Plan Review Details - Permit 22010581
Plan Review Stops For Permit 22010581
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-08-09 Cont ID  
Sent By cpuell Date 2022-08-09 Time 11:25 Rev Time 0.00
Received By cpuell Date 2022-08-09 Time 11:25 Sent To  
Notes
2022-08-09 11:27:16NEW EAST 2 STORY BLDG WITH GARAGE DOWNSTAIRS AND
 APARTMENT UPSTAIRS GIVEN THE ADDRESS OF 427 25TH ST,
 REMODEL TO WEST BUILDING APARTMENT GIVEN THE NEW
 ADDRESS OF 431 25TH ST, NO WORK ON 429 25TH ST, UPDATED
 PERMIT

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-07-12 Cont ID  
Sent By cpuell Date 2022-07-12 Time 15:01 Rev Time 0.00
Received By cpuell Date 2022-07-12 Time 15:01 Sent To  
Notes
2022-07-12 15:01:21PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-07-08 Cont ID  
Sent By cpuell Date 2022-07-08 Time 15:56 Rev Time 0.00
Received By cpuell Date 2022-07-08 Time 15:56 Sent To  
Notes
2022-07-08 16:05:32CURRENTLY TWO ADDRESSES ON THIS PARCEL, 427 25TH ST FOR
 THE 2ND FLOOR AND 429 25TH ST FOR THE 1ST FLOOR. SECOND
 FLOOR PROPOSED PLANS, REFERENCED A UNIT A AND A UNIT B,
 THESE ARE NOT APPROVED ADDRESSES. PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 TO DISCUSS
 ADDRESSING ISSUES.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-01-15 Cont ID  
Sent By shill Date 2022-01-15 Time 13:40 Rev Time 0.00
Received By shill Date 2022-01-15 Time 13:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-17 Cont ID  
Sent By rmcphers Date 2022-10-17 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2022-10-17 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-01 Cont ID  
Sent By rmcphers Date 2022-08-01 Time 11:43 Rev Time 0.00
Received By rmcphers Date 2022-08-01 Time 11:43 Sent To  
Notes
2022-08-01 11:46:27BUILDING ADDITION AND ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE LOCATION OF THE REQUIRED CARBON
 MONOXIDE DETECTOR - FBC 915.1 CARBON MONOXIDE
 PROTECTION.
 EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING
 BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS
 ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR
 APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER
 FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE
 AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL
 CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET (3050
 MM) OF EACH ROOM USED FOR SLEEPING PURPOSES IN THE NEW
 BUILDING OR ADDITION, OR AT SUCH OTHER LOCATIONS AS
 REQUIRED BY THIS CODE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-11 Cont ID  
Sent By mpeterso Date 2022-10-11 Time 14:21 Rev Time 0.00
Received By mpeterso Date 2022-10-11 Time 14:21 Sent To  
Notes
2022-10-11 14:21:42AUDIT OF ELECTRICAL PLANS PASSED

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-08-01 Cont ID  
Sent By mpeterso Date 2022-08-01 Time 09:57 Rev Time 0.00
Received By mpeterso Date 2022-08-01 Time 11:40 Sent To  
Notes
2022-08-01 11:32:32ELECTRIC REVIEW AUDIT FAILED
 1) NEW PANELS AND ELECTRIC LOADS ARE DETAILED. PLEASE
 PROVIDE ACCURATE RISER DIAGRAM FOR ENTIRE SERVICE
 INCLUDING BOTH APARTMENTS AND GALLERY, INCLUDE
 CONDUCTOR AND OVERCURRENT SIZES. NEC 215.5
 2) PLEASE DETAIL COMPLIANCE WITH FBC R 315 REGARDING
 CARBON MONOXIDE ALARMS
 3) PLEASE DETAIL WHAT DISCONNECT SHOWN ON FIRST FLOOR
 ELECTRIC PLAN IS USED FOR. FBC 107.2
 4) PLEASE REMOVE NOTE ON 2ND FLOOR ELECTRIC PLAN
 STATING ONLY WORK THIS APARTMENT = EXTEND TRACK. FBC
 107.2
 5) DETAIL ALL ELECTRIC WORK TO BE REMOVED IN DEMOLISHED
 WALLS. PLEASE INCLUDE ELECTRIC PANELS, RECEPTACLES,
 SWITCHES, AIR CONDITIONING EQUIPMENT AND ANY OTHER
 APPLICABLE ELECTRIC WIRING
 6) PLEASE SHOW COMPLIANCE FOR NEW ELECTRIC PANEL 427B
 FOR NEC 110.26 CLEARANCES.
 7) ELECTRIC PANEL 427A APPEARS TO BE LOCATED IN A
 CLOSET WHICH IS NOT IN COMPLIANCE WITH NEC 240.24 (D)
 8) PLEASE PROVIDE ALL DETAILS AND SPECIFICATIONS FOR
 NEW ELEVATOR, FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2022-09-27 Cont ID  
Sent By pleduc Date 2022-09-27 Time   Rev Time 0.00
Received By pleduc Date 2022-09-26 Time 12:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-07-14 Cont ID  
Sent By pleduc Date 2022-07-14 Time   Rev Time 0.00
Received By pleduc Date 2022-07-14 Time 14:39 Sent To  
Notes
2022-07-14 14:42:33FIRE PROVISO:
  
 THE FIRE SPRINKLER DOCUMENTS STILL NEED TO BE SUBMITTED
 AS A PART OF THIS MASTER PERMIT AS REQUIRED PER F.A.C.
 69G.
  
 FOR THE OFFICIAL RECORD, PLEASE SUBMIT THE REQUIRED
 FIRE SPRINKLER DOCUMENTS AS A DEFERRED SUBMITTAL TO
 THIS MASTER AS SOON AS POSSIBLE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-05-16 Cont ID  
Sent By pleduc Date 2022-05-16 Time   Rev Time 0.00
Received By pleduc Date 2022-05-16 Time 14:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2022-03-25 Cont ID  
Sent By pleduc Date 2022-03-25 Time   Rev Time 0.00
Received By pleduc Date 2022-03-25 Time 10:34 Sent To  
Notes
2022-03-25 10:55:05THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO INDICATION NOR DOCUMENTS SUBMITTED FOR
 THE FIRE SPRINKLER PROTECTION REQUIREMENTS PER F.A.C.
 69 A.
  
 PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004,
 FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF
 APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING
 DOCUMENTS.
 (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF
 PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR
 INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING
 PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER?S
 RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31,
 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE AHJ. THE DOCUMENTS SHALL INCLUDE:
  
 THOUGH A SEPARATE PERMIT FOR THE FIRE SPRINKLER SYSTEM
 HAS BEEN SUBMITTED, THOSE DOCUMENTS ARE REQUIRED TO BE
 ATTACHED TO THIS MASTER.
  
  
  
 2) THERE ARE INDICATIONS ON THE LIFE SAFETY SHEETS THAT
 A MANUAL FIRE ALARM IS NOT REQUIRED; HOWEVER, WHERE A
 FIRE SPRINKLER SYSTEM HAS BEEN INSTALLED IT SHALL BE
 MONITORED.
  
 PER NFPA 101, CH 9
 9.7.2.1.1 WHERE SUPERVISED AUTOMATIC SPRINKLER SYSTEMS
 ARE REQUIRED
 BY ANOTHER SECTION OF THIS CODE, SUPERVISORY
 ATTACHMENTS SHALL BE
 INSTALLED AND MONITORED FOR INTEGRITY IN ACCORDANCE
 WITH NFPA 72 AND
 A DISTINCTIVE SUPERVISORY SIGNAL SHALL BE PROVIDED TO
 INDICATE A CONDITION
 THAT WOULD IMPAIR THE SATISFACTORY OPERATION OF THE
 SPRINKLER SYSTEM.
 9.7.2.1.2 SUPERVISORY SIGNALS SHALL SOUND AND SHALL BE
 DISPLAYED EITHER AT
 A LOCATION WITHIN THE PROTECTED BUILDING THAT IS
 CONSTANTLY ATTENDED BY QUALI FIED PERSONNEL OR AT AN
 APPROVED, REMOTELY LOCATED RECEIVING FACILITY.
 9.7.2.2 ALARM SIGNAL TRANSMISSION.
 9.7.2.2.1 WHERE SUPERVISION OF AUTOMATIC SPRINKLER
 SYSTEMS IS REQUIRED
 BY ANOTHER SECTION OF THIS CODE, WATERFLOW ALARMS SHALL
 BE TRANSMITTED
 TO AN APPROVED, PROPRIETARY ALARM-RECEIVING FACILITY, A
 REMOTE STATION, A
 CENTRAL STATION, OR THE FIRE DEPARTMENT
 9.7.2.2.2 THE CONNECTION DESCRIBED IN 9.7.2.2.1 SHALL
 BE IN ACCORDANCE
 WITH 9.6.1.3.
  
 9.6.1.3 FIRE ALARM SYSTEMS REQUIRED BY THIS CODE SHALL
 BE INSTALLED,
 TESTED, AND MAINTAINED IN ACCORDANCE WITH THE
 APPLICABLE REQUIREMENTS
 OF NFPA 70 AND NFPA 72 UNLESS IT IS AN APPROVED
 EXISTING INSTALLATION,
 WHICH SHALL BE PERMITTED TO BE CONTINUED IN USE.
  
 PLEASE REVIEW AND PROVIDE A CLOUDED NOTE OF
 ACKNOWLEDGMENT ON THESE PAGES.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-01-28 Cont ID  
Sent By pleduc Date 2022-01-28 Time   Rev Time 0.00
Received By pleduc Date 2022-01-28 Time 11:53 Sent To  
Notes
2022-01-28 12:46:05THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A FIRE SPRINKLER
 PROTECTION; HOWEVER, THERE IS NO INDICATION OF FIRE
 SPRINKLER DOCUMENTATION REQUIRED BY F.A.C 61G
  
 FAC 61G15-32.002 DEFINES THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENT (5) AS WELL AS THE FIRE PROTECTION
 SYSTEM LAYOUT DOCUMENT (6). 61G15-32.003
 OUTLINES THE COMMON REQUIREMENTS TO ALL FIRE
 PROTECTIONS ENGINEERING DOCUMENTS WITH 32.004 (2) (A-J)
 OUTLINING THE MINIMUM INFORMATION TO BE PROVIDED ON
 FIRE
 PROTECTION ENGINEERING DOCUMENTS FOR WATER BASED
 SYSTEMS. AS STATED IN THE DEFINITIONS, THE CONTRACTOR
 IS TO DEVELOP THE LAYOUT DOCUMENTS BASED ON THE DESIGN
 CRITERIA PROVIDED IN THE FIRE PROTECTION ENGINEERING
 DOCUMENTS BY THE ENGINEER OF RECORD FOR THE FIRE
 SPRINKLER SYSTEM. THE FIRE PROTECTION SYSTEM
 ENGINEERING
 DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING
 PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED
 FOR THE FIRE SPRINKLER INSTALLATION PERMIT.
  
 EVEN IF THE EOR DEFERS TO A LOCAL QUALIFIED CONTRACTOR,
 THAT CONTRACTOR MUST SUBMIT THE REQUIRED 61G
 INFORMATION WITH THIS MASTER.
  
 PLEASE REVIEW AND SUBMIT THE REQUIRED INFORMATION.
  
  
 2) THERE IS NO INDICATION OF THE REQUIRED FIRE RATING
 SEPARATION OF THE 1ST/2ND FLOOR.
  
 PER NFPA 101 CH 6 A 2 HOUR SEPARATION IS REQUIRED
 BETWEEN RESIDENTIAL & MERCANTILE AND STORAGE.
  
 PLEASE PROVIDE THE DETAILS OF THE REQUIRED SEPARATION.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2022-10-17 Cont ID  
Sent By rmcphers Date 2022-10-17 Time 09:27 Rev Time 0.00
Received By rmcphers Date 2022-09-23 Time 09:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-08-01 Cont ID  
Sent By rmcphers Date 2022-08-01 Time 11:48 Rev Time 0.00
Received By rmcphers Date 2022-07-14 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2022-07-14 Time   Rev Time 0.00
Received By aoliver Date 2022-07-12 Time 08:37 Sent To  
Notes
2022-07-13 07:33:36NEW FLOOR PLANS, NEEDS FIRE BEFORE AUDIT

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-07-07 Time   Rev Time 0.00
Received By aoliver Date 2022-06-30 Time 07:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-01 Cont ID  
Sent By shill Date 2022-06-01 Time 09:08 Rev Time 0.00
Received By shill Date 2022-05-16 Time 14:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-04-27 Time   Rev Time 0.00
Received By lmarchan Date 2022-03-24 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-24 Cont ID  
Sent By aoliver Date 2022-02-24 Time 10:50 Rev Time 0.00
Received By aoliver Date 2022-01-24 Time 10:36 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-10-27 Cont ID  
Sent By lmarchan Date 2022-10-27 Time 10:08 Rev Time 0.00
Received By lmarchan Date 2022-10-11 Time 12:59 Sent To  
Notes
2022-10-26 16:13:15RECEIPT MU-2022-048249 - $8135.91 PAID
2022-10-11 12:59:3110/11/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-01 Cont ID  
Sent By rmcphers Date 2022-08-01 Time 11:46 Rev Time 0.00
Received By rmcphers Date 2022-08-01 Time 11:46 Sent To  
Notes
2022-08-01 11:47:29PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-10-17 Cont ID  
Sent By medwards Date 2022-10-17 Time 06:00 Rev Time 0.00
Received By medwards Date 2022-10-17 Time 06:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-29 Cont ID  
Sent By medwards Date 2022-07-29 Time 13:24 Rev Time 0.00
Received By medwards Date 2022-07-29 Time 13:24 Sent To  
Notes
2022-07-29 13:29:19THIS IS A COMMERCIAL PROJECT. THE DESIGNER OF THE
 MECHANICAL SYSTEM MUST HOLD THE MECHANICAL PERMIT TO
 INSTALL THE MECHANICAL SYSTEM OR THE DESIGN MUST BE
 DESIGNED BY A LICENSED ENGINEER. FS 489
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-10-11 Cont ID  
Sent By rwbrown Date 2022-10-11 Time 14:36 Rev Time 0.00
Received By rwbrown Date 2022-10-11 Time 14:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-07-29 Cont ID  
Sent By rwbrown Date 2022-07-29 Time 11:13 Rev Time 0.00
Received By rwbrown Date 2022-07-29 Time 10:40 Sent To  
Notes
2022-07-29 11:13:461ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - PAGE P3 - THE ISOMETRIC
 LABELS THE SHOWER DRAIN AS WM. PLEASE CORRECT.
  
 2. 2017 WPB AMENDS 107.2.1 - PAGE P3 - THE FLOOR PLAN
 ON P2 SHOWS A VENT FOR THE WATER CLOSET AND THE
 ISOMETRIC DOES NOT. PLEASE CORRECT.
  
 3. 2017 WPB AMENDS 107.2.1 - PAGE P3 - ON THE ISOMETRIC
 YOU'VE LABELED THE FIXTURE DRAIN FOR THE WATER CLOSET
 AS 2" AND 3" IS REQUIRED.
  
 4. 2017 WPB AMENDS 107.2.1 - PAGE P3 - THE ISOMETRIC
 APPEARS TO BE MISSING THE WATER LINE FOR THE WATER
 CLOSET IN BATH 3.
  
 5. 2020 FRC P2905.3 - ACCORDING TO THE SCALE ON YOUR
 WATER RISER, IT IS OVER 100 FEET FROM THE TANKLESS TO
 THE FARTHEST FIXTURE. IF THIS IS THE CASE, YOU WILL
 NEED A RECIRCULATING LINE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status P Date 2022-10-11 Cont ID  
Sent By jleahy Date 2022-10-11 Time 14:38 Rev Time 0.00
Received By jleahy Date 2022-10-11 Time 14:38 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2022-07-19 Time   Rev Time 0.00
Received By   Date 2022-07-19 Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2022-07-07 Time   Rev Time 0.00
Received By   Date 2022-07-07 Time   Sent To  
Notes
2022-07-07 07:13:59FS553.791, AN ACCURATE CURRENT AFFIDAVIT IS REQUIRED
 PRIOR TO BUILDING DIVISION AUDIT. THE AFFIDAVIT
 PREDATES THE PAGES UPLOADED SO IT APPEARS THAT THEY
 HAVE NOT YET BEEN REVIEWED.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2022-01-20 Cont ID  
Sent By dbattles Date 2022-01-20 Time 08:50 Rev Time 0.00
Received By dbattles Date 2022-01-20 Time 08:50 Sent To  
Notes
2022-01-20 08:58:27OK-CREDENTIALS
 PLAN REVIEW AFFIDAVIT TO BE REVIEWED AFTER OTHER AGENCY
 REVIEW.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2022-08-01 Cont ID  
Sent By rmcphers Date 2022-08-01 Time 11:50 Rev Time 0.00
Received By rmcphers Date 2022-08-01 Time 11:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2022-10-04 Cont ID  
Sent By vbroglia Date 2022-10-04 Time 12:41 Rev Time 0.00
Received By vbroglia Date 2022-10-04 Time 12:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2022-07-06 Cont ID  
Sent By vbroglia Date 2022-07-06 Time 15:47 Rev Time 0.00
Received By vbroglia Date 2022-07-06 Time 15:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2022-05-31 Cont ID  
Sent By vbroglia Date 2022-05-31 Time 14:16 Rev Time 0.00
Received By vbroglia Date 2022-05-31 Time 14:16 Sent To  
Notes
2022-05-31 14:18:445/31/2022 FAILED
  
 MET WITH APPLICANT ON MAY 11 2022 AND NEW PLANS HAVE
 NOT BEEN PROPERLY UPLOADED TO THE PROJECTDOX PORTAL
 SHOWING NEW SITE PLAN LAYOUT
  
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-27 Cont ID  
Sent By vbroglia Date 2022-04-27 Time 11:18 Rev Time 0.00
Received By vbroglia Date 2022-04-27 Time 11:18 Sent To  
Notes
2022-04-27 12:55:104/27/2022 FAILED
  
  
 PLEASE NOTE THE NEW ADDITION WILL NOT FALL UNDER
 SECTION 94-515, SINCE IT WILL BE CONFORMING WITH
 TODAY'S CODE.
  
 PARKING:
 1) IF PROPOSING TO RELOCATE EXISTING PARKING SPACE,
 THEY WILL NEED TO COMPLY WITH TODAYS CODE
 2) GARAGE PARKING CANNOT ACOUNT FOR REQUIRED PARKING,
 SINCE IT IS CONSIDERED A NON-FUNCTIONAL GARAGE
 3) PARKING SPACE IN FRONT OF THE BUILDING (#8 LISTED IN
 PLANS) IS ALLOWED TO BE ACCOUNT FOR THE REQUIRED
 PARKING, BUT #7 CANNOT COUNT TOWARDS REQUIRED PARKING,
 SINCE IT IS NOT COMPLETELY IN FRONT OF THE BUILDING
 4) PARKING STRIPING NEEDS TO COMPLY WITH SECTION 94-485
 (J) TABLE "STALL PARKING DETAIL"
 5) A PARKING CURB WITH A 90 ANGEL REQUIRES A 24 FEET
 ASILE WIDTH PLEASE SEE SECTION 94-485 (J)(2) IF
 EXISTING ALLEY WIDTH DOES NOT COMPLY WITH MINIMUM AISLE
 REQUIREMENTS, ADDITIONAL PARKING SPACE AISLE OR
 SETBACKS SHALL BE REQUIRED AS INDICATED IN FIGURE XV-2.
 6) PLEASE FOLLOW TABLE VII-10 UNDER SECTION 94-210 FOR
 PARKING REQUIREMENTS
  
 HANDICAP STALL:
 IT IS UNCLEAR IF THE HATCHING IS AN OVER HANG OR GOING
 INTO THE HANDICAP WHITE STRIPINGS WHICH WOULD BE AN
 ISSUE IF THAT IS SCOPE OF WORK
  
 SETBACKS:
 PLEASE PROVIDE THE SETBACK SO THE NEW ADDITION
  
 OPEN SPACE:
 PLEASE PROVIDE THE PERCENTAGE OF OPEN SPACE PROVIDED
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By vbroglia Date 2022-02-23 Time 16:55 Rev Time 0.00
Received By vbroglia Date 2022-02-23 Time 16:55 Sent To  
Notes
2022-02-23 17:00:442/23/2022 FAILED
  
 PLEASE SHOW WHERE THE MECHANICAL EQUIPMENT IS LOCATED
  
 PLEASE SHOW THE SETBACKS AND PERCENTAGE OF OPEN SPACE
 REQUIRED/PROPOSED
  
 PLEASE APPLY FOR A LANDSCAPE PERMIT THAT OBTAINS A
 PERMIT NUMBER
  
 FOR LANDSCAPE QUESTION PLEASE CONTACT OUR LANDSCAPE
 PLANNER CONTACT: RAY CARANCI 561 822 1462 OR
 [email protected]
  
 ADDITIONAL COMMENTS MAY OCCUR IN SECOND SUBMITTAL
  