Plan Review Details - Permit 22010130
Plan Review Stops For Permit 22010130 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-19 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-19 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-01-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-14 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-14 |
Time |
15:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-01-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-12 |
Time |
05:47 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-11 |
Time |
07:47 |
Sent To |
|
|
Notes |
2022-01-12 06:07:10 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | THE SUBMITTED ELEVATION CERTIFICATE (FINISHED | | CONSTRUCTION STAGE) NEEDS TO BE CORRECTED, SEE BELOW: | | | | 1.) SECTION A9 (A-D), NEEDS TO BE CORRECTED AS | | INFORMATION FOR THE EXISTING GARAGE FLOOD VENTS HAVE | | NOT BEEN INCLUDED. | | 2.) SECTION C, THE TIE-IN SURVEY DOES NOT SHOW THE | | LOCATION OF FLOOD VENTS. | | 3.) SECTION C2, THE BENCHMARK UTILIZED, AS NOTED IN | | SECTION D COMMENTS, IS INCOMPLETE. PLEASE REFERENCE THE | | SPECIFIC SOURCE FROM NETWORK REFERENCED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-01-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-14 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-13 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-01-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-12 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-05 |
Time |
05:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
3 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-01-19 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-01-19 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
F |
Date |
2022-01-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-19 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-19 |
Time |
13:02 |
Sent To |
|
|
Notes |
2022-01-19 13:04:27 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | NFIP REVIEW OF ELEVATION CERTIFICATE IS ONLY PENDING | | THE PEER REVIEW. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-01-18 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-01-18 |
Time |
14:10 |
Sent To |
|
|
Notes |
2022-01-18 14:20:38 | ELEVATION CERTIFICATE PEER REVIEW | | STATUS IS DENIED | | | | 1) THE INFORMATION ON THE ELEVATION CERTIFICATE DOES | | NOT MATCH THE PLANS FOR THE HOUSE. THE PHOTOS THAT WERE | | SUBMITTED WITH THE ELEVATION CERTIFICATE SHOW TWO | | ENGINEERED SMART VENTS IN EACH OF THE TWO OVERHEAD | | GARAGE DOORS LOCATED ON THE NORTH WALL FOR A TOTAL OF | | FOUR. THERE ARE TWO NON-ENGINEERED 36" X 24" FLOOD | | OPENINGS ON THE EAST GARAGE WALL. REVISE PLAN SHEETS | | A-1.0 AND A-6.0 TO MATCH WHAT HAS BEEN INSTALLED AND | | CORRECT THE GARAGE LOUVER CALCULATIONS ON SHEET A1.0 | | ACCORDINGLY. | | | | 2) SUBMIT THE DOCUMENTATION FROM THE MANUFACTURER FOR | | THE 36" X 24" GREENHECK AF J601X LOUVERS THAT SPECIFIES | | THE NET FREE OPENING AREA. | | | | 3) SUBMIT THE COMPLETE PRODUCT APPROVALS FOR THE GARAGE | | DOOR SMART VENTS INCLUDING THE EVALUATION REPORT AND | | INSTALLATION INSTRUCTIONS. | | | | 4) THE NOTES IN THE COMMENT SECTION OF THE ELEVATION | | CERTIFICATE FOR THE FLOOD VENTS SPECIFY NET AREA WHICH | | IS MISLEADING AS TO BEING THE NET FREE VENT AREA WHEN | | IT IS ACTUALLY THE GROSS AREA OF THE VENTS. PLEASE | | CORRECT TO STATE GROSS AREA. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-01-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-14 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-14 |
Time |
15:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-12 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-11 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
|