|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22010393
Plan Review Stops For Permit 22010393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-28 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-28 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-07 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-07 |
Time |
15:52 |
Sent To |
|
|
Notes |
2022-02-07 16:42:37 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE PROVIDE CONNECTION & MATERIAL | | DETAILS INCLUDING FOUNDATION/WALL ANCHORING, FRAME WORK | | SIZES & CONNECTIONS, ALL ANCHOR/FASTENER DETAILS. | | FBC R 301.2.1.1.1.1, PLEASE PROVIDE ENGINEER APPROVED | | (SIGNED/SEALED)DESIGN WINDLOAD INFORMATION FOR THIS | | STRUCTURE (ALUMINUM). |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-02-28 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-28 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-22 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-02-18 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-01-13 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-28 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-28 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-02-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-02-07 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-07 |
Time |
15:52 |
Sent To |
|
|
Notes |
2022-02-07 16:45:16 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | SIGNATURE REVIEW DENIED: | | | | STRUCTURAL FRAMING AND WINDLOAD DETAILS NEED TO BE | | SIGNED/SEALED BY DESIGN PROFESSIONAL. | | | | SIGNATURE REVIEW DENIED: | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-02-18 |
Time |
|
Rev Time |
|
Received By |
asangele |
Date |
2022-02-18 |
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |