Plan Review Details - Permit 21121220
Plan Review Stops For Permit 21121220
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-06-15 Cont ID  
Sent By lmarchan Date 2022-06-15 Time 10:13 Rev Time 0.00
Received By lmarchan Date 2022-06-15 Time 10:13 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-04-04 Cont ID  
Sent By rmcdouga Date 2022-04-04 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2022-04-04 Time 16:42 Sent To  
Notes
2022-04-04 16:43:10PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-02-14 Cont ID  
Sent By rmcdouga Date 2022-02-14 Time 11:25 Rev Time 0.00
Received By rmcdouga Date 2022-02-14 Time 11:25 Sent To  
Notes
2022-04-04 16:43:29PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-12 Cont ID  
Sent By rmcdouga Date 2022-07-12 Time 13:34 Rev Time 0.00
Received By rmcdouga Date 2022-07-12 Time 13:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-06-22 Cont ID  
Sent By rmcdouga Date 2022-06-22 Time 14:36 Rev Time 0.00
Received By rmcdouga Date 2022-06-22 Time 14:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-04 Cont ID  
Sent By rmcdouga Date 2022-04-04 Time 18:41 Rev Time 0.00
Received By rmcdouga Date 2022-04-04 Time 17:02 Sent To  
Notes
2022-04-04 18:41:32PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NOT RESOLVED. [ SHEET A-3 THE INTERIOR ELEVATIONS
 WAS NOT UPLOADED. PLAN SHEET A-4, THE ACCESSIBILITY
 DETAILS, IS UPLOADED UNDER PAGE 007 A-3. SHEET ID-1 IS
 INCORRECTLY UPLOADED UNDER PAGE 008 A-4. SHEET ID-1 WAS
 UPLOADED TWICE. PAGES 008 AND 009 BOTH HAVE PLAN SHEET
 ID-1 UPLOADED. ] THE KITCHEN ELEVATIONS 1,2,3 & 4 THAT
 ARE TAGGED ON THE FLOOR PLAN ON SHEET A1 AS BEING ON
 SHEET A2 ARE MISSING. THE COUNTER TOP HEIGHTS AND REACH
 RANGES ARE REQUIRED TO COMPLY WITH THE 2020 FBC
 ACCESSIBILTY. FBC 107.2.1
  
 2) NEW COMMENT. ON THE LIFE SAFETY PLAN PAGE 003 LS-1
 THE KITCHEN AREA IS SHOWN AS LARGER THAN THE ACTUAL
 KITCHEN AREA. IT APPEARS THIS IS BEING DONE TO REDUCE
 THE SIZE OF THE DINING/ASSEMBLY AREA. THE KITCHEN AREA
 NEEDS TO BE LIMITED TO THE AREA WHERE THE FOOD
 PREPARATION AND OTHER KITCHEN ACTIVITIES WILL ACTUALLY
 OCCUR. ALSO NOTE THAT FBC 1016.2 (5) PROHIBITS EXIT
 ACCESS THROUGH KITCHENS.
  
 3) THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING:
 A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1
 B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1
 C) EXIT SEPARATION DISTANCE FBC 1015.2.1
 D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3
 E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3
 F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC
 1008.1.1
 G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND
 MEANS OF EGRESS FACTOR FBC1005.3.2
 H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5
  
 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. NOTE:
 ADDITIONAL COMMENTS MAY RESULT WHEN THE MISSING
 INFORMATION IS PROVIDED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-02-14 Cont ID  
Sent By rmcdouga Date 2022-02-14 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2022-02-14 Time 15:56 Sent To  
Notes
2022-02-14 16:42:09PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE KITCHEN ELEVATIONS 1,2,3 & 4 THAT ARE TAGGED ON
 THE FLOOR PLAN ON SHEET A1 AS BEING ON SHEET A2 ARE
 MISSING. THE COUNTER TOP HEIGHTS AND REACH RANGES ARE
 REQUIRED TO COMPLY WITH THE 2020 FBC ACCESSIBILTY. FBC
 107.2.1
  
 NOTE: ADDITIONAL COMMENTS MAY RESULT WHEN THE MISSING
 INFORMATION IS PROVIDED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-07-21 Cont ID  
Sent By mpeterso Date 2022-07-21 Time 08:01 Rev Time 0.00
Received By mpeterso Date 2022-07-21 Time 08:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 12:53 Rev Time 0.00
Received By mpeterso Date 2022-06-03 Time 12:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-02-08 Cont ID  
Sent By mpeterso Date 2022-02-08 Time 11:52 Rev Time 0.00
Received By mpeterso Date 2022-02-08 Time 11:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-05-23 Cont ID  
Sent By cwalker Date 2022-05-23 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-03-14 Cont ID  
Sent By cwalker Date 2022-03-14 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-01-24 Cont ID  
Sent By cwalker Date 2022-01-24 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-01-24 13:41:45FIRE PROVISO NOTES:(FAIL)
 1. COOKING EQUIPMENT USED IN PROCESSES PRODUCING SMOKE
 OR GREASE LADEN VAPORS SHALL BE EQUIPPED WITH AN
 EXHAUST SYSTEM THAT COMPLIES WITH ALL THE EQUIPMENT AND
 PERFORMANCE REQUIREMENTS OF THIS STANDARD. NFPA 96,
 4.1.1
 COOKING EQUIPMENT THAT PRODUCES GREASE LADEN VAPORS AND
 THAT MIGHT BE AA SOURCE OF IGNITION OF GREASE IN THE
 HOOD, GREASE REMOVAL DEVICE, OR DUCT SHALL BE PROTECTED
 BY FIRE-EXTINGUISHING EQUIPMENT. NFPA 96, 10.1.2
 FOR CLARIFICATION AND THE OFFICIAL RECORD, PROVIDE A
 DETAILED DESCRIPTION OF THE USE THE DEMONSTRATION
 KITCHEN.
  
 2. ALL FIRE SPRINKLER AND/OR FIRE ALARM WORK SHALL BE
 PERFORMED UNDER SEPARATE PERMITS AND SHOP DRAWINGS. THE
 WORK IS TO BE PERFORMED BY QUALIFIED, PROPERLY LICENSED
 CONTRACTORS.
  
 3. ANY IMPAIRMENTS TO THE FIRE/LIFE SAFETY SYSTEMS IN
 EXCESS OF 4 HOURS DURATION SHALL REQUIRE A FIRE WATCH
 TO BE IMPLEMENTED.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-07-21 Cont ID  
Sent By mpeterso Date 2022-07-21 Time 08:02 Rev Time 0.00
Received By mpeterso Date 2022-07-05 Time 06:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-22 Cont ID  
Sent By rmcdouga Date 2022-06-22 Time 14:37 Rev Time 0.00
Received By rmcdouga Date 2022-05-21 Time 09:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-04 Cont ID  
Sent By rmcdouga Date 2022-04-04 Time 18:41 Rev Time 0.00
Received By rmcdouga Date 2022-03-11 Time 08:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-14 Cont ID  
Sent By rmcdouga Date 2022-02-14 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2022-01-06 Time 09:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-05-31 Cont ID  
Sent By medwards Date 2022-05-31 Time 06:55 Rev Time 0.00
Received By medwards Date 2022-05-31 Time 06:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-04-01 Cont ID  
Sent By medwards Date 2022-04-01 Time 11:51 Rev Time 0.00
Received By medwards Date 2022-04-01 Time 11:51 Sent To  
Notes
2022-04-01 11:54:12PLEASE SHOW THAT THE NEW DEMONSTRATION KITCHEN COOKING
 AREA MEETS FMC 507.1.2.
  
 507.1.2 DOMESTIC COOKING APPLIANCES USED FOR COMMERCIAL
 PURPOSES. DOMESTIC COOKING APPLIANCES UTILIZED FOR
 COMMERCIAL PURPOSES SHALL BE PROVIDED WITH TYPE I OR
 TYPE II HOODS AS REQUIRED FOR THE TYPE OF APPLIANCES
 AND
 PROCESSES IN ACCORDANCE WITH SECTIONS 507.2 AND 507.3.
 DOMESTIC COOKING APPLIANCES UTILIZED FOR DOMESTIC
 PURPOSES
 SHALL COMPLY WITH SECTION 505.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-02-03 Cont ID  
Sent By medwards Date 2022-02-03 Time 08:12 Rev Time 0.00
Received By medwards Date 2022-02-03 Time 08:12 Sent To  
Notes
2022-02-03 08:13:091ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21121220
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE INFORMATION ON THE COOKTOP AND THE
 HOOD ABOVE. PLEASE PROVIDE INFORMATION ON THE OVEN.
 PLEASE SHOW HOW THIS INSTALLATION WILL MEET FBC M507
 FOR COMMERCIAL KITCHEN HOODS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-05-26 Cont ID  
Sent By jesmith Date 2022-05-26 Time 14:26 Rev Time 0.00
Received By jesmith Date 2022-05-24 Time 12:16 Sent To  
Notes
2022-05-26 14:26:2722030798 4500 S DIXIE HWY
  
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-03-29 Cont ID  
Sent By jesmith Date 2022-03-29 Time 16:32 Rev Time 0.00
Received By jesmith Date 2022-03-29 Time 16:32 Sent To  
Notes
2022-03-29 16:32:50CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21121220 4920 LORING DR
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
  
 1.NEW COMMENT: DUE TO A CHANGE IN PROCESS, THE BACKFLOW
 PERMIT AND GREASE INTERCEPTOR PERMITS ARE REQUIRED TO
 BE SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT
 (AS APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD"
 (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR
 SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 2.NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE DETAIL FOR
 SINK SHOWING HEIGHT, KNEE AND TOE SPACE. FRONT APPROACH
 FOR SINK IS SHOWN ON A1. COMPLY WITH FBC ACC 606.3,
 306.2 AND 306.3.
  
 3. SECOND REQUEST: MATERIAL SPEC PER WPB FBC 107.2.1,
 PROVIDE PIPING MATERIAL SPEC FOR EACH SYSTEM TO INCLUDE
 PIPE, VALVES, FITTINGS AND JOINTS. COMPLY WITH FBC PL
 CHAPTERS 3, 6, 7, 9 AND 11.
 PROVIDE SPECIFICATION 22 10 00 AS NOTED IN RESPONSE.
  
 4.NEW COMMENT: A VENT IS REQUIRED FOR THE EXISTING
 FLOOR DRAIN PER FBC PL 901.2.1.
  
 5.NEW COMMENT: PLEASE NOTE THAT PER FBC PL 301.7 AND
 303.2, THE INSTALLATION OF THE SCHIER GB-75 GREASE
 INTERCEPTOR SHALL CONFORM TO A MINIMUM OF THE
 MANUFACTURER?S RECOMMENDATIONS. IN ACCORDANCE WITH THE
 GB-75 INSTALLATION MANUAL, A TWO-WAY CLEANOUT IS
 REQUIRED ON THE INLET AND OUTLET SIDE OF THE GREASE
 INTERCEPTOR.
  
 6. NEW COMMENT: PER WPB FBC 107.2.1, TO SHOW COMPLIANCE
 WITH FBC PL 409.4, PROVIDE A NOTE ON P-4/DISHWASHING
 CONNECTION STATING "THE WASTE CONNECTION OF A
 RESIDENTIAL DISHWASHER SHALL CONNECT DIRECTLY TO A WYE
 BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK,
 DIRECTLY TO THE DISHWASHER CONNECTION OF A FOOD WASTE
 DISPOSER, OR THROUGH AN AIR BREAK TO A STANDPIPE. THE
 WASTE LINE OF A RESIDENTIAL DISHWASHER SHALL RISE AND
 BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM
 OR COUNTER TOP."
  
 7.SECOND REQUEST: A WATER HAMMER ARRESTOR IS REQUIRED
 ON THE HOT WATER TO THE DISHWASHER PER FBC PL 604.9.
 PER WPB FBC 107.2.1, PROVIDE A WATER HAMMER ARRESTOR
 FOR THE HOT WATER TO THE DISHWASHER. THIS MAY BE
 ACCOMPLISHED BY PROVIDING A NOTE ON P-4/DISHWASHING
 CONNECTION.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-01 Cont ID  
Sent By jesmith Date 2022-02-01 Time 12:15 Rev Time 0.00
Received By jesmith Date 2022-02-01 Time 09:16 Sent To  
Notes
2022-02-01 12:13:59CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21121220 4920 LORING DR
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1. PER FBC ACC 212.3, WHERE SINKS ARE PROVIDED, AT
 LEAST 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE
 PROVIDED IN EACH ACCESSIBLE ROOM OR SPACE SHALL COMPLY
 WITH 606.
  
 2. MATERIAL SPEC PER WPB FBC 107.2.1, PROVIDE PIPING
 MATERIAL SPEC FOR EACH SYSTEM TO INCLUDE PIPE, VALVES,
 FITTINGS AND JOINTS. COMPLY WITH FBC PL CHAPTERS 3, 6,
 7, 9 AND 11.
  
 3. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH
 A NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN
 ACCORDANCE WITH FBC PL TABLE 308.5."
  
 4. PER WPB FBC 107.2.1, PROVIDE A SLAB REPAIR DETAIL ON
 THE PLANS. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM
 THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED. SHOW
 SIZE, LENGTH, SPACING (ON CENTER), MINIMUM EMBEDMENT
 AND ANCHORING/ADHESIVE MATERIAL FOR DOWELS. THE REPAIR
 SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AS
 WELL AS THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR FINAL INSPECTION.
  
 5. PER WPB FBC 107.2.1 AND 107.3.5.1.3 , PROVIDE A
 SCHEDULE, CALCULATIONS AND DETAIL OF THE GREASE
 INTERCEPTOR SHOWING COMPLIANCE WITH FBC PL 1003.3.5 AND
 1003.3.5.1.
  
 6. PER WPB FBC 107.2.1 AND 107.3.5.1.3, PROVIDE THE
 FOLLOWING:
 ?A) A DETAIL FOR THE SEPARATE DISCHARGES OF THE GREASY
 WASTE AND THE DISPOSAL WASTE FROM THE NEW SINK TO
 SANITARY; INCLUDE THE DISCHARGE FROM THE DISHWASHER.
 ?B) CLEARLY SHOW ON THE SANITARY RISER DIAGRAM TWO
 SEPARATE TRAPPED AND VENTED FIXTURE DRAINS FOR THE
 DISPOSAL AND FOR SINK/DISHWASHER.
 ?C) PROVIDE SIZING FOR ALL NEW DRAINS ON THE SANITARY
 RISER DIAGRAM.
  
 7. P-2, DEMO NOTE 5 INDICATES AN EXISTING FLOOR DRAIN
 IS TO REMAIN. PER WPB FBC 107.2.1, INDICATE HOW THE
 EXISTING TRAP SEAL PROTECTION IS TO REMAIN. IF
 CONDITIONS DO NOT ALLOW THE EXISTING PROTECTION TO
 REMAIN INTACT, PROVIDE NEW DETAIL/SPECIFICATION FOR
 TRAP SEAL PROTECTION COMPLYING WITH ONE OF THE
 FOLLOWING: FBC 1002.4.1.1, 1002.4.1.2, 1002.4.1.3 OR
 1002.4.1.4.
  
 8. PER WPB FBC 107.2.1 AND 107.3.5.1.3, CLEARLY SHOW ON
 THE WATER RISER DIAGRAM THE FOLLOWING:
 ?A) A WATER HAMMER ARRESTOR FOR THE HOT WATER TO THE
 DISHWASHER SHOWING COMPLIANCE WITH FBC PL 604.9.
 ?B) IDENTIFY THE DISHWASHER CONNECTION.
 ?C) PROVIDE SIZING FOR ALL NEW BRANCHES.
  
 9. PER WPB FBC 107.2.1 AND 107.3.5.1.3, PROVIDE
 CALCULATIONS FOR SIZING OF WATER DISTRIBUTION AND
 SANITARY DRAINS.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-07-12 Cont ID  
Sent By rmcdouga Date 2022-07-12 Time 13:53 Rev Time 0.00
Received By rmcdouga Date 2022-07-12 Time 13:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 13:02 Rev Time 0.00
Received By mpeterso Date 2022-06-03 Time 12:59 Sent To  
Notes
2022-06-03 13:04:57SIGNATURE REVIEW FAILED
 !) SHEETS A1,A2 AND A3 DO NOT APPEAR TO HAVE THE
 REQUIRED SEAL AND SIGNATURE.
  
 PLEASE FOLLOW THE DIRECTIONS OUTLINED BELOW TO CORRECT
 THIS ISSUE.FS471/FS481 DOCUMENTS PREPARED BY AN
 ARCHITECT OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD
 ARE TO BE SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY
 SEALED AND SIGNED.
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING
 DEPARTMENT.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
 PLEASE EMAIL [email protected] AND CC TO
 [email protected] WITH ANY QUESTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
2022-05-31 06:56:15DIGIAL SIGNATURE FOR MECHANICAL APPROVED ME
2022-05-24 12:17:07SIGNATURES FOR PLUMBING ARE VALID. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-04-04 Cont ID  
Sent By rmcdouga Date 2022-04-04 Time 16:41 Rev Time 0.00
Received By rmcdouga Date 2022-04-04 Time 16:41 Sent To  
Notes
2022-03-29 16:34:00PLUMBING SIGNATURES VALID JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-02-14 Cont ID  
Sent By rmcdouga Date 2022-02-14 Time 14:24 Rev Time 0.00
Received By rmcdouga Date 2022-02-14 Time 14:24 Sent To  
Notes
***NONE***