Plan Review Details - Permit 22010874
Plan Review Stops For Permit 22010874
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-13 Cont ID  
Sent By cthroop Date 2022-07-13 Time 13:07 Rev Time 0.00
Received By cthroop Date 2022-07-13 Time 10:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-06-03 Cont ID  
Sent By jbaker Date 2022-06-03 Time 12:33 Rev Time 0.00
Received By jbaker Date 2022-06-03 Time 12:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-16 Cont ID  
Sent By cthroop Date 2022-04-16 Time 14:19 Rev Time 0.00
Received By cthroop Date 2022-04-15 Time 10:52 Sent To  
Notes
2022-04-16 14:59:45BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2015
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 2ND REQUEST:
  
 1. RE-SUBMIT PLAN PAGE A-101 AS A REVISION TO MASTER
 PERMIT 19080773.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE PRODUCT APPROVALS FL5822-R7 FOR SMART VENT
 MODELS 1540-574 (OHD) AND 1540-521 (STACKER VENT).
 INCLUDE THE COVER SHEET, EVALUATION REPORT AND
 INSTALLATION INSTRUCTIONS FOR EACH MODEL VENT.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NEW COMMENTS:
  
 3. SEPERATE THE ICC-ES REPORT FROM PRODUCT APPROVAL
 FL15822-R7 AND UPLOAD EACH DOCUMENT SEPERATELY.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 4. PRODUCT APPROVAL FL15822-R7 IS MISSING THE
 EVALUATION REPORT AND INSTALLATION INSTRUCTIONS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5. PROVIDE SQUARE FOOTAGE OF GARAGE AND TOTAL NET
 SQUARE INCHES OF SMART VENTS ON PLAN PAGE A-1.01.
 GARAGE IS 652 S/F.
 TOTAL SMART VENT NET OPENING IS 500 SQ/IN. COVERAGE
 EQUALS 800 S/F PER THE ICC-ES REPORT, TABLE 1.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-02-16 Cont ID  
Sent By cthroop Date 2022-02-16 Time 14:14 Rev Time 0.00
Received By cthroop Date 2022-02-11 Time 11:18 Sent To  
Notes
2022-02-16 14:27:01BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2015
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS
 SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0'
 NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE
 NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF
 FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT
 OR ABOVE 8.0' NAVD.
  
 NOTICE: PLAN PAGE A-1.01 SUBMITTED FOR REVIEW IS A COPY
 OF THE APPROVED, REVISED PLAN PAGE A-101, APPROVED
 UNDER MASTER PERMIT 19080773.
  
 1. RE-SUBMIT PLAN PAGE A-101 AS A REVISION TO MASTER
 PERMIT 19080773. PLACE FINISHED FLOOR ELEVATION OF
 GARAGE FLOOR ON PLAN.
 (FINISHED FLOOR OF MAIN DWELLING UNIT IS STATED AS 8.5'
 NAVD)
 (FINISHED FLOOR ELEVATION OF GARAGE IS STATED AS 6.0'
 NAVD) (SEE DRAINAGE PLAN C102)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE PRODUCT APPROVALS FL5822-R7 FOR SMART VENT
 MODELS 1540-574 (OHD) AND 1540-521 (STACKER VENT).
 INCLUDE THE COVER SHEET, EVALUATION REPORT AND
 INSTALLATION INSTRUCTIONS FOR EACH MODEL VENT.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-13 Cont ID  
Sent By cthroop Date 2022-07-13 Time 13:07 Rev Time 0.00
Received By cthroop Date 2022-06-09 Time 07:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-07 Cont ID  
Sent By cthroop Date 2022-06-07 Time 15:31 Rev Time 0.00
Received By cthroop Date 2022-05-09 Time 14:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-16 Cont ID  
Sent By cthroop Date 2022-04-16 Time 15:55 Rev Time 0.00
Received By cthroop Date 2022-03-02 Time 13:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-16 Cont ID  
Sent By cthroop Date 2022-02-16 Time 16:58 Rev Time 0.00
Received By cthroop Date 2022-01-24 Time 12:03 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 5 Status P Date 2022-07-18 Cont ID  
Sent By rmcdouga Date 2022-07-18 Time 17:18 Rev Time 0.00
Received By rmcdouga Date 2022-07-18 Time 16:56 Sent To  
Notes
2022-07-18 17:19:22FINAL SURVEY AND ELEVATION CERTIFICATE PEER REVIEW
 COMPLETED.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status F Date 2022-07-13 Cont ID  
Sent By cthroop Date 2022-07-13 Time 12:01 Rev Time 0.00
Received By cthroop Date 2022-07-13 Time 10:27 Sent To  
Notes
2022-07-13 12:02:55FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS PENDING
 AN INTERNAL PEER REVIEW. CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2022-06-07 Cont ID  
Sent By cthroop Date 2022-06-07 Time 15:27 Rev Time 0.00
Received By cthroop Date 2022-06-07 Time 05:50 Sent To  
Notes
2022-06-07 15:31:28NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
  
 3RD REVIEW
  
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) LINE A7 - BUILDING DIAGRAM IS INCORRECT.
 SEE LINE A7 ON BUILDING UNDER CONSTREUCTION EC AND PLAN
 PAGE A-3.01.
 BUILDING DIAGRAM SHOULD BE 1B.
 CORRECT AND RE-SUBMIT FINISHED CONSTRUCTION EC.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2022-04-16 Cont ID  
Sent By cthroop Date 2022-04-16 Time 15:31 Rev Time 0.00
Received By cthroop Date 2022-04-15 Time 10:52 Sent To  
Notes
2022-04-16 15:08:43NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
  
 2ND REVIEW
  
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NEW GENERAL COMMENTS:
  
 SEE FILE NAMED: PRODUCT APPROVAL-FLOOD VENT IN THE
 SUPPORTING DOCUMENTS FOR COMMENTS 1 & 2 BELOW:
  
 1. SEPERATE THE ICC-ES REPORT FROM PRODUCT APPROVAL
 FL15822-R7 AND UPLOAD EACH DOCUMENT SEPERATELY.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. PRODUCT APPROVAL FL15822-R7 IS MISSING THE
 EVALUATION REPORT AND INSTALLATION INSTRUCTIONS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NEW ELEVATION CERTIFICATE COMMENTS:
  
 3. LINE A6. PROVIDE A PHOTOGRAPH OF THE INSTALLED FLOOD
 VENT MODEL 1540-521 (STACKER).
  
 4. LINE A9. REQUIRED DATA IS THE TOTAL SQUARE INCHES OF
 THE FLOOD VENTS: THIS SHOULD BE 500 SQ/IN PER TABLE 1
 OF THE ICC-ES EVALUATION REPORT.
  
 5. LINE C2 (E). LOWEST ELEVATION OF EQUIPMENT SERVICING
 THE BUILDING IS THE AIR HANDLER LOCATED IN THE HVAC
 CLOSET INSIDE THE GARAGE.
 BOTTOM OF EQUIPMENT SHAL BE AT OR ABOVE THE DFE OF 8.0'
 NAVD.
 ENTER THIS INFORMATIUON IN THE COMMENTS AREA OF SECTION
 D.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2022-02-16 Cont ID  
Sent By cthroop Date 2022-02-16 Time 16:03 Rev Time 0.00
Received By cthroop Date 2022-02-11 Time 11:18 Sent To  
Notes
2022-02-16 16:58:12NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
  
 1ST REVIEW
  
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS
 SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0
 NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE
 NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF
 FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT
 OR ABOVE 8.0 NAVD.
  
 1. THE GARAGE DOOR VENT LETTER SUBMITTED FOR REVIEW BY
 SCPOTT HAMITON, P.E. REFERENCES NOA 20-0922.19 FOR THE
 OHD'S. THIS NOA CANNOT BE LOCATED UNDER MASTER PERMIT
 19080773. SUBMIT NOA 20-0922.19 FOR REVIEW.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. THE GARAGE FLOOD VENT LETTER SUBMITTED FOR REVIEW BY
 ROGER PATTERSON JANSSEN, P,E, IS TO RE-INSTALL THE
 FLOOD VENTS TO COMPLY WITH THE REQUIREMENTS OF FEMA'S
 NFIP TECHNICAL BULLETIN 1. SEE REVISED PLAN PAGE A-1.01
 SUBMITTED FOR REVIEW. 2 FLOOD VENTS, MODEL 1540-574,
 SHALL BE INSTALLED IN OHD #102 AND A STACKER VENT,
 MODEL 1540-521 WILL BE INSTALLED ON THE SOUTHWEST
 CORNER OF THE GARAGE.
 PROVIDE THE PRODUCT APPROVALS, FL5822-R7, FOR MODELS
 1540-574 AND 1540-521. INCLUDE THE COVER SHEET,
 EVALUATION REPORT AND INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE REFERENCE THE ELEVATION CERTIFICATE FOR THE
 FOLLWING COMMENTS:
  
 3. A6. PHOTOGRAPHS. THE CERTIFIER MUST PROVIDE AT LEAST
 2 PHOTOGRAPHS SHOWING THE FRONT AND REAR OF THE
 BUILDING TAKEN WITHIN 90 DAYS FROM THE DATE OF
 CERTIFICATION. PROVIDE A PHOTOGRAPH OF THE FOUNDATION
 SHOWING A REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS
 OR VENTS.
 FEMA EC INSTRUCTIONS PAGE 1 OF 9.
  
 4. A7. THE BUILDING DIAGRAM NUMBER IS STATED AS 1B.
 BASED ON THE FOUNDATION OF THE PROPOSED STRUCTURE, THE
 BUILDING DIAGRAM NUMBER SHOULD BE 1A.
 FEMA EC INSTRUCTIONS, PAGE 1 OF 9.
  
 5. A9 B). THE NUMBER OF FLOOD OPENINGS IS STATED AS 4.
 THERE ARE ONLY 3 FLOOD OPENINGS (1 ON THE SW CORNWER OF
 THE BUILDING AND 2 IN OHD #102.
 FEMA EC INSTRUCTIONS, PAGE 2 OF 9.
  
 6. SECTION D - COMMENTS. ITEM #3 REFERENCES FLOOD VENT
 MODEL: SMART VENT 1540-520. THIS MODEL IS NOT USED FOR
 THIS PROJECT, IT SHOULD STATE: MODELS 1540-521 AND
 1540-574.
 PROVIDE THE REFERENCED ICC-ES REPORT FOR THE SMART
 VENTS.
 PROVIDE THE TOP OF SLAB ELEVATION FOR THE FUTURE
 GENERATOR SHOWN ON SITE PLAN SP-1.01, UNDER MASTER
 PERMIT 19080773.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2022-07-18 Cont ID  
Sent By rmcdouga Date 2022-07-18 Time 17:45 Rev Time 0.00
Received By rmcdouga Date 2022-07-18 Time 17:45 Sent To  
Notes
2022-07-18 17:46:31DIGITAL SIGNATURE ON FINAL SURVEY WAS VERIFIED BY
 RICHARD GATHRIGHT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2022-07-13 Cont ID  
Sent By cthroop Date 2022-07-13 Time 13:04 Rev Time 0.00
Received By cthroop Date 2022-07-13 Time 10:27 Sent To  
Notes
2022-07-13 13:06:28SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2015
  
 5TH REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PLAN PAGES A-1.01, SURVEY AND FLOOD VENT AFFIDAVIT.
 NOTE: DIGITAL SIGNATURE ON EC IS APPROVED.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. UPLOAD DOCUMENTS WITH A VALID DIGITAL SIGNATURE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-06-06 Cont ID  
Sent By cthroop Date 2022-06-06 Time 15:17 Rev Time 0.00
Received By cthroop Date 2022-06-06 Time 15:00 Sent To  
Notes
2022-06-06 15:19:07SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2015
  
 4TH REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PLAN PAGES A-1.01, SURVEY AND FLOOD VENT AFFIDAVIT.
 NOTE: DIGITAL SIGNATURE ON EC IS APPROVED.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-04-16 Cont ID  
Sent By cthroop Date 2022-04-16 Time 14:59 Rev Time 0.00
Received By cthroop Date 2022-04-15 Time 11:01 Sent To  
Notes
2022-04-16 15:05:15SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2015
  
 3RD REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PLAN PAGES A-1.01, SURVEY, ELEVATION CERTIFICATE
 AND FLOOD VENT AFFIDAVIT.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-08 Cont ID  
Sent By rmcphers Date 2022-03-08 Time 08:33 Rev Time 0.00
Received By rmcphers Date 2022-03-08 Time 08:39 Sent To  
Notes
2022-03-08 08:33:14ORIGINAL SIGNED AND SEALED DRAWINGS (DATE ADDED TO
 PROJECTDOX 3-7-22) TO STORAGE
 1) ELEVATION CERTIFICATE FROM MICHAEL ZARRELLA SURVEYOR
 2) DRAWINGS A-1.01 FROM ROGER P. JANSSEN

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-01-24 Cont ID  
Sent By ccole Date 2022-01-24 Time 12:47 Rev Time 0.00
Received By ccole Date 2022-01-24 Time 12:47 Sent To  
Notes
2022-01-24 12:48:56SIGNATURE REVIEW
 PERMIT- 22010874
 1/24/2022
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ENGINEER?S LETTER CERTIFYING THE INSTALLATION OF
 THE VENTS IN THE GARAGE DOOR HAS A COPIED AND PRINTED
 DIGITAL SIGNATURE AND SEAL. PLANS AND DOCUMENTS
 PREPARED BY A FL. LICENSED ENGINEER THAT ARE
 TRANSMITTED ELECTRONIC MUST BEAR DIGITAL SIGNATURES AND
 SEALS THAT ARE CAPABLE OF BEING VERIFIED- FL. STATUTE
 471.025, AND SECTION 61G15-23.005 FAC.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-05-16 Cont ID  
Sent By vbroglia Date 2022-05-16 Time 15:17 Rev Time 0.00
Received By vbroglia Date 2022-05-16 Time 15:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-03-15 Cont ID  
Sent By vbroglia Date 2022-03-15 Time 14:52 Rev Time 0.00
Received By vbroglia Date 2022-03-15 Time 14:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-02-02 Cont ID  
Sent By vbroglia Date 2022-02-02 Time 11:53 Rev Time 0.00
Received By vbroglia Date 2022-02-02 Time 11:53 Sent To  
Notes
***NONE***