Plan Review Details - Permit 22010157
Plan Review Stops For Permit 22010157
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-03-24 Cont ID  
Sent By lmarchan Date 2022-03-24 Time 13:46 Rev Time 0.00
Received By lmarchan Date 2022-03-24 Time 13:46 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-03-15 Cont ID  
Sent By jwitmer Date 2022-03-15 Time 08:37 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-15 08:37:41COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By jwitmer Date 2022-02-23 Time 13:11 Rev Time 0.00
Received By jwitmer Date 2022-02-23 Time 13:10 Sent To  
Notes
2022-02-23 13:11:15COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-03-15 Cont ID  
Sent By jwitmer Date 2022-03-15 Time 09:27 Rev Time 0.00
Received By jwitmer Date 2022-03-15 Time 08:34 Sent To  
Notes
2022-03-15 09:28:30WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22010157
 ADD: 2505 OKEECHOBEE BLVD SUITE E
 CONT: DESIGN FLOOR & HOME LLC
 TEL: 561-328-6255
 E-MAIL: ZACKP@DESIGNFLOORINGAND HOME.COM
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. MARCH 15TH/2022
 ACTION: PASSED/ BUILDING PROVISO
  
 PASSED/ BUILDING PROVISO, EXISTING. SHEET 10.3
 ACCESSIBILITY DETAILS. THE HIGH-LOW DRINKING FOUNTAIN
 SHOWS 4 DETAILS FOR EITHER ALCOVE OR BARRIERS, BUT
 SHEETS 10.5 AND 12.1 DO NOT SHOW EITHER BARRIERS OR
 ALCOVES FOR THE DRINKING FOUNTAINS. 2020 FL ACCESS.
 CODE. PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2.
 OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT
 MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT PROTRUDE
 MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION
 PATH.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
  
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By jwitmer Date 2022-02-23 Time 14:42 Rev Time 0.00
Received By jwitmer Date 2022-02-23 Time 13:10 Sent To  
Notes
2022-02-23 13:11:51WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22010157
 ADD: 2505 OKEECHOBEE BLVD SUITE E
 CONT: STOCKTON MAINTENANCE
 TEL: 800-207-0000
 E-MAIL: [email protected] BETH KERR
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. FEB. 23RD/2022
 ACTION: DENIED
  
 1) SHEET 10.5 OCCUPANCY & EGRESS FLOOR PLAN:
 1A) EXITING FOR THE MERCANTILE AREA SHOWS A FRONT PAIR
 OF DOORS AND A SIDE DOOR, PLEASE CONTINUE THE EXIT
 DISCHARGE TO THE PUBLIC WAY. CONCERNS ARE WITH EXIT
 DISCHARGE COMPONENTS SECTION 1028.3 OF THE 2020
 FBC-BUILDING.
  
 1B) PART OF THE EXIT DISCHARGE THAT ALSO NEEDS TO BE
 ANSWERED IS WITH SECTION 1028.4.1 2020 FBC-BUILDING
 CODE WIDTH AND COMPACITY, THE WIDTH OF THE EXIT
 DISCHARGE IS NOT SHOWN TO THE PUBLIC WAY.
  
 1C) NOTE ONLY. THE CURRENT VERSION OF THE FLOOR PLAN
 DOES NOT SHOW ANY OF THE MERCANTILE OCCUPANT LOAD GOING
 THROUGH THE STOCKROOM FOR EXITING, IF SO SECTION 1016.2
 .5 EXCEPTION 2 EGRESS THROUGH STOCKROOMS IN MERCANTILE
 OCCUPANCIES 2.1-2.4 HAVE TO BE ADHERED TOO.
  
 1D) BACK OF HOUSE TOP OF THE PLAN APPEARS TO BETAKING
 AS A BUSINESS OCCUPANCY. PLEASE NOTE THE OCCUPANT LOAD
 FACTOR HAS CHANGED TO 150 SQ. FT./ OCCUPANT SEE TABLE
 1004.5.
  
 1E) THE EGRESS PLAN DOES NOT SHOW ANY MERCANTILE RACKS,
 KIOSK, SALES COUNTERS, AISLE WIDTHS AND DRESSING ROOMS.
 IF ANY. 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES. CONSTRUCTION DOCUMENTS
 SHALL BE SUFFICIENT CLARITY TO INDICATE THE LOCATION,
 NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 1F) PLEASE NOTE NON FIXED AND MOVABLE FIXTURES, CASES,
 RACKS, AND COUNTERS NOT OVER 5 FEET 9 INCHES IN HEIGHT
 DO NOT REQUIRE PERMITS. RACK STORAGE OVER 5 FEET 9
 INCHES DOES REQUIRE A PERMIT.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION SECTION 105.2.
  
 2) SHEET 0.3 ACCESSIBILITY DETAILS;
 2A) DETAIL REAR WALL GRAB BAR A WATER CLOSET MISSING
 CENTERLINE TO SIDE WALL MEASUREMENT. 2020 ACCESS. CODE
 604.2 LOCATION 16? -18? CENTERLINE.
  
 2B) SIDE WALL GRAB BAR AT WATER CLOSET DOES NOT
 INDICATE THE LOCATION OF THE TOILET PAPER DISPENSER.
 2020 ACCESS. CODE TOILET PAPER DISPENSERS. 604.7. THE
 TOILET PAPER DISPENSER SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM TO 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM
 AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL
 NOT BE LOCATED BEHIND THE GRAB BARS.
  
 3) SHEET 10.3 ACCESSIBILITY DETAILS. THE HIGH-LOW
 DRINKING FOUNTAIN SHOWS 4 DETAILS FOR EITHER ALCOVE OR
 BARRIERS, BUT SHEETS 10.5 AND 12.1 DO NOT SHOW EITHER
 BARRIERS OR ALCOVES FOR THE DRINKING FOUNTAINS. 2020 FL
 ACCESS. CODE. PROTRUDING OBJECTS 307.2 PROTRUSION
 LIMITS 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27
 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR
 SHALL NOT PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO
 THE CIRCULATION PATH.
  
 4) SHEET 15.1 FINISH PLAN:
 4A) THE FINISH SCHEDULE DOES NOT APPEAR TO BE COMPLETE,
 EXAMPLE THE RESTROOMS ALL SHOW THE WALLS AS A P2 OR P8
 BUT THERE IS NO REFERENCE TO WHAT THEY MEAN. 2020 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION 107.2.1.
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES.
  
 4B) 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS
 COMMENT IS A RESULT OF THE BUILDING OFFICIAL
 INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS &
 SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED
 A SMOOTH HARD, NON-ABSORBENT SURFACE.
  
 4B)(1) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A
 TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 4B)(2) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET
 WALLS SHALL COMPLY WITH 1210.2.
  
 4B)(3) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS
 AND PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY
 WITH SECTIONS 1210.1 THROUGH 1210.4.
  
 5) SHEET 16.1 SHOWS NEW STOREFRONT GLAZING TO MATCH
 EXISTING. THIS REVIEW THERE WAS NO WIND DESIGN CRITERIA
 PROVIDED. 2020 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 5.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 5.2. RISK CATEGORY.
  
 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1.
  
 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 5.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 5.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 6A) COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS
 AND CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 6B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 6C) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE
 OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 6D) 107.3.4.2 DEFERRED SUBMITTALS VERSES COMPLYING WITH
 6A, 6B & 6C BEFORE PERMIT ISSUANCE. 107.3.4.2 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 7) SHEET 17.1 DOOR SCHEDULE VESTIBULE DOORS 100 DOOR
 TYPE SF2 NOTE 2 STATES THE GLASS DOOR MANUFACTURER TO
 VERIFY & SUPPLY THE CORRECT DOOR HARDWARE. SHOW
 COMPLIANCE WITH 1010.1.10 PANIC OR FIRE EXIT HARDWARE
 FOR ALL EXIT DOORS.
  
 8) SHEET 18.5 DETAIL 2 THE CASH WRAP DOES NOT HAVE
 HEIGHTS GIVEN FOR ACCESSIBILITY REQUIREMENTS. 2020
 ACCESS. CODE 904.3.3 CHECK WRITING SURFACES. WHERE
 PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH
 902.3HEIGHT.
 THE TOPS OF WORK SURFACES SHALL BE 28 INCHES MINIMUM
 AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
 SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL
 APPROACH TO AN ELEMENT.
  
 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS AND
 SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2.
 THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL EXTEND
 THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP.
  
 9) THERE ARE NO PLANS SHOWING IF THERE IS TO BE
 EXISTING ROOF TOP EQUIPMENT REPLACED OR IF THERE IS TO
 BE ANY NEW ROOF AIR HANDLERS INSTALLED WITH NEW ROOF
 OPENINGS. 2020 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES. CONSTRUCTION DOCUMENTS
 SHALL BE SUFFICIENT CLARITY TO INDICATE THE LOCATION,
 NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2022-04-06 Cont ID  
Sent By jleahy Date 2022-04-06 Time 14:07 Rev Time 0.00
Received By jleahy Date 2022-04-06 Time 14:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-03-30 Cont ID  
Sent By jleahy Date 2022-03-30 Time 14:51 Rev Time 0.00
Received By jleahy Date 2022-03-30 Time 13:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-03-21 Cont ID  
Sent By jwitmer Date 2022-03-21 Time 11:42 Rev Time 0.00
Received By jleahy Date 2022-03-21 Time 11:29 Sent To  
Notes
2022-03-15 09:13:37 
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-02-23 Cont ID  
Sent By jleahy Date 2022-02-23 Time 13:41 Rev Time 0.00
Received By jleahy Date 2022-02-23 Time 13:37 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-03-21 Cont ID  
Sent By jleahy Date 2022-03-21 Time 11:43 Rev Time 0.00
Received By jleahy Date 2022-03-21 Time 11:43 Sent To  
Notes
2022-03-21 11:43:34VOICE AND DATA JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-04-06 Cont ID  
Sent By   Date 2022-04-06 Time   Rev Time 0.00
Received By bdolan Date 2022-04-06 Time 13:57 Sent To  
Notes
2022-04-06 13:58:11ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE
 BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING
 COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED,
 REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU
 PRIOR TO ANY INSTALLATION.
  
 ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE
 COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR AND
 SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, ARE
 REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE
 FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-03-23 Cont ID  
Sent By cwalker Date 2022-03-23 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-03-23 10:17:30FIRE COMMENTS:
 ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE
 PERFORMED BY A FIRE ALARM CONTRACTOR. SEPARATE SHOP
 DRAWINGS AND PERMITS ARE REQUIRED FOR ANY FIRE ALARM
 WORK.
 ANY AND ALL WORK ON THE FIRE SPRINKLER SYSTEM SHALL BE
 PERFORMED BY A DIRE SPRINKLER CONTRACTOR. SEPARATE SHOP
 DRAWINGS AND PERMITS ARE REQUIRED FOR ANY FIRE
 SPRINKLER WORK.
 C. WALKER, SENIOR FIRE INSPECTOR
 561-804-4762
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-03-14 Cont ID  
Sent By   Date 2022-03-14 Time   Rev Time 0.00
Received By bdolan Date 2022-03-14 Time 12:18 Sent To  
Notes
2022-03-14 12:21:17ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE
 BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING
 COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED,
 REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU
 PRIOR TO ANY INSTALLATION.
  
 ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE
 COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR AND
 SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, ARE
 REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE
 FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-02-10 Cont ID  
Sent By   Date 2022-02-10 Time   Rev Time 0.00
Received By jcclark Date 2022-02-10 Time 09:48 Sent To  
Notes
2022-02-10 10:02:31ANY AND ALL WORK ON THE FIRE SPRINKLER AND/OR FIRE
 ALARM SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY CERTIFIED CONTRACTORS.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
 JOSEPH CLARK
 OFFICE OF THE FIRE MARSHAL
 561-804-4748
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-06 Cont ID  
Sent By jleahy Date 2022-04-06 Time 14:07 Rev Time 0.00
Received By jleahy Date 2022-04-04 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-30 Cont ID  
Sent By jleahy Date 2022-03-30 Time 14:59 Rev Time 0.00
Received By jleahy Date 2022-03-22 Time 07:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-21 Cont ID  
Sent By jleahy Date 2022-03-21 Time 11:45 Rev Time 0.00
Received By jleahy Date 2022-03-08 Time 16:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-02-23 Time   Rev Time 0.00
Received By cdecoeur Date 2022-02-09 Time 08:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-02-23 Cont ID  
Sent By medwards Date 2022-02-23 Time 13:38 Rev Time 0.00
Received By medwards Date 2022-02-23 Time 13:32 Sent To  
Notes
2022-02-23 13:41:04THERE ARE NO MECHANICAL DRAWINGS OR A MECHANICAL SCOPE
 OF WORK FOR THIS PROJECT.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-04-06 Cont ID  
Sent By ccole Date 2022-04-06 Time 08:19 Rev Time 0.00
Received By ccole Date 2022-04-06 Time 07:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-03-30 Cont ID  
Sent By ccole Date 2022-03-30 Time 13:24 Rev Time 0.00
Received By ccole Date 2022-03-30 Time 12:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-09 Time 12:20 Rev Time 0.00
Received By ccole Date 2022-03-09 Time 11:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-18 Cont ID  
Sent By ccole Date 2022-02-18 Time 12:12 Rev Time 0.00
Received By ccole Date 2022-02-18 Time 10:39 Sent To  
Notes
2022-02-18 12:13:441ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22010157
 2/18/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1.0 & P1.1: PLEASE CLARIFY WHAT THE 44-INCH
 MEASUREMENTS AT THE LAVATORIES ARE INDICATING-
 SEC.107.2.1 WPB.
  
 2) SHEETS 12.1, P1.0 & P1.1: SHOW THE CENTERLINES OF
 THE NEW LAVATORIES MEASURED FROM THE ADJACENT WALLS-
 SEC. 405.3.1 FBC P.
  
 3) SHEET 12.1: PROVIDE AN ELEVATION DETAIL OF THE NEW
 LAVATORIES SHOWING THE HEIGHTS OF THE SINK RIMS FROM
 THE FINISHED FLOORS, AND THE KNEE AND TOE CLEARANCES-
 SECS 606.2 & 606.3 FBC ACC.
  
 4) SHEET P2.0: TEMPERED WATER IS REQUIRED FOR THE
 LAVATORY SINKS- SEC. 419.5 FBC P. PLEASE PROVIDE A
 MANUFACTURER?S SPEC SHEET FOR THE WATTS #USG MIXING
 VALVE TO VERIFY THE DEVICE IS ASSE 1070 RATED TO
 DELIVER TEMPERED WATER.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-04-06 Cont ID  
Sent By ccole Date 2022-04-06 Time 07:56 Rev Time 0.00
Received By ccole Date 2022-04-06 Time 07:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-03-30 Cont ID  
Sent By ccole Date 2022-03-30 Time 13:30 Rev Time 0.00
Received By ccole Date 2022-03-30 Time 12:29 Sent To  
Notes
2022-03-30 13:59:07SIGNATURE REVIEW FBC- 2020
 PERMIT- 22010157
 3/30/22
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SUBMITTED PLAN SHEETS E0.0, E1.0, E1.1, E1.2,
 E2.0, E3.0, FP.1, P0.0, P1.0, P1.1, P2.0 APPEAR TO BE
 SCANNED COPIES OF ORIGINAL DIGITALLY SIGNED AND SEALED
 PLANS. PLANS PREPARED BY FL. LICENSED ENGINEERS THAT
 ARE TRANSMITTED ELECTRONICALLY SHALL BEAR VERIFIABLE
 DIGITAL SEALS AND SIGNATURES OF THE ENGINEER- FL.
 STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-03-15 Cont ID  
Sent By jwitmer Date 2022-03-15 Time 10:02 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-15 10:02:39THE ARCHITECTURAL SHEETS ARE DIGITALLY SIGNED.
 SHEETS NOT DIGITALLY SIGNED.
 E1.1, E1.2, E3.0, FP.1, P0.0, P1.O, P1.1 & P2.0 APPEAR
 TO BE PAPER PLANS UPLOADED.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) PLANS
 IN THE FILE FOLDER, SCANNED, FACSIMILE, DIGITALLY
 CREATED OR COPIED IMAGE OF THE LICENSEE?S SIGNATURE
 SHALL NOT BE USED ON ELECTRONIC/DIGITALLY SIGNED AND
 SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS.
  
  
  
 61G15-23.004 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD
 PARTY VERIFICATION.
 1) ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C., MAY BE SIGNED
 DIGITALLY AS PROVIDED HEREIN BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE. AS USED HEREIN, THE
 TERMS ?CERTIFICATION AUTHORITY,? AND ?DIGITAL
 SIGNATURE? SHALL HAVE THE MEANINGS ASCRIBED TO THEM IN
 SECTIONS 668.003(2) AND (3), F.S.
 (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL
 SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL
 HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION
 AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE
 IS:
 (A) UNIQUE TO THE PERSON USING IT;
 (B) CAPABLE OF VERIFICATION;
 (C) UNDER THE SOLE CONTROL OF THE PERSON USING IT; AND,
 (D) LINKED TO A DOCUMENT IN SUCH A MANNER THAT THE
 DIGITAL SIGNATURE AND CORRESPONDINGLY THE DOCUMENT IS
 INVALIDATED IF ANY DATA IN THE DOCUMENT IS CHANGED.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By jwitmer Date 2022-02-23 Time 14:41 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-02-23 14:41:19 
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) PLANS
 IN THE FILE FOLDER, SCANNED, FACSIMILE, DIGITALLY
 CREATED OR COPIED IMAGE OF THE LICENSEE?S SIGNATURE
 SHALL NOT BE USED ON ELECTRONIC/DIGITALLY SIGNED AND
 SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS.
  
  