Plan Review Details - Permit 22010940
Plan Review Stops For Permit 22010940 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-16 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-16 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-05-02 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-05-02 |
Time |
10:03 |
Sent To |
|
|
Notes |
2022-05-02 11:05:13 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | 3.) FBC B 107, THE PLAN AND APPLICATION REFER TO | | WINDOWS IN SEVERAL AREAS. NO PRODUCT APPROVAL FOR | | WINDOWS WAS SUBMITTED AND THERE IS NOTHING ON THE | | OPENING SCHEDULE FOR WINDOWS. IF WINDOWS ARE NOT | | PROPOSED, SUBMIT A NEW APPLICATION AND PLAN REMOVING | | WINDOWS FROM SCOPE OF WORK. | | | | 4.) FBC B 107, ALL PLAN SHEETS NEED TO BE SIGNED BY THE | | PERSON TAKING RESPONSIBILITY FOR THE PLAN SHEETS. IF | | THE PLAN SHEETS ARE FROM SIW WINDOWS & DOORS, AS TITLE | | BLOCK INDICATES, THEN THE PRINTED NAME & SIGNATURE | | (INCLUDING SEAL IF ARCHITECT OR ENGINEER IS SIGNING) | | MUST BE ON EACH PLAN SHEET. IF THERE IS NOT A TITLE | | BLOCK ON PLANS, THEN IT WILL BE CONSIDERED DESIGNED BY | | THE INDIVIDUAL THAT PRINTS NAME AND SIGNS NAME, SUCH AS | | A GENERAL CONTRACTOR. | | THE (3) PLAN SHEETS NEED TO BE NUMBERED AS A SET OF (3) | | AS FOLLOWS: | | | | PLAN SHEET (LAYOUT-SCHEDULE-ELEVATION) SHOULD BE | | LABELED 1 OF 3 NOT 1 OF 1. | | PLAN SHEET (DOOR LAYOUT) SHOULD BE LABELED 2 OF 3 NOT 1 | | OF 1. | | PLAN SHEET (DOOR LAYOUT/OCCUPANCY INFORMATION) SHOULD | | BE LABELED AS IS 3 OF 3. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-05 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-05 |
Time |
11:58 |
Sent To |
|
|
Notes |
2022-03-05 12:04:05 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. REVISE PLAN TO STATE OCCUPANCY CLASSIFICATION, FBC B | | CHAPTER 3. THE APPLICATION STATES THIS IS FOR | | "NORTHWOOD RESIDENCE". THIS IS A COMMERCIAL BUILDING. | | | | 2. SHOW THE ACCESSIBLE ROUTE. COASTAL DOOR HAS THE | | STANDARD THRESHOLD HIGHLIGHTED RATHER THAN THE ADA | | THRESHOLD. COMPLIANCE NOT CLEAR, FBC ACCESSIBLITY. SEE | | DEFINITION OF "ACCESSIBLE ROUTE" IN CHAPTER 2. | | | | 3. FBC 107, THE PLAN AND APPLICATION REFER TO WINDOWS, | | BUT NO WINDOWS SHOWN ON THE PLAN, NO PRODUCT APPROVAL | | SUBMITTED. IF WINDOWS ARE NOT PROPOSED, SUBMIT A NEW | | APPLICATION AND PLAN REMOVING WINDOWS FROM SCOPE. | | | | 4. INCLUDE THE PRINTED NAME AND SIGNATURE OF THE PERSON | | TAKING RESPONSIBILITY FOR THE PLAN, FBC 107. | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-04-13 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-04-13 |
Time |
09:22 |
Sent To |
|
|
Notes |
2022-04-13 09:42:29 | FIRE PROVISO COMMENTS: | | | | THERE ARE INDCIATIONS OF DOORS TO REMIAN UNLOCKED | | DURING OPERATION HOURS PER 7.2.1.5. | | | | HOWEVER, SHOULD THE NEED APPLY TO THESE DOORS OF OTHERS | | WITHIN THIS OCCUPANCY, | | | | PER NFPA 101 CH 38 NEW BUSINESS OCCUPANCY | | | | 38.2.2.2.2* DOOR LOCKING TO PREVENT UNWANTED ENTRY. | | WHERE | | APPROVED, DOORS, OTHER THAN THOSE COMPLYING WITH | | 38.2.11.2, SHALL BE | | PERMITTED TO BE LOCKED TO PREVENT UNWANTED ENTRY | | PROVIDED THAT ALL OF | | THE FOLLOWING CONDITIONS ARE MET: | | (1) THE LOCKING MEANS SHALL BE CAPABLE OF BEING ENGAGED | | WITHOUT | | OPENING THE DOOR. | | (2) THE UNLOCKING AND UNLATCHING OPERATION FROM THE | | EGRESS SIDE OF | | THE DOOR SHALL BE ACCOMPLISHED WITHOUT THE USE OF A | | KEY, TOOL, OR | | SPECIAL KNOWLEDGE OR EFFORT. | | (3) THE RELEASING MECHANISM SHALL OPEN THE DOOR LEAF | | WITH NOT MORE | | THAN ONE RELEASING OPERATION. | | (4) THE RELEASING MECHANISM FOR UNLOCKING AND | | UNLATCHING SHALL BE | | LOCATED AT A HEIGHT NOT LESS THAN 34 IN. (865 MM) AND | | NOT EXCEEDING | | 48 IN. (1220 MM) ABOVE THE FINISHED FLOOR. | | (5) LOCKS, IF REMOTELY ENGAGED, SHALL BE UNLOCKABLE | | FROM THE EGRESS | | SIDE OF THE DOOR WITHOUT THE USE OF A KEY, TOOL, OR | | SPECIAL KNOWLEDGE | | OR EFFORT. | | (6) THE DOOR SHALL BE CAPABLE OF BEING UNLOCKED AND | | OPENED FROM | | OUTSIDE THE ROOM WITH THE NECESSARY KEY OR OTHER | | CREDENTIAL. | | (7) THE LOCKING MEANS SHALL NOT MODIFY THE DOOR CLOSER, | | PANIC HARD WARE, OR FIRE EXIT HARDWARE. | | (8) MODIFICATIONS TO REQUIRED FIRE DOOR ASSEMBLIES, | | INCLUDING DOOR | | HARDWARE, SHALL BE IN ACCORDANCE WITH NFPA 80. | | | | A.38.2.2.2.2 THE INTENT OF THIS SECTION IS TO APPLY | | ONLY WHERE SPECIALIZED | | SECURITY MEASURES ARE NEEDED TO PREVENT UNWANTED ENTRY. | | EXAMPLES OF | | DOORS THAT MIGHT USE THESE PROVISIONS INCLUDE COLLEGE | | AND UNIVERSITY | | CLASSROOM DOORS, AREAS OF OFFICE SPACES OPEN TO THE | | PUBLIC, LABORATORIES, | | OR INSTRUCTIONAL ROOMS OR SPACES | | | | BE MINDFUL OF NFPA 101 CH 38 | | | | 38.2.2.2.3* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE | | PERMITTED ONLY ON | | PRINCIPAL ENTRANCE/EXIT DOORS. | | | | A.38.2.2.2.3 THE WORDS ?PRINCIPAL ENTRANCE/EXIT DOORS? | | DESCRIBE DOORS | | THAT THE AUTHORITY HAVING JURISDICTION CAN REASONABLY | | EXPECT TO BE | | UNLOCKED IN ORDER FOR THE FACILITY TO DO BUSINESS. | | | | PLEASE REVIEW AND ENSURE COMPLIANCE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-03-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-03-10 |
Time |
11:06 |
Sent To |
|
|
Notes |
2022-03-10 11:07:40 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) PLEASE PROVIDE THE OCCUPANCY CLASSIFICATION AND | | PROPSED OCCUPANCY LOAD OF THAT OCCUPANCY PER THE | | FLORIDA FIRE PREVENTION CODE. | | | | EXIT DOOR HARDWARE/REQUIREMENTS CAN BE DIFFERENT BASED | | ON THE OCCUPANCY/OCCUPANCY LOAD. | | | | | | 2) EXIT DOOR HARDWARE IS NOT PROVIDED THAT ENSURES | | COMPLIANCE WITH THE LIFE SAFETY CODE, NFPA 101 CH 7, | | MEANS OF EGRESS | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | READILY FROM THE | | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | OF A KEY, A TOOL, | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | EGRESS SIDE. | | | | 7.2.1.5.4 THE REQUIREMENTS OF 7.2.1.5.1 AND 7.2.1.5.3 | | SHALL NOT APPLY | | WHERE OTHERWISE PROVIDED IN CHAPTERS 18 THROUGH 23. | | | | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | LEAF SHALL BE | | PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS | | METHOD OF OPERATION | | AND THAT IS READILY OPERATED UNDER ALL LIGHTING | | CONDITIONS. | | | | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH | | SHALL BE LOCATED AS | | FOLLOWS: | | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED | | FLOOR FOR OTHER | | THAN EXISTING INSTALLATIONS | | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED | | FLOOR | | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE | | DOOR LEAF WITH NOT | | MORE THAN ONE RELEASING OPERATION, UNLESS OTHERWISE | | SPECIFIED IN | | 7.2.1.5.10.3, 7.2.1.5.10.4, 7.2.1.5.10.6, OR | | 7.2.1.5.10.7. | | | | PLEASE REVIEW AND PROVIDE DETAILS OF COMPLIANCE. | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-05-24 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-05-24 |
Time |
13:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-03-08 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-03-08 |
Time |
16:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-05-25 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-25 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-05-02 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-05-02 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-04-12 |
Time |
09:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-03-10 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-03-10 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-22 |
Time |
09:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-03-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-03-05 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-03-05 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|
|