Plan Review Details - Permit 22010046
Plan Review Stops For Permit 22010046
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-03-21 Cont ID  
Sent By pvalenti Date 2022-03-21 Time 16:10 Rev Time 0.00
Received By pvalenti Date 2022-03-21 Time 16:10 Sent To  
Notes
2022-03-21 16:12:35PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 PRIOR TO ROOF WORK A ROOFING SUB-PERMIT IS REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-10 Cont ID  
Sent By pvalenti Date 2022-03-10 Time 08:34 Rev Time 0.00
Received By pvalenti Date 2022-03-10 Time 08:02 Sent To  
Notes
2022-03-10 08:56:50PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIOEW DENIED:
  
 1.) FBC B 107.2.1, THE INDIVIDUAL RESPONSIBLE FOR THE
 ARCHITECTURAL "A" SHEETS (R&R CONSTRUCTION) NEEDS TO
 SIGN THESE PLAN SHEETS.
 2.) FBC B 107.2.1, A ROOFING SUB-PERMIT IS REQUIRED FOR
 THE ROOFING WORK.
 3.) AN ELECTRICAL SUB-PERMIT IS REQUIRED FOR ELECTRICAL
 WORK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-04-06 Cont ID  
Sent By mpeterso Date 2022-04-06 Time 11:44 Rev Time 0.00
Received By mpeterso Date 2022-04-06 Time 11:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-10 Cont ID  
Sent By jleahy Date 2022-03-10 Time 10:04 Rev Time 0.00
Received By jleahy Date 2022-03-10 Time 10:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-06 Cont ID  
Sent By mpeterso Date 2022-04-06 Time 11:44 Rev Time 0.00
Received By mpeterso Date 2022-03-20 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-10 Cont ID  
Sent By pvalenti Date 2022-03-10 Time 08:57 Rev Time 0.00
Received By pvalenti Date 2022-01-11 Time 08:22 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-21 Cont ID  
Sent By pvalenti Date 2022-03-21 Time 16:10 Rev Time 0.00
Received By pvalenti Date 2022-03-21 Time 16:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-10 Cont ID  
Sent By pvalenti Date 2022-03-10 Time 08:26 Rev Time 0.00
Received By pvalenti Date 2022-03-10 Time 08:02 Sent To  
Notes
2022-03-10 08:28:57SIGNATURE REVIEW DENIED:
  
 THE SUBMITTED PLANS SIGNED/SEALED BY (GARY MCDOUGAL
 P.E.) ARE NOT 3RD PARTY VERIFIABLE.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-03-25 Cont ID  
Sent By vbroglia Date 2022-03-25 Time 15:18 Rev Time 0.00
Received By vbroglia Date 2022-03-25 Time 15:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-01-18 Cont ID  
Sent By vbroglia Date 2022-01-18 Time 14:59 Rev Time 0.00
Received By vbroglia Date 2022-01-18 Time 14:59 Sent To  
Notes
2022-01-18 15:15:431/18/22 FAILED- PER CODE ACCESSORY STRUCTURES COVERED
 WITH A SOLID ROOF SHALL BE LOCATED NO CLOSER THAN SIX
 FEET TO THE PRINCIPAL STRUCTURE. ACCESSORY STRUCTURES
 LESS THAN SIX FEET FROM THE PRIMARY STRUCTURE MUST MEET
 THE PRIMARY STRUCTURE SETBACKS.
  
 PER CODE IN SF7 ZONING SIDE SETBACKS NEED TO BE 5 FEET
 MIN, AND HAVE A TOTAL OF 15 FEET WHEN ADDING BOTH SIDES
 UP.
  
 PLEASE ONLY SUBMIT THE PROPOSED SHED ON THE SITE PLAN
 FOR THIS PERMIT
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  