Plan Review Details - Permit 22010262
Plan Review Stops For Permit 22010262
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-02-14 Cont ID  
Sent By cpuell Date 2022-02-14 Time 14:55 Rev Time 0.00
Received By cpuell Date 2022-02-14 Time 14:55 Sent To  
Notes
2022-02-14 14:55:36THIS PERMIT IS FOR THE SOUTH BUILDING ONLY - ADDRESS
 APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-08-01 Cont ID  
Sent By cthroop Date 2022-08-01 Time 12:21 Rev Time 0.00
Received By cthroop Date 2022-08-01 Time 12:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By cthroop Date 2022-05-12 Time 17:11 Rev Time 0.00
Received By cthroop Date 2022-05-12 Time 11:18 Sent To  
Notes
2022-05-12 17:12:51PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SITE DRAINAGE PLAN WITH A BOUNDARY LINE
 SURVEY PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 2.ENERGY SUBMITTAL IS NOT SIGNED. PROVIDE AN ENERGY
 SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 PROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1. 1.SECTIONS R401 THROUGH R404.
 2. 2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED ?MANDATORY.?
  
 3. PLACE THE CEILING AND WALL INSULATION R VALUE ON
 PLANS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 14:25 Rev Time 0.00
Received By mpeterso Date 2022-06-30 Time 14:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-03-30 Cont ID  
Sent By mpeterso Date 2022-03-30 Time 15:14 Rev Time 0.00
Received By mpeterso Date 2022-03-30 Time 15:14 Sent To  
Notes
2022-03-30 15:19:44ELECTRIC REVIEW FAILED
 1) PLANS DO NOT DETAIL ELECTRIC PANEL AND METER
 LOCATIONS. PLEASE CLARIFY. FBC 107.2
 2) UNCLEAR FROM RISER DIGRAM AND PANEL SCHEDULE
 HOW/WHICH CIRCUITS ARE FED TO GUEST HOUSE. PLEASE
 CLARIFY FBC 107.2 NEC 215.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-01 Cont ID  
Sent By cthroop Date 2022-08-01 Time 12:21 Rev Time 0.00
Received By cthroop Date 2022-06-28 Time 06:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-12 Cont ID  
Sent By cthroop Date 2022-05-12 Time 17:11 Rev Time 0.00
Received By cthroop Date 2022-03-09 Time 10:38 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-09-08 Cont ID  
Sent By lmarchan Date 2022-09-08 Time 08:35 Rev Time 0.00
Received By lmarchan Date 2022-08-03 Time 11:24 Sent To  
Notes
2022-09-08 08:35:34NO IMPACT FEES DUE. LEM
2022-08-03 11:24:458/3/22 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By cthroop Date 2022-05-12 Time 17:10 Rev Time 0.00
Received By cthroop Date 2022-05-12 Time 11:18 Sent To  
Notes
2022-05-12 17:11:22IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-29 Cont ID  
Sent By medwards Date 2022-06-29 Time 17:03 Rev Time 0.00
Received By medwards Date 2022-06-29 Time 17:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-17 Cont ID  
Sent By medwards Date 2022-03-17 Time 13:52 Rev Time 0.00
Received By medwards Date 2022-03-17 Time 13:52 Sent To  
Notes
2022-03-17 13:52:441ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22010262
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE RETURN AIR PATH AT THE AHU. IS THERE
 A LOUVERED DOOR AT THE MECHANICAL CLOSET? FBC RES M1602
  
 2) PLEASE PROVIDE THE DUCT SIZES ON ALL OF THE SUPPLY
 DUCTS. FBC 107.2.1
  
 3) PLEASE SHOW THE CONDENSING UNIT LOCATION ON THE
 PROPERTY. FBC 107.2.1
  
 4) PLEASE SHOW THE CONDENSATION PIPING MATERIAL, SIZE
 AND TERMINATION LOCATION. FBC RES M1411.3
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-03-10 Cont ID  
Sent By lcrespo Date 2022-03-10 Time 12:20 Rev Time 0.00
Received By lcrespo Date 2022-03-10 Time 12:20 Sent To  
Notes
2022-03-10 12:20:5503/10/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE PROVIDE A PLUMBING ISOMETRIC RISER
 DIAGRAM PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.3.5.3 (12) RESIDENTIAL PLUMBING.
  
 2. WOULD YOU PLEASE PROVIDE A SOURCE OF HOT WATER AND
 THE LOCATION OF CONNECTION PER THE 2020 FBC SEC. FBC R
 2722.2.
  
 3. THESE ARE MULTI-FAMILY DWELLINGS, AND WATER USERS
 WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION
 ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW
 ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF
 HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE
 BACKFLOW DEVICE WILL BE REQUIRED AT THE WATER METER PER
 THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND
 THEIR CONNECTION CONTROL PROGRAM.
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By cthroop Date 2022-05-12 Time 17:11 Rev Time 0.00
Received By cthroop Date 2022-05-12 Time 11:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 14:55 Rev Time 0.00
Received By mpeterso Date 2022-06-30 Time 14:55 Sent To  
Notes
2022-06-30 14:56:09ALL PLANS PASSED SIGNATURE REVIEW
2022-06-29 17:04:22MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By cthroop Date 2022-05-12 Time 17:11 Rev Time 0.00
Received By cthroop Date 2022-05-12 Time 11:18 Sent To  
Notes
2022-03-17 13:54:36DIGITAL SIGNATURE FOR MECHANICAL APPROVED.
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-03-16 Cont ID  
Sent By asangele Date 2022-03-16 Time 12:24 Rev Time 0.00
Received By asangele Date 2022-03-16 Time 12:24 Sent To  
Notes
***NONE***