Plan Review Details - Permit 22010192
Plan Review Stops For Permit 22010192
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-01-24 Cont ID  
Sent By cpuell Date 2022-01-24 Time 11:08 Rev Time 0.00
Received By cpuell Date 2022-01-24 Time 11:08 Sent To  
Notes
2022-01-24 11:09:40ADDRESS CHANGED FROM 2417 MEDIAN WAY TO 2441 MEDINA
 WAY, UPDATED PERMIT.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-01-19 Cont ID  
Sent By cpuell Date 2022-01-19 Time 16:04 Rev Time 0.00
Received By cpuell Date 2022-01-19 Time 16:04 Sent To  
Notes
2022-01-19 16:06:13ADDRESS RANGE NEEDS TO BE OPENED UP, NEW CONSTRUCTION
 PLAN FALLS INLINE WITH 2461, HOWEVER THE OWNER CAN PICK
 ANY ADDRESS FORM 2427 TO 2471 MEDINA WAY, PLEASE HAVE
 OWNER CONTACT ME TO DISCUSS ADDRESSING OPTIONS
 [email protected] OR CALL 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By jgomez Date 2022-07-06 Time 14:06 Rev Time 0.00
Received By jgomez Date 2022-07-06 Time 13:15 Sent To  
Notes
2022-07-06 14:06:56BUILDING AUDIT OK WITH PROVISO:
 1-PROVIDE PRODUCT APPROVAL FOR:
 A) INSWING ENTRY DOOR AS SHOWN ON PLANS.
 NOTE: CUSTOM DOOR WILL NEED A COMPLETE SITE SPECIFIC
 PRODUCT APPROVAL ENGINEERING ANALYSIS FOR BUILDING
 OFFICIAL APPROVAL.
 B)ROOF TILE ADHESIVE LISTED ON THE ROOF TILE NOA
  
 2- PROVIDE SHOP DRAWINGS FOR THE GUARDRAILS
 CONSTRUCTION, INCLUDING THE TERRACOTTA BARREL TILE
 BALCONY GUARDRAILS.
 NOTE: REVIEWED/APPROVED BY THE DESIGNER OF RECORD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-24 Cont ID  
Sent By jgomez Date 2022-06-24 Time 19:55 Rev Time 0.00
Received By jgomez Date 2022-06-24 Time 13:47 Sent To  
Notes
2022-06-24 19:56:01NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING AUDIT
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22010192
  
 1- OK.
 2- OK.
  
 ORIGINAL COMMENT:
 3- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4
 FBC-RESIDENTIAL.
  
 RESPONSE:
 A)REPORT SUBMITTED HAS THE WRONG ADDRESS. THIS ADDRESS
 IS 2441 MEDINA WAY NOT 2717 MEDINA WAY. REVISE AS
 REQUIRED.
  
 B)REPORT IS A PRELIMINARY REPORT AND IS INCONCLUSIVE.
 NEED FINAL REPORT WITH LAND PREPARATION AND FOOTING
 RECOMMENDATION.
  
 C)REPORT SUBMITTED HAS A COPY OF THE ENGINEER
 SEAL/SIGNATURE. EITHER SUBMIT REPORT ELECTRONICALLY
 WITH A VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD
 COPY WITH ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 61G15-23.003 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 ORIGINAL COMMENT:
 4- NEED BATHROOM ON THE FIRST FLOOR WITH MAXIMUM
 POSSIBLE PRIVACY AND A DOOR THAT PROVIDES 29" MIN.
 CLEAR OPENING AS REQUIRED BY SEC. R320.1.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 RESPONSE LETTER STATES "PLEASE SEE REVISED PLAN A/1.01
 FOR DOOR #107A, SHOWN AS 2'-10 WIDE". DOOR #107A
 CORRESPONDS TO THE POWDER ROOM.
 THERE ARE COMPLETE BATHROOMS ON THE FIRST FLOOR. NEED A
 COMPLETE BATHROOM WITH MAXIMUM POSSIBLE PRIVACY AND A
 DOOR THAT PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED
 BY SEC. R320.1.1 FBC-RESIDENTIAL.
 ALSO, INTERIOR DOORS $ CASED OPENINGS SCHEDULE ON SHEET
 A7.02 SPECIFIES DOOR #107A WITH 2'-8" WIDE DOOR NOT
 2'-10" AS SPECIFIED ON THE RESPONSE LETTER.
  
 5- OK.
  
 ORIGINAL COMMENT:
 6- PLANS DON'T PROVIDE DETAILS AND SPECIFICATIONS FOR
 THE CONSTRUCTION OF BALCONY GUARDRAILS SHOWING
 COMPLIANCE WITH THE REQUIREMENTS OF SEC. R312.1
 FBC-RESIDENTIAL AND TABLE R301.5 FBC-RESIDENTIAL.
  
 RESPONSE:
 DESIGNER OF RECORD NEEDS TO PROVIDE THE DETAIL AND
 SPECIFICATIONS FOR THE CONSTRUCTION OF THE GUARDRAILS
 AS REQUIRED BY TABLE R301.5, SEC. R311.7.8 AND SEC.
 R312.1 FBC-RESIDENTIAL. SUBSEQUENT SHOP DRAWINGS ARE TO
 CONFIRM THAT DESIGN DETAILS AND SPECIFICATIONS ARE MET.
  
 ORIGINAL COMMENT:
 7- PLANS DON'T PROVIDE DETAILS AND SPECIFICATIONS FOR
 THE CONSTRUCTION OF THE TERRACOTTA BARREL TILE BALCONY
 GUARDRAILS SHOWING COMPLIANCE WITH THE REQUIREMENTS OF
 SEC. R312.1 FBC-RESIDENTIAL AND TABLE R301.5
 FBC-RESIDENTIAL.
  
 RESPONSE:
 SEE RESPONSE FOR ITEM #6 ABOVE.
  
  
 ORIGINAL COMMENT:
 8- NEED TO SPECIFY ATTIC ACCESSS SIZE AND LOCATION IN
 MASTER BEDROOM WING SHOWING COMPLIANCE WITH SEC. R807
 FBC-RESIDENTIAL.
  
 RESPONSE:
 SIZE OF ATTIC ACCESS DOESN'T COMPLY WITH THE ROUGH
 OPENING REQUIRED.
 NOTE: IN ORDER TO AVOID CONFLICTS/DELAYS PLEASE VERIFY
 ATTIC ACCESS PROPOSED LOCATION. IT LOOKS LIKE IT MAY
 NOT HAVE READY ACCES WITH THE CLOSET SHELVES BELOW IT.
 ALSO, THERE MAY NO BE ENOUGH HEADROOM AT THE ATTIC TO
 ACCESS MASTER BEDROOM AREA.
  
 9- OK.
 10-OK.
 11-OK.
  
 12-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
  
 A)INSWING ENTRY DOOR AS SHOWN ON PLANS.
 RESPONSE:
 WILL BE A DEFERRED SUBMITTAL.
 NOTE: CUSTOM DOOR WILL NEED A COMPLETE SITE SPECIFIC
 PRODUCT APPROVAL ENGINEERING ANALYSIS FOR BUILDING
 OFFICIAL APPROVAL. SIGNED AND SEALED.
  
 B)OK.
  
 C)FIXED WINDOW TYPE "C" AS SHOWN ON PLANS.
 RESPONSE:
 PRODUCT APPROVAL SUBMITTED DOESN'T COVER FIXED WINDOW
 TYPE "C" CONFIGURATION SHOWN ON PLANS.
  
 D)OK.
 E)OK.
 F)OK.
 G)OK.
  
 D) ROOF TILE ADHESIVE LISTED ON THE ROOF TILE NOA AND
 SPECIFY PADDY SIZE.
 RESPONSE:
 NOT SUBMITTED.
  
 13- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 14- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-20 Cont ID  
Sent By jgomez Date 2022-04-20 Time 17:15 Rev Time 0.00
Received By jgomez Date 2022-04-20 Time 14:45 Sent To  
Notes
2022-04-20 17:21:50NEW SINGLE FAMILY RESIDENCE (R3) BUILDING AUDIT
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22010192
  
 1- LOT DRAINAGE
 PROPOSED WORK AFFECTS THE LOT DRAINAGE. PROVIDE
 DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE IS KEPT
 WITHIN THE LOT AND NOT DIVERTED TO ADJACENT PROPERTIES.
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING SECTIONS: R401.3 FBC-RESIDENTIAL. SEC.
 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2- PROPOSED SITE PLAN PLAN SHOWS RETAINING WALLS. THESE
 WALLS ARE NOT PART OF THIS BUILDING PERMIT. SEPARATE
 PERMIT IS REQUIRED FOR THESE WALLS. SEC. 105.1 CITY
 AMENDMENTS.
  
 3- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4
 FBC-RESIDENTIAL.
  
 4- NEED BATHROOM ON THE FIRST FLOOR WITH MAXIMUM
 POSSIBLE PRIVACY AND A DOOR THAT PROVIDES 29" MIN.
 CLEAR OPENING AS REQUIRED BY SEC. R320.1.1
 FBC-RESIDENTIAL.
  
 5- PLANS DON'T PROVIDE DETAILS AND SPECIFICATIONS FOR
 THE CONSTRUCTION OF THE STAIRWAY SHOWING COMPLIANCE
 WITH THE REQUIREMENTS OF SEC. R311.7 FBC-RESIDENTIAL
 AND TABLE R301.5 FBC-RESIDENTIAL.
  
 6- PLANS DON'T PROVIDE DETAILS AND SPECIFICATIONS FOR
 THE CONSTRUCTION OF BALCONY GUARDRAILS SHOWING
 COMPLIANCE WITH THE REQUIREMENTS OF SEC. R312.1
 FBC-RESIDENTIAL AND TABLE R301.5 FBC-RESIDENTIAL
  
 7- PLANS DON'T PROVIDE DETAILS AND SPECIFICATIONS FOR
 THE CONSTRUCTION OF THE TERRACOTA BARREL TILE BALCONY
 GUARDRAILS SHOWING COMPLIANCE WITH THE REQUIREMENTS OF
 SEC. R312.1 FBC-RESIDENTIAL AND TABLE R301.5
 FBC-RESIDENTIAL.
  
 8- NEED TO SPECIFY ATTIC ACCESS SIZE AND LOCATION IN
 MASTER BEDROOM WING SHOWING COMPLIANCE WITH SEC. R807
 FBC-RESIDENTIAL.
  
 9-SHEET S-500:
 A)ENGINEER NEEDS TO UPDATE THE PRESSURE ZONES ON THE
 UPLIFT LOADS COMPONENTS & CLADDING DIAGRAM TO REFLECT
 THE CURRENT ZONES AS SHOWN ON FIGURE
 R301.2(7)FBC-RESIDENTIAL.
  
 B)ENGINEER NEEDS TO REVISE DIMENSION "A". FOOTNOTE "A"
 ON FIGURE R301.2(7)FBC-RESIDENTIAL REQUIRES THIS
 DISTANCE TO BE 4'-0" MIN.
  
 C)USING TABLE R301.2(2)FBC-RESIDENTIAL AS A REFERENCE,
 IT LOOKS LIKE THE UPWARD DESIGN PRESSURES SPECIFIED FOR
 ROOF ZONES 1 AND 2 ARE LOW. REVISE AS REQUIRED OR
 PROVIDE CALCULATIONS SHOWING WHY THEY ARE SO LOW
 COMPARED TO THE REVISED 2020 FBC-RESIDENTIAL TABLE.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 10- WINDOWS AND DOORS DESIGN PRESSURES SPECIFIED ON
 DRAWINGS S100 AND S200 ARE LOW FOR OPENINGS LOCATED ON
 THE END ZONE (NOTE: SEE ITEM #9(B) FOR MINIMUM END ZONE
 DIMENSION). REVISE AS REQUIRED OR PROVIDE CALCULATIONS
 SHOWING WHY THEY ARE SO LOW COMPARED TO THE REVISED
 2020 FBC-RESIDENTIAL TABLE. SEC. 107.2.1.2 CITY
 AMENDMENTS.
  
 11- REVISE ROOF SHEATHING NAILING SPECIFICATIONS TO
 COMPLY WITH NEW 2020 FBC-RESIDENTIAL SPECIFICATIONS.
 REVISED NAIL SPACING TO COMPLY TABLE R803.2.3.1
 FBC-RESIDENTIAL.
 NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS
 SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR
 EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM
 REQUIREMENTS.
  
 12-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 B)FAMILY ROOM SECTIONAL DOORS THAT MEET THE CALCULATED
 DESIGN PRESSURES. FLORIDA PRODUCT APPROVAL FL27023-R1
 SUBMITTED DOESN'T MEET THOSE PRESSURES.
 NOTE: PRODUCT APPROVAL SUBMITTED IS FOR NON-IMPACT
 DOORS. HURRICANE SHUTTERS PRODUCT APPROVAL AND COMPLETE
 INSTALLATION SCHEDULE WILL BE REQUIRED.
  
 C)FIXED WINDOW TYPE "C" AS SHOWN ON PLANS.
  
 D)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY DESIGN PRESSURES. SEC. R301.2.1
 FBC-RESIDENTIAL).
  
 E)ROOFING UNDERLAYMENT SPECIFIED ON PLANS. AND, CLEARLY
 SPECIFY SELECTED ASSEMBLY TO BE INSTALLED.
  
 F)HIP & RIDGE METAL SUPPORT TO BE USED FOR ROOF TILES.
  
 G)ROOF TILE NOA SUBMITTED: CLEARLY SPECIFY ADHESIVE
 PARTY SIZE AS REQUIRED BY CITY POLICY FOR ALL ROOFING
 PERMITS TO VERIFY UPLIFT. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 H)ROOF TILE ADHESIVE LISTED ON THE ROOF TILE NOA AND
 SPECIFY PADDY SIZE.
  
 NOTE FOR FLORIDA PRODUCT APPROVALS SUBMITTALS:
 PLEASE DON'T SEPARATE THE PRODUCT APPROVAL. COMPLETE
 PRODUCT APPROVAL (FLORIDA PRODUCT APPROVAL COVER PAGE
 AND INSTALLATION INSTRUCTIONS) SHOULD BE UPLOADED IN
 THE SAME PDF FILE FOR EACH PRODUCT.
  
 13- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 14- PROVIDE SURVEY SHOWING THE PROPOSED HOUSE AS
 REQUIRED BY SEC. 107.2.5 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-04-18 Cont ID  
Sent By jleahy Date 2022-04-18 Time 15:48 Rev Time 0.00
Received By jleahy Date 2022-04-15 Time 08:23 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-06-21 Cont ID  
Sent By ccole Date 2022-06-21 Time 15:01 Rev Time 0.00
Received By ccole Date 2022-06-21 Time 14:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-04-15 Cont ID  
Sent By ccole Date 2022-04-15 Time 17:18 Rev Time 0.00
Received By ccole Date 2022-04-15 Time 17:18 Sent To  
Notes
2022-04-15 17:19:24FBC-2020 RES. GAS AUDIT
 PERMIT- 22010192
 4/15/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
  
 AUDIT RESULTS.
  
 1) MANUFACTURER'S SPECIFICATIONS FOR THE FIREPLACE,
 DRYER, RANGE & LAMPS NOT SUBMITTED- SECS. G2435.1,
 G2438. G2447, & G2450.1 FBC RES.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By fmittner Date 2022-07-06 Time 14:15 Rev Time 0.00
Received By fmittner Date 2022-07-06 Time 14:15 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-03-25 Cont ID  
Sent By fmittner Date 2022-03-25 Time 11:39 Rev Time 0.00
Received By fmittner Date 2022-03-25 Time 11:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-01-26 Cont ID  
Sent By fmittner Date 2022-01-26 Time 12:26 Rev Time 0.00
Received By fmittner Date 2022-01-26 Time 12:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2022-07-06 Cont ID  
Sent By jgomez Date 2022-07-06 Time 14:27 Rev Time 0.00
Received By jgomez Date 2022-07-01 Time 15:42 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2022-06-24 Cont ID  
Sent By jgomez Date 2022-06-24 Time 20:21 Rev Time 0.00
Received By jgomez Date 2022-06-09 Time 09:30 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2022-06-14 Cont ID  
Sent By pvalenti Date 2022-06-14 Time 11:33 Rev Time 0.00
Received By pvalenti Date 2022-06-10 Time 15:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-06-13 Cont ID  
Sent By shill Date 2022-06-10 Time 15:44 Rev Time 0.00
Received By shill Date 2022-06-09 Time 07:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-04-20 Cont ID  
Sent By jgomez Date 2022-04-20 Time 17:54 Rev Time 0.00
Received By jgomez Date 2022-04-04 Time 08:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-04-01 Time   Rev Time 0.00
Received By aoliver Date 2022-03-31 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-29 Cont ID  
Sent By medwards Date 2022-03-29 Time 10:56 Rev Time 0.00
Received By medwards Date 2022-03-25 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-03-25 Time   Rev Time 0.00
Received By aoliver Date 2022-03-08 Time 16:14 Sent To  
Notes
2022-03-11 10:05:10NEW PRODUCT APPROVALS, NEW PLANS INCLUDING SITE PLAN
 SUBMITTED
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-27 Cont ID  
Sent By shill Date 2022-01-27 Time 15:32 Rev Time 0.00
Received By shill Date 2022-01-18 Time 06:31 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2022-07-12 Cont ID  
Sent By lmarchan Date 2022-07-12 Time 10:42 Rev Time 0.00
Received By lmarchan Date 2022-07-06 Time 14:39 Sent To  
Notes
2022-07-09 09:55:327/9/22 MU-2022-031286-0000 $459.33 PAID AO
2022-07-06 14:40:047/6/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-06-24 Cont ID  
Sent By jgomez Date 2022-06-24 Time 20:08 Rev Time 0.00
Received By jgomez Date 2022-06-24 Time 20:08 Sent To  
Notes
2022-06-24 20:08:31IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-04-20 Cont ID  
Sent By jgomez Date 2022-04-20 Time 17:30 Rev Time 0.00
Received By jgomez Date 2022-04-20 Time 17:29 Sent To  
Notes
2022-04-20 17:30:51IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-04-08 Cont ID  
Sent By medwards Date 2022-04-08 Time 08:51 Rev Time 0.00
Received By medwards Date 2022-04-08 Time 08:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-21 Cont ID  
Sent By ccole Date 2022-06-21 Time 15:02 Rev Time 0.00
Received By ccole Date 2022-06-21 Time 14:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-04-15 Cont ID  
Sent By ccole Date 2022-04-15 Time 17:00 Rev Time 0.00
Received By ccole Date 2022-04-15 Time 15:18 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 6 Status P Date 2022-07-06 Cont ID  
Sent By jgomez Date 2022-07-06 Time 13:14 Rev Time 0.00
Received By jgomez Date 2022-07-06 Time 12:31 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status P Date 2022-06-15 Cont ID  
Sent By pvalenti Date 2022-06-14 Time 11:19 Rev Time 0.00
Received By pvalenti Date 2022-06-14 Time 09:24 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status P Date 2022-04-08 Cont ID  
Sent By medwards Date 2022-04-08 Time 16:07 Rev Time 0.00
Received By medwards Date 2022-04-08 Time 16:07 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date 2022-03-31 Cont ID  
Sent By rmcphers Date 2022-03-31 Time 17:12 Rev Time 0.00
Received By rmcphers Date 2022-03-31 Time 17:12 Sent To  
Notes
2022-03-31 17:13:49PRIVATE PROVIDER AFFIDAVIT
  
 NEEDS CORRECTIONS
  
 1) DRAWING E2.00 HAS A REVISION DATE OF 02/24/2022 -
 PLEASE CORRECT ON THE AFFIDAVIT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2022-03-29 Time   Rev Time 0.00
Received By   Date 2022-03-29 Time   Sent To  
Notes
2022-03-29 10:55:49PP AFFIDAVIT AUDIT
  
 1) THE ELECTRICAL SHEETS SUBMITTED ARE NOT ON THE
 AFFIDAVIT.
 2) THE GAS APPLIANCES AND APPURTENANCES LISTED ON THE
 PP AFFIDAVIT WAS NOT IN THE SUPPORTING DOCUMENTS
 FOLDER.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2022-01-07 Cont ID  
Sent By dbattles Date 2022-01-07 Time 15:07 Rev Time 0.00
Received By dbattles Date 2022-01-07 Time 15:06 Sent To  
Notes
2022-01-27 15:34:22FS553.791, AFFIDAVITS REQUIRED PRIOR TO BUILDING
 DIVISION AUDIT.
  
2022-01-07 15:10:28OK-CREDENTIALS
 PLAN REVIEW AFFIDAVIT TO BE REVIEWED AFTER OTHER AGENCY
 REVIEW (ZONING).
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By jgomez Date 2022-07-06 Time 14:08 Rev Time 0.00
Received By jgomez Date 2022-07-06 Time 14:08 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-06-24 Cont ID  
Sent By jgomez Date 2022-06-24 Time 20:09 Rev Time 0.00
Received By jgomez Date 2022-06-24 Time 20:09 Sent To  
Notes
2022-06-24 20:11:36ROOFING AUDIT:
 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
  
 A) OK.
  
 B) OK.
  
 C) OK.
  
 D) ROOF TILE ADHESIVE LISTED ON THE ROOF TILE NOA AND
 SPECIFY PADDY SIZE.
 RESPONSE:
 NOT SUBMITTED.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-04-20 Cont ID  
Sent By jgomez Date 2022-04-20 Time 17:32 Rev Time 0.00
Received By jgomez Date 2022-04-20 Time 17:31 Sent To  
Notes
2022-04-20 17:35:04ROOFING AUDIT:
 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A) ROOFING UNDERLAYMENT SPECIFIED ON PLANS. AND,
 CLEARLY SPECIFY SELECTED ASSEMBLY TO BE INSTALLED.
  
 B) HIP & RIDGE METAL SUPPORT TO BE USED FOR ROOF TILES.
  
 C) ROOF TILE NOA SUBMITTED: CLEARLY SPECIFY ADHESIVE
 PARTY SIZE AS REQUIRED BY CITY POLICY FOR ALL ROOFING
 PERMITS TO VERIFY UPLIFT. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 D) ROOF TILE ADHESIVE LISTED ON THE ROOF TILE NOA AND
 SPECIFY PADDY SIZE.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By jgomez Date 2022-07-06 Time 14:09 Rev Time 0.00
Received By jgomez Date 2022-07-06 Time 13:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By jgomez Date 2022-06-24 Time 20:21 Rev Time 0.00
Received By jgomez Date 2022-06-24 Time 20:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-04-20 Cont ID  
Sent By jgomez Date 2022-04-20 Time 17:50 Rev Time 0.00
Received By jgomez Date 2022-04-20 Time 17:21 Sent To  
Notes
2022-04-08 08:52:58MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-06-10 Cont ID  
Sent By fmittner Date 2022-06-10 Time 11:26 Rev Time 0.00
Received By fmittner Date 2022-06-10 Time 11:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-03-25 Cont ID  
Sent By fmittner Date 2022-03-25 Time 11:39 Rev Time 0.00
Received By fmittner Date 2022-03-25 Time 11:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-01-26 Cont ID  
Sent By fmittner Date 2022-01-26 Time 12:26 Rev Time 0.00
Received By fmittner Date 2022-01-26 Time 12:26 Sent To  
Notes
***NONE***