Plan Review Details - Permit 22010151
Plan Review Stops For Permit 22010151
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-05-05 Cont ID  
Sent By rmcphers Date 2022-05-05 Time 09:05 Rev Time 0.00
Received By rmcphers Date 2022-05-05 Time 09:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-13 Cont ID  
Sent By rmcphers Date 2022-04-13 Time 13:05 Rev Time 0.00
Received By rmcphers Date 2022-04-13 Time 13:05 Sent To  
Notes
2022-04-13 13:14:55POOL
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) FENCE UNDER PERMIT 22031417 INPROGRESS (OK) - ALONG
 WITH A FENCE - - BARRIER FROM THE HOME NEEDS TO MEET
 R4501.17.1.9 -- (PLEASE WRITE ON THE BARRIER DRAWING
 THE TYPE OF BARRIER FROM THE HOME - WINDOW AND DOOR
 ALARMS OR POOL ALARM)
  
 R4501.17.1.9
 WHERE A WALL OF A DWELLING SERVES AS PART OF THE
 BARRIER, ONE OF THE FOLLOWING SHALL APPLY:
  
 1.ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM
 THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT
 ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND
 PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY
 DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES
 (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE
 ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF
 SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS
 BROKEN AT ANY OPENING.
  
 EXCEPTIONS:
  
 A.SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL
 HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE
 INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL.
  
 B.WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST
 STORY.
  
 C.SCREENED OR PROTECTED PASS-THROUGH KITCHEN WINDOWS 42
 INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH.
  
 2.ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO
 THE POOL MUST BE EQUIPPED WITH A SELF-CLOSING,
 SELF-LATCHING DEVICE WITH POSITIVE MECHANICAL
 LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372
 MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE
 AUTHORITY HAVING JURISDICTION.
  
 3.A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL,
 SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR
 UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM
 MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM
 STANDARD F2208, TITLED ?STANDARD SAFETY SPECIFICATION
 FOR RESIDENTIAL POOL ALARMS,? WHICH INCLUDES SURFACE
 MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS.
 FOR PURPOSES OF THIS PARAGRAPH, THE TERM ?SWIMMING POOL
 ALARM? DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM
 DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM
 ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS
 A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-03 Cont ID  
Sent By rmcphers Date 2022-03-03 Time 15:51 Rev Time 0.00
Received By rmcphers Date 2022-03-03 Time 15:45 Sent To  
Notes
2022-03-03 15:51:26POOL
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE TYPE AND LOCATION OF THE POOL
 BARRIER TO BE USED ON THE DRAWING TO COMPLY WITH FBC
 R4502.17.1

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-05-10 Cont ID  
Sent By fgiaquin Date 2022-05-10 Time 19:19 Rev Time 0.00
Received By fgiaquin Date 2022-05-10 Time 19:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-27 Cont ID  
Sent By fgiaquin Date 2022-01-27 Time 21:30 Rev Time 0.00
Received By fgiaquin Date 2022-01-27 Time 20:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-10 Cont ID  
Sent By fgiaquin Date 2022-05-10 Time 19:19 Rev Time 0.00
Received By fgiaquin Date 2022-04-29 Time 13:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-13 Cont ID  
Sent By rmcphers Date 2022-04-13 Time 13:18 Rev Time 0.00
Received By rmcphers Date 2022-04-04 Time 08:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-03 Cont ID  
Sent By rmcphers Date 2022-03-03 Time 15:54 Rev Time 0.00
Received By rmcphers Date 2022-01-06 Time 07:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-03 Cont ID  
Sent By lcrespo Date 2022-05-03 Time 09:50 Rev Time 0.00
Received By lcrespo Date 2022-05-03 Time 09:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-01-10 Cont ID  
Sent By lcrespo Date 2022-01-10 Time 13:55 Rev Time 0.00
Received By lcrespo Date 2022-01-10 Time 13:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-05-05 Cont ID  
Sent By rmcphers Date 2022-05-05 Time 09:05 Rev Time 0.00
Received By rmcphers Date 2022-05-05 Time 09:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-04-13 Cont ID  
Sent By rmcphers Date 2022-04-13 Time 13:15 Rev Time 0.00
Received By rmcphers Date 2022-04-13 Time 13:15 Sent To  
Notes
2022-04-13 13:18:14SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) ALL OF THE DRAWINGS PROVIDED DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-03 Cont ID  
Sent By rmcphers Date 2022-03-03 Time 15:54 Rev Time 0.00
Received By rmcphers Date 2022-03-03 Time 15:52 Sent To  
Notes
2022-03-03 15:54:12SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) ALL OF THE DRAWINGS PROVIDED DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By vbroglia Date 2022-05-09 Time 16:06 Rev Time 0.00
Received By vbroglia Date 2022-05-09 Time 16:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-01-24 Cont ID  
Sent By vbroglia Date 2022-01-24 Time 15:36 Rev Time 0.00
Received By vbroglia Date 2022-01-24 Time 15:36 Sent To  
Notes
***NONE***