Plan Review Stops For Permit 22010129 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2022-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-04 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-04 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-02 |
Time |
11:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-23 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-23 |
Time |
11:13 |
Sent To |
|
|
Notes |
2022-03-23 11:28:49 | RESTAURANT BUILDOUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | 1) ALL PRODUCT APPROVALS PROVIDED NEED TO BE REVIEWED | | AND MARKED APPROVED BY THE ARCHITECT OR ENGINEER OF | | RECORD - FBC WPB 107.3.4 | | | | 2) PRODUCT APPROVAL PROVIDED FOR CASEMENT WINDOWS - | | PLEASE SHOW THE LOCATION AND LABEL AS SUCH ON THE | | DRAWINGS FOR THE CASEMENT WINDOWS. | | | | 3) PRODUCT APPROVAL PROVIDED FOR HORIZONTAL SLIDING | | WINDOWS - PLEASE SHOW THE LOCATION AND LABEL AS SUCH ON | | THE DRAWINGS FOR THE HORIZONTAL SLIDING WINDOWS. | | | | 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE BI FOLD DOORS/ WINDOWS SHOWN | | ON THE DRAWINGS. FBC 1609.1.2 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-04 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-04 |
Time |
09:55 |
Sent To |
|
|
Notes |
2022-02-04 10:14:06 | RESTAURANT BUILDOUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | 1) DRAWING 1.0A SHOWS ASCE 7-10 USED FOR WIND DESIGN - | | SHOULD BE ASCE 7-16 - PLEASE CORRECT FBC CHAPTER 35 | | | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR DOORS - ALL PRODUCT | | APPROVALS NEED TO BE REVIEWED AND MARKED APPROVED BY | | THE DESIGNER OF RECORD FBC WPB 107.3.4 | | | | 3) PLEASE SHOW THE RAMP HANDRAIL EXTENSIONS FBC A | | 505.10.1TOP AND BOTTOM EXTENSION AT RAMPS. | | RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE | | LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE TOP | | AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A | | WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE | | CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. | | | | 4) PLEASE SHOW THE RAMP EDGE PROTECTION PER FBC A 405.9 | | EDGE PROTECTION. | | EDGE PROTECTION COMPLYING WITH 405.9.1 OR 405.9.2 SHALL | | BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE | | OF RAMP LANDINGS. | | | | 5) ACCESSIBLE RESTROOMS - PLEASE SHOW ALL LOCATION | | DIMENSIONS FOR THE GRAB BARS, MIRROR, TOILET PAPER | | HOLDER, PAPER TOWEL REACH RANGES, ETC PER FBC | | ACCESSIBILITY | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-05-10 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-05-10 |
Time |
22:42 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-05-10 |
Time |
22:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-04-04 |
Time |
22:42 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-04-04 |
Time |
21:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-01-28 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-01-28 |
Time |
21:59 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-01-28 |
Time |
21:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-04-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-04-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-04-22 |
Time |
10:38 |
Sent To |
|
|
Notes |
2022-04-22 10:46:54 | FIRE PROVISO: | | | | 1) INSTALL EXIT SIGN AT BOTTOM OF STAIRWAY DOOR. | | | | | | 2) DOOR # 5 DEADBOLT - PER NFPA 101 | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | OF A KEY, | | A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION | | FROM THE EGRESS SIDE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-03-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-03-21 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-01-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-01-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-01-10 |
Time |
09:23 |
Sent To |
|
|
Notes |
2022-01-10 10:13:10 | FIRE PROVISO: | | | | 1) INSTALL EXIT SIGN AT BOTTOM OF STAIRWAY DOOR. | | | | | | 2) DOOR # 5 DEADBOLT - PER NFPA 101 | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | OF A KEY, | | A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION | | FROM THE EGRESS SIDE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2022-04-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-04-29 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-04-28 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-03-21 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-03-21 |
Time |
17:08 |
Sent To |
|
|
Notes |
2022-03-21 17:10:50 | 2ND REVIEW FBC-2020 FUEL GAS | | PERMIT- 22010129 | | 3/21/2022 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. REMAINING COMMENTS FROM | | THE 1ST REVIEW ARE LISTED BELOW. | | | | 1) FAILED. SHEET 3.0P GAS RISER: INCREASE THE 1-INCH | | PIPE SHOWN AT THE 33 FT. RUN TO 1-1/2-INCH BASED ON | | TABLE 402.4(2) FBC FG. CORRECTED SHEET 3.0P NOT | | UPLOADED. | | | | 2) FAILED. SHEET 3.0P GAS RISER: SHOW THE BRANCH PIPE | | SIZES FOR THE APPLIANCES ON THE COOKING LINE- TABLE | | 402.4(2) FBC FG. SHEET 3.1P SHOWS INDIVIDUAL COMBUSTION | | AIR INTAKE AND EXHAUST DUCTS. ALL OTHER PLANS INDICATE | | A CONCENTRIC VENT- WHICH IS IT? | | | | 4) FAILED. SHEET 3.0P: PROVIDE A VENTING DIAGRAM FOR | | THE TANKLESS WATER HEATER SHOWING THE TYPE AND SIZE OF | | CONCENTRIC, VENT RUN LENGTH FROM THE APPLIANCE TO THE | | TERMINATION ABOVE THE ROOF, CLEARANCE HEIGHT ABOVE THE | | ROOF, AND CLEARANCES TO AIR EXHAUST OUTLET AND AIR | | INTAKES ON THE ROOF- SECS. 503.2.3, 503.8 & 624.1. A) | | SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CONCENTRIC | | VENT DUCT- SECS. 503.4.1 & 624.1 FBC FG. PLEASE NOTE | | THE VENT DUCT SHALL BE LISTED AND LABELED PER SEC. | | 503.3.6: | | | | WHERE A VENTING SYSTEM PASSES THROUGH AN ABOVE-CEILING | | AIR-HANDLING SPACE OR OTHER NON-DUCTED PORTION OF AN | | AIR-HANDLING SYSTEM, THE VENTING SYSTEM SHALL CONFORM | | TO ONE OF THE FOLLOWING REQUIREMENTS: | | | | 1.THE VENTING SYSTEM SHALL BE A LISTED SPECIAL GAS | | VENT; OTHER VENTING SYSTEM SERVING A CATEGORY III OR | | CATEGORY IV APPLIANCE; OR OTHER POSITIVE PRESSURE VENT, | | WITH JOINTS SEALED IN ACCORDANCE WITH THE APPLIANCE OR | | VENT MANUFACTURER?S INSTRUCTIONS. | | 2.THE VENTING SYSTEM SHALL BE INSTALLED SUCH THAT | | FITTINGS AND JOINTS BETWEEN SECTIONS ARE NOT INSTALLED | | IN THE ABOVE-CEILING SPACE. | | 3.THE VENTING SYSTEM SHALL BE INSTALLED IN A CONDUIT OR | | ENCLOSURE WITH SEALED JOINTS SEPARATING THE INTERIOR OF | | THE CONDUIT OR ENCLOSURE FROM THE CEILING SPACE. VENT | | SPECS NOT SUBMITTED | | | | 6) FAILED. SHEET 3.0P: THE PLAN SHOWS A GAS-FIRED | | TANKLESS WATER HEATER ON THE EXTERIOR WALL. IS THIS | | HEATER IN USE OR TO BE REMOVED- SEC. 107.2.1 WPB. | | CORRECTED SHEET 3.0P NOT UPLOADED. | | | | 7) FAILED. SHEET 3.0P: PROVIDE A CONDENSATE DISPOSAL | | PLAN FOR THE NEW INTERIOR GAS-FIRED WATER HEATER- SECS. | | 307.2, 307.4, & 307.5 FBC FG. SHOW THE TYPE AND SIZE OF | | CONDENSATE PIPING, PIPING RUN, REQUIRED PAN, PAN DRAIN | | LINE AND DISPOSAL LOCATION. PLEASE NOTE A NEUTRALIZING | | DEVICE WILL BE REQUIRED PER SEC. 803.1 FBC P. CORRECTED | | SHEET 3.0P NOT UPLOADED. PLEASE NOTE THAT CONDESNATE | | SHALL NOT DRAIN INTO THE SANITARY SYSTEM- SEC. 90-126 | | WPB CODE OF ORDINANCES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCOLE@WPB. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-01-20 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-01-20 |
Time |
17:36 |
Sent To |
|
|
Notes |
2022-01-20 17:38:18 | 1ST REVIEW FBC-2020 FUEL GAS | | PERMIT- 22010129 | | 1/20/2022 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET 3.0P GAS RISER: INCREASE THE 1-INCH PIPE SHOWN | | AT THE 33 FT. RUN TO 1-1/2-INCH BASED ON TABLE 402.4(2) | | FBC FG. | | | | 2) SHEET 3.0P GAS RISER: SHOW THE BRANCH PIPE SIZES FOR | | THE APPLIANCES ON THE COOKING LINE- TABLE 402.4(2) FBC | | FG. | | | | 3) SHEET 3.0P: CORRECT THE COMBUSTION AIR CALCULATION | | TO INDICATE .35 X473 KBTUH- SEC. 304.9 FBC P. CLARIFY | | HOW THE 165 CFMS OF COMBUSTION AIR IS BEING PROVIDED | | MECHANICALLY. THE O/A CALCULATIONS ON SHEET 4.0M | | INDICATE A TOTAL OF 190 CFMS FOR THE OCCUPANTS- SEC. | | 304.9.3 FBC FG. | | | | 4) SHEET 3.0P: PROVIDE A VENTING DIAGRAM FOR THE | | TANKLESS WATER HEATER SHOWING THE TYPE AND SIZE OF | | CONCENTRIC, VENT RUN LENGTH FROM THE APPLIANCE TO THE | | TERMINATION ABOVE THE ROOF, CLEARANCE HEIGHT ABOVE THE | | ROOF, AND CLEARANCES TO AIR EXHAUST OUTLET AND AIR | | INTAKES ON THE ROOF- SECS. 503.2.3, 503.8 & 624.1. A) | | SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CONCENTRIC | | VENT DUCT- SECS. 503.4.1 & 624.1 FBC FG. PLEASE NOTE | | THE VENT DUCT SHALL BE LISTED AND LABELED PER SEC. | | 503.3.6: | | | | WHERE A VENTING SYSTEM PASSES THROUGH AN ABOVE-CEILING | | AIR-HANDLING SPACE OR OTHER NON-DUCTED PORTION OF AN | | AIR-HANDLING SYSTEM, THE VENTING SYSTEM SHALL CONFORM | | TO ONE OF THE FOLLOWING REQUIREMENTS: | | | | 1.THE VENTING SYSTEM SHALL BE A LISTED SPECIAL GAS | | VENT; OTHER VENTING SYSTEM SERVING A CATEGORY III OR | | CATEGORY IV APPLIANCE; OR OTHER POSITIVE PRESSURE VENT, | | WITH JOINTS SEALED IN ACCORDANCE WITH THE APPLIANCE OR | | VENT MANUFACTURER?S INSTRUCTIONS. | | 2.THE VENTING SYSTEM SHALL BE INSTALLED SUCH THAT | | FITTINGS AND JOINTS BETWEEN SECTIONS ARE NOT INSTALLED | | IN THE ABOVE-CEILING SPACE. | | 3.THE VENTING SYSTEM SHALL BE INSTALLED IN A CONDUIT OR | | ENCLOSURE WITH SEALED JOINTS SEPARATING THE INTERIOR OF | | THE CONDUIT OR ENCLOSURE FROM THE CEILING SPACE. | | | | 5) SHEET 3.0P: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | THE COOKING APPLIANCES- SEC. 623.1 FBC FG. | | | | 6) SHEET 3.0P: THE PLAN SHOWS A GAS-FIRED TANKLESS | | WATER HEATER ON THE EXTERIOR WALL. IS THIS HEATER IN | | USE OR TO BE REMOVED- SEC. 107.2.1 WPB. | | | | 7) SHEET 3.0P: PROVIDE A CONDENSATE DISPOSAL PLAN FOR | | THE NEW INTERIOR GAS-FIRED WATER HEATER- SECS. 307.2, | | 307.4, & 307.5 FBC FG. SHOW THE TYPE AND SIZE OF | | CONDENSATE PIPING, PIPING RUN, REQUIRED PAN, PAN DRAIN | | LINE AND DISPOSAL LOCATION. PLEASE NOTE A NEUTRALIZING | | DEVICE WILL BE REQUIRED PER SEC. 803.1 FBC P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | CCOLE@WPB. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-05-10 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-05-10 |
Time |
22:42 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-04-21 |
Time |
07:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-04-14 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-04-14 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-03-18 |
Time |
09:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-04 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-01-10 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-05-19 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-05-19 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-05-11 |
Time |
07:53 |
Sent To |
|
|
Notes |
2022-05-19 12:03:57 | 5/19/22 NO IMPACT FEES DUE, SEE UPLOADED EMAIL AO | 2022-05-11 07:53:21 | 5/11/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-04 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-04 |
Time |
10:21 |
Sent To |
|
|
Notes |
2022-02-04 10:22:44 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-04 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-04 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2022-03-29 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-03-29 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-03-29 |
Time |
13:20 |
Sent To |
|
|
Notes |
2022-03-29 13:21:27 | 2ND REVIEW FBC-2020 MECHANICAL | | PERMIT-22010129 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW THE OUTDOOR AIR REQUIRED FOR THE BAR. | | FMC TABLE 403.3.1.1 | | | | 2) THE WALK-IN COOLER WILL NOT BE REVIEWED AT THIS | | TIME. IT WILL REQUIRE A SEPARATE PERMIT AND PLAN | | REVIEW. FBC 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-01-13 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-01-13 |
Time |
12:06 |
Sent To |
|
|
Notes |
2022-01-13 12:06:48 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-22010129 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE LIFE SAFETY PLAN INDICATES A BREWERY BUT I DO | | NOT SEE ONE ON THE DRAWINGS. PLEASE LABEL EACH USE OF | | SPACE IN THIS CHANGE OF USE TENANT SPACE. FBC 107.2.1 | | | | 2) THE LIFE SAFETY SHEET INDICATES THE KITCHEN SQUARE | | FOOTAGE AS 1775, SHEET 4.0M INDICATES IN THE OUTDOOR | | AIR CALCULATIONS THAT THE KITCHEN SQUARE FOOTAGE IS | | ONLY 807. PLEASE BE CONSISTENT. FBC 107.2.1 | | | | 3) THE LIFE SAFETY SHEET INDICATES THE LOUNGE SQUARE | | FOOTAGE AS1583, SHEET 4.0M INDICATES IN THE OUTDOOR AIR | | CALCULATIONS THAT THE DINING ROOM SQUARE FOOTAGE IS | | 2695. PLEASE BE CONSISTENT. FBC 107.2.1 | | | | 4) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH | | USE OF SPACE IN THIS TENANT SPACE ACCORDING TO THE FBC | | M 403.3.1.1 AND TABLE 403.3.1.1 AND NOT THE OCCUPANT | | COUNT FROM THE ARCHITECT. | | | | 5) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS FOR EACH UNIT. FBC EC C403.2.1 | | | | 6) PLEASE SHOW HOW THE OUTDOOR AIR WILL BE DISTRIBUTED | | CONSISTENTLY IN THIS TENANT SPACE. FBC 107.2.1 | | | | 7) PLEASE IDENTIFY THE UNIT IN THE KITCHEN ON THE | | MECHANICAL DRAWING. FBC 107.2.1 | | | | 8) SHEET 2.2E INDICATES THERE IS A DISHWASHER, PLEASE | | SHOW THIS DISHWASHER ON THE MECHANICAL DRAWINGS. PLEASE | | ALSO PROVIDE DETAILS FOR THIS DISHWASHER. PLEASE SHOW | | HOW THIS DISHWASHER MEETS THE REQUIREMENTS OF FBC M | | 507.3 FOR HAVING A HOOD ABOVE THE DISHWASHER. | | | | 9) PLEASE PROVIDE THE CONDENSATE PIPE, SIZE AND | | TERMINATION LOCATION. FBC M 307 | | | | 10) PLEASE SHOW THAT THE EQUIPMENT ON THE ROOF WILL | | MEET THE GUARDS REQUIREMENT IN FBC M 304.11 | | | | 11) PLEASE SHOW THAT THE NEW EQUIPMENT ACCESS WILL MEET | | THE REQUIREMENTS FOR ACCESS INCLUDING THE 30 INCH HIGH | | REQUIREMENT FOR CLIMBING OVER OBSTRUCTIONS. FBC M 306.5 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-04-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-04-29 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-04-28 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-03-21 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-03-21 |
Time |
13:10 |
Sent To |
|
|
Notes |
2022-03-21 17:11:54 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 22010129 | | 3/21/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. REMAINING 1ST REVIEW | | COMMENTS LISTED BELOW. | | | | 1) FAILED. SHEETS C-1, 1.3A, 3.0P: PROVIDE PLUMBING | | FIXTURE CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC | | P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | PROVIDED NUMBER OF PLUMBING FIXTURES. PLEASE CLARIFY | | WHICH OCCUPANT LOAD IS CORRECT- (161 OCCUPANTS- SHEET | | C-1) OR (178 OCCUPANTS- SHEET 1.3A). PLEASE NOTE THAT | | DRINKING FOUNTAINS ARE REQUIRED FIXTURES FOR ASSEMBLY | | AND BUSINESS OCCUPANCIES. SHOW THE LOCATION OF THE | | REQUIRED DRINKING FOUNTAINS OR PLACE A NOTE TO INDICATE | | DRINKING WATER IN A CONTAINER FREE OF CHARGE WILL BE | | PROVIDED- SEC.- 410.4 FBC P. THE CORRECTED C-1 SHEET | | WAS NOT UPLOADED. | | | | 3) FAILED. SHEET 1.0A- MISSING ACCESSIBILITY DETAILS | | PER FBC ACC: | | K) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC. | | 605.2. NOT PROVIDED. | | L) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | ACCESSIBLE URINAL- SEC. 605.3. NOT PROVIDED. | | | | 4) FAILED. SHEET 1.0A: PROVIDE THE DEPTH MEASUREMENTS | | OF THE STANDARD RESTROOM STALLS- SEC. 405.3.1 FBC P. | | NOT PROVIDED. | | | | | | 5) FAILED. SHEET 3.0P: PROVIDE GREASE WASTE | | CALCULATIONS IN COMPLIANCE WITH SEC. 1003.3.5 FBC P. | | PLEASE ADD THE GREASE INTERCEPTOR TO THE LIST OF | | SEPARATE PERMITS ON SHEET C-1. NOTE: COMPLETE GREASE | | INTERCEPTOR PLANS, EQUIPMENT SPECIFICATIONS, | | CALCULATIONS AND DETAILS WILL BE REQUIRED UNDER THE | | SEPARATE PERMIT. CORRECTED SHEET 3.0P NOT UPLOADED. | | | | 12) FAILED. SHEETS 3.0P & 3.1P: PLEASE NOTE A SEPARATE | | PERMIT IS REQUIRED FOR THE POTABLE WATER SERVICE | | BACKFLOW PREVENTER- SEC. 105.1 & 107.2.1 WPB. PLEASE | | ADD THE DEVICE TO THE LIST OF SEPARATE PERMITS ON SHEET | | C-1. SHEET C-1 WITH MODIFED SEPARATE PERMIT LIST NOT | | UPLOADED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-01-20 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-01-20 |
Time |
11:52 |
Sent To |
|
|
Notes |
2022-01-20 17:43:36 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 22010129 | | 1/20/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS C-1, 1.3A, 3.0P: PROVIDE PLUMBING FIXTURE | | CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P. | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | PROVIDED NUMBER OF PLUMBING FIXTURES. PLEASE CLARIFY | | WHICH OCCUPANT LOAD IS CORRECT- (161 OCCUPANTS- SHEET | | C-1) OR (178 OCCUPANTS- SHEET 1.3A). PLEASE NOTE THAT | | DRINKING FOUNTAINS ARE REQUIRED FIXTURES FOR ASSEMBLY | | AND BUSINESS OCCUPANCIES. SHOW THE LOCATION OF THE | | REQUIRED DRINKING FOUNTAINS OR PLACE A NOTE TO INDICATE | | DRINKING WATER IN A CONTAINER FREE OF CHARGE WILL BE | | PROVIDED- SEC.- 410.4 FBC P. | | | | 2) SHEETS 1.0A, 1.3A, 3.0P, 3.1P: SHEET 1.3A INDICATES | | A 1390 SQ. FT. BREWERY. SHOW THE LOCATION OF THE | | BREWERY AND PROVIDE AN EQUIPMENT PLAN AND SCHEDULE- | | SEC. 107.2.1 WPB. | | | | 3) SHEET 1.0A- MISSING ACCESSIBILITY DETAILS PER FBC | | ACC: | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | WATER CLOSETS- SEC. 604.3. | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | LAVATORIES- SEC. 606.2. | | C) TURNING SPACE DIAMETERS- SEC. 304.3. | | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | WALLS- SEC. 604.2. | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | FLOORS- SEC. 604.4. | | F) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | FROM THE FINISHED FLOOR- SEC. 606.3. | | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | THE REFLECTIVE SURFACES- SEC. 603.3 | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | BARS FOR THE WATER CLOSETS- SECS. 604.5 & 609.4, | | FIGURES 604.5.1 & 604.5.2. | | I) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS ? SEC. | | 604.6. | | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | FIGURE 604.7. | | K) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC. | | 605.2 | | L) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | ACCESSIBLE URINAL- SEC. 605.3. | | M) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC. | | 606.2 | | | | 4) SHEET 1.0A: PROVIDE THE DEPTH MEASUREMENTS OF THE | | STANDARD RESTROOM STALLS- SEC. 405.3.1 FBC P. | | | | 5) SHEET 3.0P: PROVIDE GREASE WASTE CALCULATIONS IN | | COMPLIANCE WITH SEC. 1003.3.5 FBC P. PLEASE ADD THE | | GREASE INTERCEPTOR TO THE LIST OF SEPARATE PERMITS ON | | SHEET C-1. NOTE: COMPLETE GREASE INTERCEPTOR PLANS, | | EQUIPMENT SPECIFICATIONS, CALCULATIONS AND DETAILS WILL | | BE REQUIRED UNDER THE SEPARATE PERMIT. | | | | 6) SHEETS 3.0P & 3.1P: SHOW THE LOCATION OF THE GREASE | | INTERCEPTOR SAMPLING PORT AND INDICATE ACCESS WILL BE | | PROVIDED TO THE INTERCEPTOR COVERS AND CLEANOUTS- SECS. | | 708.1.7 & 708.1.10 FBC P. | | | | 7) SHEET 3.0P: THE LOCATION OF THE FLOOR SINK IN THE | | DETAIL DOES NOT MATCH THE LOCATION ON THE PLAN. THE | | PLAN SHOWS THE FLOOR SINK BETWEEN THE FOOD HANDLING | | (3-COMPARTMENT) SINK AND THE WARE WASHER- SEC. 802.1.1 | | AND 802.3 FBC P. PLEASE INCLUDE THE FLOOR SINKS IN THE | | PLUMBING FIXTURE SCHEDULE- SECS. 414.1 & 802.4 FBC P. | | | | 8) SHEETS 3.0P & 3.1P: PROVIDE VENTS FOR THE FLOOR | | SINKS AND FLOOR DRAINS IN THE KITCHEN AREA- SEC. 802.3 | | FBC P AND THE FLOOR DRAIN IN THE MEN'S RESTROOM- SECS. | | 910 & 911 FBC P. | | | | 9) SHEETS 3.0P & 3.1P: THE PLAN SHOWS 3/4-INCH SUPPLY | | LINES TO THE URINALS, AND THE RISER SHOWS 1-INCH- SEC. | | 107.2.1 WPB. PLEASE NOTE A COMPLETE REVIEW OF THE | | PLUMBING PLANS CANNOT BE COMPLETED WITH A PLUMBING | | FIXTURE SCHEDULE- TABLE 604.5 FBC P. | | | | 10) SHEETS 3.0P & 3.1P: SHOW LOCATIONS OF REQUIRED | | BACKFLOW PREVENTERS FOR SUPPLY LINES CONNECTING TO THE | | WARE WASHER, GLASS WASHER, AND ICE MAKERS- SEC. 608.3 | | FBC P. | | | | 11) SHEETS 3.0P & 3.1P: A RECIRCULATION PUMP IS SHOWN | | BUT THERE IS A NOTE INDICATING A RECIRCULATING WATER | | HEATER. WHICH RECIRCULATION SYSTEM WILL BE USED?- SEC. | | 607.1 FBC P. | | | | 12) SHEETS 3.0P & 3.1P: PLEASE NOTE A SEPARATE PERMIT | | IS REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW | | PREVENTER- SEC. 105.1 & 107.2.1 WPB. PLEASE ADD THE | | DEVICE TO THE LIST OF SEPARATE PERMITS ON SHEET C-1. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2022-04-10 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2022-04-10 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2022-04-10 |
Time |
12:13 |
Sent To |
|
|
Notes |
2022-04-10 12:14:08 | PRIVATE PROVIDER INSPECTIONS ONLY APPROVED | | | | RICHARD GATHRIGHT | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2022-03-18 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2022-03-18 |
Time |
12:46 |
Sent To |
|
|
Notes |
2022-03-18 12:51:18 | PRIVATE PROVIDER INSPECTIONS ONLY RREVIEW FAILED | | THE NTOB IS ONLY DOCUEMNT PROVIDED | | NEEC COI AND PP RESUMES PER 553.791 (4)(B) | | | | RICHARD GATHRIGHT | | ASSISTANT BUILDING OFFICIAL | | 561 805 6679 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-02 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-03-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-23 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-23 |
Time |
11:34 |
Sent To |
|
|
Notes |
2022-03-23 11:37:33 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | 1) THE TEMPORARY CONSTRUCTION SERVICE DRAWING SIGNED | | AND SEALED BY THOMAS J. TWOMEY P.E. DOES NOT SHOW AS | | DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | DIVISION AT THE CITY HALL. | | | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-04 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-04 |
Time |
10:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2022-05-04 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2022-05-04 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-04-13 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2022-04-13 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2022-04-13 |
Time |
13:31 |
Sent To |
|
|
Notes |
2022-04-13 13:35:10 | 1. SATISFIED - PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | 2. NOT SATISFIED- PLEASE PROVIDE DATA TO INDICATE THE | | TOTAL SQUARE FOOTAGE OF THE EXISTING BUILDING AND IF | | ANY ADDITIONAL SQUARE FOOTAGE IS PROPOSED (RELOCATE | | MAIN ENTRANCE) | | 3. NOT SATISFIED- CANOPY MINIMUMPROJECTION IS 8 FEET. | | PROPOSED CANOPY IS ONLY 4 FEET. | | 4. SATISIFED - PROVIDE DEMOLITION PLANS. | | 5. SATISFIED - GARBAGE LOCATION NOT PROVIDED ON SITE. - | | PLEASE PROVIDE INFORMATION REGARDING PROPOSED LOCATION | | FOR GARBAGE COLLECTION. | | 6. ANY NEW MECHANICAL EQUIPMENT LOCATED ON ROOF SHALL | | BE SCREEN. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-01-27 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2022-01-27 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2022-01-27 |
Time |
16:51 |
Sent To |
|
|
Notes |
2022-01-27 16:56:11 | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | 2. PLEASE PROVIDE DATA TO INDICATE THE TOTAL SQUARE | | FOOTAGE OF THE EXISTING BUILDING AND IF ANY ADDITIONAL | | SQUARE FOOTAGE IS PROPOSED (RELOCATE MAIN ENTRANCE) | | 3. PROVIDE INFORMATION REGARDING THE PROPOSED CANOPY | | INCLUDING HEIGHT, PROJECTION. | | 4. PROVIDE DEMOLITION PLANS. | | 5. PLEASE PROVIDE INFORMATION REGARDING PROPOSED | | LOCATION FOR GARBAGE COLLECTION. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439 |
|
|