Plan Review Details - Permit 22010426
Plan Review Stops For Permit 22010426
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-02-14 Cont ID  
Sent By cpuell Date 2022-02-14 Time 13:23 Rev Time 0.00
Received By cpuell Date 2022-02-14 Time 13:23 Sent To  
Notes
2022-02-14 13:24:05A SECOND PERMIT WAS ISSUE FOR THE REAR BUILDING UNDER
 22020642.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-02-04 Cont ID  
Sent By cpuell Date 2022-02-04 Time 15:12 Rev Time 0.00
Received By cpuell Date 2022-02-04 Time 15:12 Sent To  
Notes
2022-02-04 15:13:56THIS PERMIT IS FOR THE FRONT SOUTH BLDG ONLY, A SECOND
 PERMIT IS REQUIRED FOR THE REAR BUILING. HALF ADDRESS
 READDRESSED FROM 611 1/2 EL VEDADO TO 613 EL VEDADO.
 PLEASE EMAIL [email protected] ONCE SECOND PERMIT IS
 APPLIED FOR.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-01-14 Cont ID  
Sent By cpuell Date 2022-01-14 Time 08:50 Rev Time 0.00
Received By cpuell Date 2022-01-14 Time 08:50 Sent To  
Notes
2022-01-14 08:51:13WHICH BUILDING IS THE WORK TO BE DONE, NORTH OR SOUTH?
 THE NORTH BUILDING HAS A HALF ADDRESS WHICH WILL NEED
 TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS THE
 HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-22 Cont ID  
Sent By jbrooks Date 2022-02-22 Time 11:58 Rev Time 0.00
Received By jbrooks Date 2022-02-22 Time 07:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-18 Cont ID  
Sent By jbrooks Date 2022-01-18 Time 08:59 Rev Time 0.00
Received By jbrooks Date 2022-01-18 Time 07:31 Sent To  
Notes
2022-01-18 08:59:59JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL10497-R8 SELECTED SYSTEM NO. W-104 DO NOT
 MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN
 PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM
 NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE
 SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR
 ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 2. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT
 COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL
 AND CHAPTER 11 OF THE 2020 FBC-PLUMBING
 3. FBC EB 706.6 PROVIDE A FLASHING DETAIL DRAWING FOR
 THE EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL
 HEIGHT(S).
 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND REMOVE REFERENCE TO REAR BUILDING.
 5. FBC B 107.2.1 SEPARATE PERMIT REQUIRED FOR REAR
 BUILDING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-22 Cont ID  
Sent By jbrooks Date 2022-02-22 Time 11:58 Rev Time 0.00
Received By jbrooks Date 2022-02-11 Time 12:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-18 Cont ID  
Sent By jbrooks Date 2022-01-18 Time 09:00 Rev Time 0.00
Received By jbrooks Date 2022-01-14 Time 07:43 Sent To  
Notes
***NONE***