Plan Review Details - Permit 22010260
Plan Review Stops For Permit 22010260
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-02-25 Cont ID  
Sent By cpuell Date 2022-02-25 Time 12:34 Rev Time 0.00
Received By cpuell Date 2022-02-25 Time 12:34 Sent To  
Notes
2022-02-25 12:34:39ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-08-02 Cont ID  
Sent By pvalenti Date 2022-08-02 Time 11:28 Rev Time 0.00
Received By pvalenti Date 2022-08-02 Time 11:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-22 Cont ID  
Sent By pvalenti Date 2022-07-22 Time 10:59 Rev Time 0.00
Received By pvalenti Date 2022-07-22 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-06-22 Cont ID  
Sent By cthroop Date 2022-06-22 Time 15:35 Rev Time 0.00
Received By cthroop Date 2022-06-21 Time 16:28 Sent To  
Notes
2022-06-22 15:37:34PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED. (#6
 HAS BEEN CORRECTED)
  
  
 1. SUBMITTAL SHEETS 10 AND 11 ARE BOTH LABLED PLAN PAGE
 S3.0.
 SHEET 10 IS A FOUNDATION PLAN AND SHEET 11 IS A ROOF
 FRAMING PLAN.
 EACH PLAN PAGE SHALL BEAR A SEPERATE PAGE NUMBER.
 PLEASE CLARIFY
 PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES.
  
 2. DETAIL TAGS ON SUBMITTAL SHEET 014, FOUNDATION PLAN
 LABLED S1.0, REFERENCES PLAN PAGE S4.0.
 NO PLAN PAGE S4.0 HAS BEEN SUBMITTED FOR REVIEW.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. DETAIL TAG ON SUBMITTAL SHEET 014, FOUNDATION PLAN
 LABLED S1.0, REFERENCES DETAIL 2/S2.0.
 DETAIL 2/S2.0 IS FOR THE 2ND FLOOR TIE-BEAM.
 PLEASE CLARIFY.
 PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES.
  
 4. FOUNDATION PLAN PAGE S1.0 INDICATES THIS WILL BE A
 SLAB ON GRADE FOUNDATION (SOG).
 FOUNDATION DETAILS ON PLAN PAGE S3.0 INDICATES THIS
 WILL BE AN ELEVATED SLAB ON STEM WALLS.
 PLEASE CLARIFY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5. PROVIDE A ROOF DRAINAGE PLAN. (FLAT ROOF WITH
 PARAPETS)
 R903.4ROOF DRAINAGE.
 UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF
 DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
 ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL
 BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR
 PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY
 THE ROOF SLOPE AND CONTRIBUTING ROOF AREA.
  
 6.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-04 Cont ID  
Sent By cthroop Date 2022-05-04 Time 11:58 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 15:18 Sent To  
Notes
2022-05-04 12:24:54PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SUBMITTAL SHEETS 10 AND 11 ARE BOTH LABLED PLAN PAGE
 S3.0.
 SHEET 10 IS A FOUNDATION PLAN AND SHEET 11 IS A ROOF
 FRAMING PLAN.
 EACH PLAN PAGE SHALL BEAR A SEPERATE PAGE NUMBER.
 PLEASE CLARIFY
 PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES.
  
 2. DETAIL TAGS ON SUBMITTAL SHEET 014, FOUNDATION PLAN
 LABLED S1.0, REFERENCES PLAN PAGE S4.0.
 NO PLAN PAGE S4.0 HAS BEEN SUBMITTED FOR REVIEW.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. DETAIL TAG ON SUBMITTAL SHEET 014, FOUNDATION PLAN
 LABLED S1.0, REFERENCES DETAIL 2/S2.0.
 DETAIL 2/S2.0 IS FOR THE 2ND FLOOR TIE-BEAM.
 PLEASE CLARIFY.
 PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES.
  
 4. FOUNDATION PLAN PAGE S1.0 INDICATES THIS WILL BE A
 SLAB ON GRADE FOUNDATION (SOG).
 FOUNDATION DETAILS ON PLAN PAGE S3.0 INDICATES THIS
 WILL BE AN ELEVATED SLAB ON STEM WALLS.
 PLEASE CLARIFY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5. PROVIDE A ROOF DRAINAGE PLAN. (FLAT ROOF WITH
 PARAPETS)
 R903.4ROOF DRAINAGE.
 UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF
 DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
 ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL
 BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR
 PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY
 THE ROOF SLOPE AND CONTRIBUTING ROOF AREA.
  
 6. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED ICYNENE
 SPRAY FOAM INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-14 Cont ID  
Sent By cthroop Date 2022-04-14 Time 16:14 Rev Time 0.00
Received By cthroop Date 2022-04-12 Time 12:45 Sent To  
Notes
2022-04-14 16:23:38PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THERE ARE TWO ENERGY SUBMITTALS SUBMITTED FOR
 REVIEW. REMOVE ONE AND LEAVE THE ONE YOU WANT REVIEWED.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2..DESIGNER SHALL PLACE THE CEILING AND WALL INSULATION
 R-VALUE ON PLANS.
 R402.1.2INSULATION AND FENESTRATION CRITERIA.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE R402.1.2, BASED ON THE CLIMATE
 ZONE SPECIFIED IN CHAPTER 3.
  
 3. PROVIDE THE FLORIDA PRODUCT APPROVAL OR UL DESIGN
 FOR THE PROPOSED ROOF HATCH.
 PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT APPROVAL
 OR MIAMI-DADE NOA, APPROVED UNDER THE 2020 FBC, FOR THE
 PROPOSED ROOF HATCH.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 4. IDENTIFY THE WINOW AND DOOR TYPE ON THE PLANS. PLACE
 IT NEXT TO EACH OPENING AND COORDINATE WITH THE WINDOW
 AND DOOR SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5.PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FIGURE
 R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES.
 R301.2.1.1WIND DESIGN REQUIRED.
  
 6.PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER
 CALCULATED DESIGN PRESSURES.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-05-11 Cont ID  
Sent By fgiaquin Date 2022-05-11 Time 23:44 Rev Time 0.00
Received By fgiaquin Date 2022-05-11 Time 21:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-03-16 Cont ID  
Sent By fgiaquin Date 2022-03-16 Time 20:18 Rev Time 0.00
Received By fgiaquin Date 2022-03-16 Time 18:39 Sent To  
Notes
2022-03-16 20:18:04ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SEVERAL RECEPTACLE WALL SPACING VIOLATIONS IN
 OFFICE, FAMILY ROOM, LIVING ROOM, NEC 210.52
  
 2. SMOKE ALARMS OUTSIDE BEDROOMS MUST BE SMOKE/CARBON
 COMBO ALARMS AND WITHIN 10' OF BEDROOM DOORS. FBC-RE
 314 AND 315, NFPA 72
  
 3. RISER DIAGRAM SHOWS 250AMP METER CAN. A 250AMP METER
 CAN DOES NOT EXIST THERE IS A 200AMP METER CAN OR A
 320AMP CONTINUOUS METERCAN (400AMP) PLEASE SPECIFY
 EXACT METER CAN TO BE USED. NEC 110.3B FBC 107.2.1
  
 4. ON RISER DIAGRAM PLAN SHOWS 250AMP MAIN SERVICE
 DISCONNECTING MEANS AND PANEL A AS 250AMP M.L.O. PANEL
 BUT ON 1ST FLOOR POWER PLAN DRAWING IT SHOWS 200AMP
 MAIN SERVICE DISCONNECT SWITCH AND PANEL A AS 200AMPS.
 PLEASE PROVIDE ACCURATE AND CONSISTENT DRAWINGS. FBC
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2023-03-22 Cont ID  
Sent By rwbrown Date 2023-03-22 Time 13:40 Rev Time 0.00
Received By rwbrown Date 2023-03-22 Time 13:40 Sent To  
Notes
2023-03-22 13:41:23LUIS C PASSED AND STAMPED.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-08-02 Cont ID  
Sent By pvalenti Date 2022-08-02 Time 11:29 Rev Time 0.00
Received By pvalenti Date 2022-08-01 Time 16:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-22 Cont ID  
Sent By pvalenti Date 2022-07-22 Time 11:25 Rev Time 0.00
Received By pvalenti Date 2022-07-17 Time 08:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-23 Cont ID  
Sent By lmarchan Date 2022-06-23 Time 08:51 Rev Time 0.00
Received By lmarchan Date 2022-05-22 Time 15:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-11 Cont ID  
Sent By fgiaquin Date 2022-05-11 Time 23:44 Rev Time 0.00
Received By fgiaquin Date 2022-04-29 Time 13:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-14 Cont ID  
Sent By cthroop Date 2022-04-14 Time 16:23 Rev Time 0.00
Received By cthroop Date 2022-02-24 Time 08:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-06-27 Cont ID  
Sent By lmarchan Date 2022-06-27 Time 12:25 Rev Time 0.00
Received By lmarchan Date 2022-06-22 Time 09:42 Sent To  
Notes
2022-06-27 09:04:41MU-2022-028894 - $2491.56 PAID
2022-06-22 09:43:096/22/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-04-13 Cont ID  
Sent By cthroop Date 2022-04-13 Time 08:36 Rev Time 0.00
Received By cthroop Date 2022-04-13 Time 08:36 Sent To  
Notes
2022-04-13 08:37:44IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By medwards Date 2022-05-09 Time 17:21 Rev Time 0.00
Received By medwards Date 2022-05-09 Time 17:21 Sent To  
Notes
2022-05-09 17:23:16APPROVED WITH PRIVISO:
 THE RETURN IN THE OFFICE WILL NEED TO BE DUCTED TO THE
 RETURN OR HAVE A RETURN AIR DUCT TO THE OUTSIDE OF THE
 OFFICE DOORS. FRC M1602.3
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By medwards Date 2022-03-09 Time 06:38 Rev Time 0.00
Received By medwards Date 2022-03-09 Time 06:38 Sent To  
Notes
2022-03-09 06:38:531ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22010260
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE ARE 2 ENERGY CALCULATIONS SUBMITTED FOR THIS
 JOB. ONE IS DATED 12/06/2021 AND ONE IS DATED
 01/06/2022. THEY ARE TOTALLY DIFFERENT AS THE SQUARE
 FOOTAGE AND MECHANICAL SYSTEM SIZING ARE DIFFERENT FOR
 EACH DOCUMENT. PLEASE LET US KNOW WHICH DOCUMENT YOU
 NEED FOR US TO LOCK OUT IN THE SYSTEM. FBC 107.2.1
  
 2) PLEASE SHOW THE RETURN AIR PATH FROM THE 1ST FLOOR
 OFFICE BACK TO THE AHU WHEN THE POCKET DOORS ARE
 CLOSED. FBC RES M1602.3
  
 3) PLEASE MAKE SURE THAT THE MECHANICAL EQUIPMENT SIZES
 MATCH THE MECHANICAL EQUIPMENT SIZING CALCULATIONS THAT
 IS CHOSEN FOR THIS PROJECT. FBC EC R403.7.1.2.1
  
 4) THE DESIGNER OF THE MECHANICAL DRAWING MUST PRINT
 AND SIGN THEIR NAME IN THE TITLE BLOCK OF THE DOCUMENT.
 WPB AMENDMENT 107.2.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-03-02 Cont ID  
Sent By lcrespo Date 2022-03-02 Time 11:52 Rev Time 0.00
Received By lcrespo Date 2022-03-02 Time 11:52 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2022-06-22 Cont ID  
Sent By cthroop Date 2022-06-22 Time 14:23 Rev Time 0.00
Received By cthroop Date 2022-06-21 Time 16:28 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-05-04 Cont ID  
Sent By cthroop Date 2022-05-04 Time 11:53 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 15:19 Sent To  
Notes
2022-05-04 11:58:06ROOFING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 1. PRODUCT APPROVALS FL2533-R27 MODIFIED BITUMEN AND
 FL3443-R34 THERMOPLASTIC ROOF COVERING SUBMITTED FOR
 REVIEW.
 DESIGNER SHALL SELECT SYSTEM TO BE INSTALLED.
  
 NOTICE: IF SYSTEM SELECTED REQUIRES MECHANICALY
 ATTACHED BASE SHEET, PROVIDE ENHANCED FASTENER SCHEDULE
 PER LIMITATIONS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-04-13 Cont ID  
Sent By cthroop Date 2022-04-13 Time 09:37 Rev Time 0.00
Received By cthroop Date 2022-04-12 Time 12:45 Sent To  
Notes
2022-04-13 09:39:28ROOFING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER
 BARRIER PER FBC R905.1.1.
 UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL
 CONFORM TO THE APPLICABLE STANDARDS? AND SHALL BE
 APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION
 R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE.
  
 3. PRODUCT APPROVAL FL3443-R34 HAS EXPIRED.
 PROVIDE PRODUCT APPROVALS FOR ROOF COVERINGS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-08-02 Cont ID  
Sent By pvalenti Date 2022-08-02 Time 11:28 Rev Time 0.00
Received By pvalenti Date 2022-08-02 Time 11:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-07-22 Cont ID  
Sent By pvalenti Date 2022-07-22 Time 11:13 Rev Time 0.00
Received By pvalenti Date 2022-07-22 Time 09:00 Sent To  
Notes
2022-07-22 11:14:03PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 SIGNATURE REVIEW DENIED:
  
 CITY OF WPB AMENDMENTS & FBC B 107.2.1, PLAN SHEETS
 S3.0, S0.1, S0.2, & S2.0 ARE MISSING 3RD PARTY
 VERIFIABLE SIGNATURES AS PER REQUIREMENTS NOTED BELOW:
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-06-22 Cont ID  
Sent By cthroop Date 2022-06-22 Time 15:37 Rev Time 0.00
Received By cthroop Date 2022-06-21 Time 16:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-04 Cont ID  
Sent By cthroop Date 2022-05-04 Time 11:50 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 15:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-04-14 Cont ID  
Sent By cthroop Date 2022-04-14 Time 16:14 Rev Time 0.00
Received By cthroop Date 2022-04-12 Time 12:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By vbroglia Date 2022-05-09 Time 15:52 Rev Time 0.00
Received By vbroglia Date 2022-05-09 Time 15:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By vbroglia Date 2022-03-07 Time 10:44 Rev Time 0.00
Received By vbroglia Date 2022-03-07 Time 10:44 Sent To  
Notes
2022-03-07 10:51:063/7/2022 **** FAILED ****
  
  
 SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE,
 IRRIGATION, LANDSCAPE, DRIVEWAYS.
  
 PLEASE APPLY FOR A LANDSCAPE PERMIT THAT OBTAINS A
 PERMIT NUMBER TO ALLOW STAFF TO MOVE FOWARD.
 FOR LANDSCAPE QUESION PLEASE CONTACT RAY CARANCI AT 561
 822 1462 OR [email protected]
  
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  