REFER TO TABLE 404.5.1 FOR THE
 MAXIMUM ALLOWABLE PIPE LENGTH METHOD AND SIZE
 ACCORDANTLY. IF THERE ARE THREE SEPARATE AREAS OF THE
 TANK-LESS UNITS, EACH ONE SHALL HAVE ITS OWN RETURN;
 FEEL FREE TO CONTACT ME TO DISCUSS ACTION ON THE
 RECIRCULATING SYSTEM.
  
 B. WOULD YOU PLEASE PROVIDE A PLUMBING ISOMETRIC WATER
 RISER DIAGRAM PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.3.5.3 (12) RESIDENTIAL PLUMBING.
  
 C. RECIRCULATING SYSTEM, THE PIPING SHALL BE INSULATED
 IN ITS ENTIRETY, INCLUDING THE SUPPLY AND RETURN PIPING
 OF A CIRCULATING PER C404.4 (A) INSULATION OF PIPING.
  
 D. GAS UNITS REQUIRE CONDENSATE, AND THEY NEED TO BE 1'
 AWAY FROM THE STRUCTURE PER THE 2020 FBC SEC R318.5.
  
 3. ON SHEET P4.1;
  
 A. IT SHOWS THE SANITARY FOR THE STANDPIPE AS A
 COMBINATION FITTING THAT CHOCKS THE VENT. WOULD YOU
 PLEASE CORRECT PER THE 2020 FBC R 3005.1 DRAINAGE
 FITTINGS AND CONNECTIONS?
  
 B. IT SHOWS FOUR TANSLESS IN SERIES, BUT FIVE TOTAL MAY
 NEED THREE DIFFERENT SYSTEM CONFIGURATIONS PER COMMENT
 2 - A. WOULD YOU PLEASE CORRECT PER THE WPB AMENDMENTS
 TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
  
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 08:07 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 11:45 Sent To  
Notes
2022-05-09 08:09:19PROVISO ON PLAN PAGE S-6: A SEPERATE ROOFING PERMIT IS
 REQUIRED.
 NOTICE: YOU MAY SUBMIT ROOFING PRODUCT APPROVALS TO
 OBTAIN A ROOFING SUB-PERMIT UNTIL ALL REVIEWS ARE
 COMPLETE. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-07-13 Cont ID  
Sent By jleahy Date 2022-07-13 Time 15:46 Rev Time 0.00
Received By jleahy Date 2022-07-13 Time 15:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 09:35 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 09:35 Sent To  
Notes
2022-07-06 09:36:42SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE PROVIDED SURVEY DOES NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By cthroop Date 2022-06-23 Time 09:37 Rev Time 0.00
Received By cthroop Date 2022-06-22 Time 16:46 Sent To  
Notes
2022-06-01 14:16:44DIGITAL SIGNATURE HAS EXPIRED FOR THE STAND PRODUCT
 APPROVAL AND BMP CONDENSER TIE DOWN APPROVAL. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-09 Cont ID  
Sent By cthroop Date 2022-05-09 Time 08:38 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 11:46 Sent To  
Notes
2022-03-03 16:56:18DIGITAL SIGNATURE FOR MECHANICAL DRAWINGS NOT REQUIRED.
 ME

Review Stop Z ZONING
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By afowlkes Date 2022-06-24 Time 12:51 Rev Time 0.00
Received By afowlkes Date 2022-06-24 Time 12:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-02-28 Cont ID  
Sent By afolke Date 2022-02-28 Time 16:57 Rev Time 0.00
Received By afowlkes Date 2022-02-28 Time 16:52 Sent To  
Notes
2022-02-28 16:57:0502/28/22 FAILED - FAILED DUE TO UNSPECIFIED FINISHED
 GRADE ON BUILDING ELEVATION DRAWING FROM WHICH TO
 MEASURE BUILDING HEIGHT.
  
 ALEXANDER FOWLKES
 [email protected]
 5618221431