Plan Review Stops For Permit 22010874 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-07-13 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-07-13 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2022-06-03 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2022-06-03 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-04-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-04-16 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-04-15 |
Time |
10:52 |
Sent To |
|
|
Notes |
2022-04-16 14:59:45 | BUILDING PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2015 | | | | 2ND REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | 2ND REQUEST: | | | | 1. RE-SUBMIT PLAN PAGE A-101 AS A REVISION TO MASTER | | PERMIT 19080773. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE PRODUCT APPROVALS FL5822-R7 FOR SMART VENT | | MODELS 1540-574 (OHD) AND 1540-521 (STACKER VENT). | | INCLUDE THE COVER SHEET, EVALUATION REPORT AND | | INSTALLATION INSTRUCTIONS FOR EACH MODEL VENT. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | NEW COMMENTS: | | | | 3. SEPERATE THE ICC-ES REPORT FROM PRODUCT APPROVAL | | FL15822-R7 AND UPLOAD EACH DOCUMENT SEPERATELY. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 4. PRODUCT APPROVAL FL15822-R7 IS MISSING THE | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS. | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 5. PROVIDE SQUARE FOOTAGE OF GARAGE AND TOTAL NET | | SQUARE INCHES OF SMART VENTS ON PLAN PAGE A-1.01. | | GARAGE IS 652 S/F. | | TOTAL SMART VENT NET OPENING IS 500 SQ/IN. COVERAGE | | EQUALS 800 S/F PER THE ICC-ES REPORT, TABLE 1. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-16 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-11 |
Time |
11:18 |
Sent To |
|
|
Notes |
2022-02-16 14:27:01 | BUILDING PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2015 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS | | SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' | | NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE | | NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF | | FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT | | OR ABOVE 8.0' NAVD. | | | | NOTICE: PLAN PAGE A-1.01 SUBMITTED FOR REVIEW IS A COPY | | OF THE APPROVED, REVISED PLAN PAGE A-101, APPROVED | | UNDER MASTER PERMIT 19080773. | | | | 1. RE-SUBMIT PLAN PAGE A-101 AS A REVISION TO MASTER | | PERMIT 19080773. PLACE FINISHED FLOOR ELEVATION OF | | GARAGE FLOOR ON PLAN. | | (FINISHED FLOOR OF MAIN DWELLING UNIT IS STATED AS 8.5' | | NAVD) | | (FINISHED FLOOR ELEVATION OF GARAGE IS STATED AS 6.0' | | NAVD) (SEE DRAINAGE PLAN C102) | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE PRODUCT APPROVALS FL5822-R7 FOR SMART VENT | | MODELS 1540-574 (OHD) AND 1540-521 (STACKER VENT). | | INCLUDE THE COVER SHEET, EVALUATION REPORT AND | | INSTALLATION INSTRUCTIONS FOR EACH MODEL VENT. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-07-13 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-09 |
Time |
07:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-07 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-05-09 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-04-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-04-16 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-03-02 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-16 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-24 |
Time |
12:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
5 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-07-18 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-07-18 |
Time |
16:56 |
Sent To |
|
|
Notes |
2022-07-18 17:19:22 | FINAL SURVEY AND ELEVATION CERTIFICATE PEER REVIEW | | COMPLETED. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
4 |
Status |
F |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-07-13 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-07-13 |
Time |
10:27 |
Sent To |
|
|
Notes |
2022-07-13 12:02:55 | FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS PENDING | | AN INTERNAL PEER REVIEW. CT |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
3 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-07 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-07 |
Time |
05:50 |
Sent To |
|
|
Notes |
2022-06-07 15:31:28 | NFIP PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | 3RD REVIEW | | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) LINE A7 - BUILDING DIAGRAM IS INCORRECT. | | SEE LINE A7 ON BUILDING UNDER CONSTREUCTION EC AND PLAN | | PAGE A-3.01. | | BUILDING DIAGRAM SHOULD BE 1B. | | CORRECT AND RE-SUBMIT FINISHED CONSTRUCTION EC. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
F |
Date |
2022-04-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-04-16 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-04-15 |
Time |
10:52 |
Sent To |
|
|
Notes |
2022-04-16 15:08:43 | NFIP PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | 2ND REVIEW | | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NEW GENERAL COMMENTS: | | | | SEE FILE NAMED: PRODUCT APPROVAL-FLOOD VENT IN THE | | SUPPORTING DOCUMENTS FOR COMMENTS 1 & 2 BELOW: | | | | 1. SEPERATE THE ICC-ES REPORT FROM PRODUCT APPROVAL | | FL15822-R7 AND UPLOAD EACH DOCUMENT SEPERATELY. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 2. PRODUCT APPROVAL FL15822-R7 IS MISSING THE | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS. | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | NEW ELEVATION CERTIFICATE COMMENTS: | | | | 3. LINE A6. PROVIDE A PHOTOGRAPH OF THE INSTALLED FLOOD | | VENT MODEL 1540-521 (STACKER). | | | | 4. LINE A9. REQUIRED DATA IS THE TOTAL SQUARE INCHES OF | | THE FLOOD VENTS: THIS SHOULD BE 500 SQ/IN PER TABLE 1 | | OF THE ICC-ES EVALUATION REPORT. | | | | 5. LINE C2 (E). LOWEST ELEVATION OF EQUIPMENT SERVICING | | THE BUILDING IS THE AIR HANDLER LOCATED IN THE HVAC | | CLOSET INSIDE THE GARAGE. | | BOTTOM OF EQUIPMENT SHAL BE AT OR ABOVE THE DFE OF 8.0' | | NAVD. | | ENTER THIS INFORMATIUON IN THE COMMENTS AREA OF SECTION | | D. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-16 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-11 |
Time |
11:18 |
Sent To |
|
|
Notes |
2022-02-16 16:58:12 | NFIP PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | 1ST REVIEW | | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD | | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS | | SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0 | | NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE | | NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF | | FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT | | OR ABOVE 8.0 NAVD. | | | | 1. THE GARAGE DOOR VENT LETTER SUBMITTED FOR REVIEW BY | | SCPOTT HAMITON, P.E. REFERENCES NOA 20-0922.19 FOR THE | | OHD'S. THIS NOA CANNOT BE LOCATED UNDER MASTER PERMIT | | 19080773. SUBMIT NOA 20-0922.19 FOR REVIEW. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 2. THE GARAGE FLOOD VENT LETTER SUBMITTED FOR REVIEW BY | | ROGER PATTERSON JANSSEN, P,E, IS TO RE-INSTALL THE | | FLOOD VENTS TO COMPLY WITH THE REQUIREMENTS OF FEMA'S | | NFIP TECHNICAL BULLETIN 1. SEE REVISED PLAN PAGE A-1.01 | | SUBMITTED FOR REVIEW. 2 FLOOD VENTS, MODEL 1540-574, | | SHALL BE INSTALLED IN OHD #102 AND A STACKER VENT, | | MODEL 1540-521 WILL BE INSTALLED ON THE SOUTHWEST | | CORNER OF THE GARAGE. | | PROVIDE THE PRODUCT APPROVALS, FL5822-R7, FOR MODELS | | 1540-574 AND 1540-521. INCLUDE THE COVER SHEET, | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE REFERENCE THE ELEVATION CERTIFICATE FOR THE | | FOLLWING COMMENTS: | | | | 3. A6. PHOTOGRAPHS. THE CERTIFIER MUST PROVIDE AT LEAST | | 2 PHOTOGRAPHS SHOWING THE FRONT AND REAR OF THE | | BUILDING TAKEN WITHIN 90 DAYS FROM THE DATE OF | | CERTIFICATION. PROVIDE A PHOTOGRAPH OF THE FOUNDATION | | SHOWING A REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS | | OR VENTS. | | FEMA EC INSTRUCTIONS PAGE 1 OF 9. | | | | 4. A7. THE BUILDING DIAGRAM NUMBER IS STATED AS 1B. | | BASED ON THE FOUNDATION OF THE PROPOSED STRUCTURE, THE | | BUILDING DIAGRAM NUMBER SHOULD BE 1A. | | FEMA EC INSTRUCTIONS, PAGE 1 OF 9. | | | | 5. A9 B). THE NUMBER OF FLOOD OPENINGS IS STATED AS 4. | | THERE ARE ONLY 3 FLOOD OPENINGS (1 ON THE SW CORNWER OF | | THE BUILDING AND 2 IN OHD #102. | | FEMA EC INSTRUCTIONS, PAGE 2 OF 9. | | | | 6. SECTION D - COMMENTS. ITEM #3 REFERENCES FLOOD VENT | | MODEL: SMART VENT 1540-520. THIS MODEL IS NOT USED FOR | | THIS PROJECT, IT SHOULD STATE: MODELS 1540-521 AND | | 1540-574. | | PROVIDE THE REFERENCED ICC-ES REPORT FOR THE SMART | | VENTS. | | PROVIDE THE TOP OF SLAB ELEVATION FOR THE FUTURE | | GENERATOR SHOWN ON SITE PLAN SP-1.01, UNDER MASTER | | PERMIT 19080773. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-07-18 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-07-18 |
Time |
17:45 |
Sent To |
|
|
Notes |
2022-07-18 17:46:31 | DIGITAL SIGNATURE ON FINAL SURVEY WAS VERIFIED BY | | RICHARD GATHRIGHT. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-07-13 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-07-13 |
Time |
10:27 |
Sent To |
|
|
Notes |
2022-07-13 13:06:28 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2015 | | | | 5TH REVIEW | | RESULTS: DENIED | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PLAN PAGES A-1.01, SURVEY AND FLOOD VENT AFFIDAVIT. | | NOTE: DIGITAL SIGNATURE ON EC IS APPROVED. | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. UPLOAD DOCUMENTS WITH A VALID DIGITAL SIGNATURE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-06-06 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-06-06 |
Time |
15:00 |
Sent To |
|
|
Notes |
2022-06-06 15:19:07 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2015 | | | | 4TH REVIEW | | RESULTS: DENIED | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PLAN PAGES A-1.01, SURVEY AND FLOOD VENT AFFIDAVIT. | | NOTE: DIGITAL SIGNATURE ON EC IS APPROVED. | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-04-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-04-16 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-04-15 |
Time |
11:01 |
Sent To |
|
|
Notes |
2022-04-16 15:05:15 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2015 | | | | 3RD REVIEW | | RESULTS: DENIED | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: PLAN PAGES A-1.01, SURVEY, ELEVATION CERTIFICATE | | AND FLOOD VENT AFFIDAVIT. | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-08 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-08 |
Time |
08:39 |
Sent To |
|
|
Notes |
2022-03-08 08:33:14 | ORIGINAL SIGNED AND SEALED DRAWINGS (DATE ADDED TO | | PROJECTDOX 3-7-22) TO STORAGE | | 1) ELEVATION CERTIFICATE FROM MICHAEL ZARRELLA SURVEYOR | | 2) DRAWINGS A-1.01 FROM ROGER P. JANSSEN |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-01-24 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-01-24 |
Time |
12:47 |
Sent To |
|
|
Notes |
2022-01-24 12:48:56 | SIGNATURE REVIEW | | PERMIT- 22010874 | | 1/24/2022 | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE ENGINEER?S LETTER CERTIFYING THE INSTALLATION OF | | THE VENTS IN THE GARAGE DOOR HAS A COPIED AND PRINTED | | DIGITAL SIGNATURE AND SEAL. PLANS AND DOCUMENTS | | PREPARED BY A FL. LICENSED ENGINEER THAT ARE | | TRANSMITTED ELECTRONIC MUST BEAR DIGITAL SIGNATURES AND | | SEALS THAT ARE CAPABLE OF BEING VERIFIED- FL. STATUTE | | 471.025, AND SECTION 61G15-23.005 FAC. | | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | DOCUMENTS. | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | USE A THIRD PARTY. | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | AND DOCUMENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-05-16 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-05-16 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-03-15 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-03-15 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-02-02 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-02-02 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|