Plan Review Stops For Permit 21121220 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2022-06-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-06-15 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-06-15 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-04 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-04-04 |
Time |
16:42 |
Sent To |
|
|
Notes |
2022-04-04 16:43:10 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-14 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-14 |
Time |
11:25 |
Sent To |
|
|
Notes |
2022-04-04 16:43:29 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-07-12 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-07-12 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-06-22 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-06-22 |
Time |
14:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-04 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-04-04 |
Time |
17:02 |
Sent To |
|
|
Notes |
2022-04-04 18:41:32 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NOT RESOLVED. [ SHEET A-3 THE INTERIOR ELEVATIONS | | WAS NOT UPLOADED. PLAN SHEET A-4, THE ACCESSIBILITY | | DETAILS, IS UPLOADED UNDER PAGE 007 A-3. SHEET ID-1 IS | | INCORRECTLY UPLOADED UNDER PAGE 008 A-4. SHEET ID-1 WAS | | UPLOADED TWICE. PAGES 008 AND 009 BOTH HAVE PLAN SHEET | | ID-1 UPLOADED. ] THE KITCHEN ELEVATIONS 1,2,3 & 4 THAT | | ARE TAGGED ON THE FLOOR PLAN ON SHEET A1 AS BEING ON | | SHEET A2 ARE MISSING. THE COUNTER TOP HEIGHTS AND REACH | | RANGES ARE REQUIRED TO COMPLY WITH THE 2020 FBC | | ACCESSIBILTY. FBC 107.2.1 | | | | 2) NEW COMMENT. ON THE LIFE SAFETY PLAN PAGE 003 LS-1 | | THE KITCHEN AREA IS SHOWN AS LARGER THAN THE ACTUAL | | KITCHEN AREA. IT APPEARS THIS IS BEING DONE TO REDUCE | | THE SIZE OF THE DINING/ASSEMBLY AREA. THE KITCHEN AREA | | NEEDS TO BE LIMITED TO THE AREA WHERE THE FOOD | | PREPARATION AND OTHER KITCHEN ACTIVITIES WILL ACTUALLY | | OCCUR. ALSO NOTE THAT FBC 1016.2 (5) PROHIBITS EXIT | | ACCESS THROUGH KITCHENS. | | | | 3) THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING: | | A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1 | | B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1 | | C) EXIT SEPARATION DISTANCE FBC 1015.2.1 | | D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3 | | E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3 | | F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC | | 1008.1.1 | | G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND | | MEANS OF EGRESS FACTOR FBC1005.3.2 | | H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5 | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. NOTE: | | ADDITIONAL COMMENTS MAY RESULT WHEN THE MISSING | | INFORMATION IS PROVIDED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-14 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-14 |
Time |
15:56 |
Sent To |
|
|
Notes |
2022-02-14 16:42:09 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE KITCHEN ELEVATIONS 1,2,3 & 4 THAT ARE TAGGED ON | | THE FLOOR PLAN ON SHEET A1 AS BEING ON SHEET A2 ARE | | MISSING. THE COUNTER TOP HEIGHTS AND REACH RANGES ARE | | REQUIRED TO COMPLY WITH THE 2020 FBC ACCESSIBILTY. FBC | | 107.2.1 | | | | NOTE: ADDITIONAL COMMENTS MAY RESULT WHEN THE MISSING | | INFORMATION IS PROVIDED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-07-21 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-07-21 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-07-21 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-03 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-03 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-02-08 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-02-08 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-02-08 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-05-23 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-03-14 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-03-14 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-01-24 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-01-24 13:41:45 | FIRE PROVISO NOTES:(FAIL) | | 1. COOKING EQUIPMENT USED IN PROCESSES PRODUCING SMOKE | | OR GREASE LADEN VAPORS SHALL BE EQUIPPED WITH AN | | EXHAUST SYSTEM THAT COMPLIES WITH ALL THE EQUIPMENT AND | | PERFORMANCE REQUIREMENTS OF THIS STANDARD. NFPA 96, | | 4.1.1 | | COOKING EQUIPMENT THAT PRODUCES GREASE LADEN VAPORS AND | | THAT MIGHT BE AA SOURCE OF IGNITION OF GREASE IN THE | | HOOD, GREASE REMOVAL DEVICE, OR DUCT SHALL BE PROTECTED | | BY FIRE-EXTINGUISHING EQUIPMENT. NFPA 96, 10.1.2 | | FOR CLARIFICATION AND THE OFFICIAL RECORD, PROVIDE A | | DETAILED DESCRIPTION OF THE USE THE DEMONSTRATION | | KITCHEN. | | | | 2. ALL FIRE SPRINKLER AND/OR FIRE ALARM WORK SHALL BE | | PERFORMED UNDER SEPARATE PERMITS AND SHOP DRAWINGS. THE | | WORK IS TO BE PERFORMED BY QUALIFIED, PROPERLY LICENSED | | CONTRACTORS. | | | | 3. ANY IMPAIRMENTS TO THE FIRE/LIFE SAFETY SYSTEMS IN | | EXCESS OF 4 HOURS DURATION SHALL REQUIRE A FIRE WATCH | | TO BE IMPLEMENTED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-21 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-07-21 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-07-05 |
Time |
06:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-06-22 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-05-21 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-04 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-03-11 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-14 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-01-06 |
Time |
09:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-31 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-31 |
Time |
06:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2022-04-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-04-01 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-04-01 |
Time |
11:51 |
Sent To |
|
|
Notes |
2022-04-01 11:54:12 | PLEASE SHOW THAT THE NEW DEMONSTRATION KITCHEN COOKING | | AREA MEETS FMC 507.1.2. | | | | 507.1.2 DOMESTIC COOKING APPLIANCES USED FOR COMMERCIAL | | PURPOSES. DOMESTIC COOKING APPLIANCES UTILIZED FOR | | COMMERCIAL PURPOSES SHALL BE PROVIDED WITH TYPE I OR | | TYPE II HOODS AS REQUIRED FOR THE TYPE OF APPLIANCES | | AND | | PROCESSES IN ACCORDANCE WITH SECTIONS 507.2 AND 507.3. | | DOMESTIC COOKING APPLIANCES UTILIZED FOR DOMESTIC | | PURPOSES | | SHALL COMPLY WITH SECTION 505. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-02-03 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-02-03 |
Time |
08:12 |
Sent To |
|
|
Notes |
2022-02-03 08:13:09 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21121220 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE INFORMATION ON THE COOKTOP AND THE | | HOOD ABOVE. PLEASE PROVIDE INFORMATION ON THE OVEN. | | PLEASE SHOW HOW THIS INSTALLATION WILL MEET FBC M507 | | FOR COMMERCIAL KITCHEN HOODS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-05-26 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-05-24 |
Time |
12:16 |
Sent To |
|
|
Notes |
2022-05-26 14:26:27 | 22030798 4500 S DIXIE HWY | | | | | | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-03-29 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-03-29 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-03-29 |
Time |
16:32 |
Sent To |
|
|
Notes |
2022-03-29 16:32:50 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 21121220 4920 LORING DR | | | | 2ND REVIEW | | PLUMBING COMMENTS: DENIED | | | | 1.NEW COMMENT: DUE TO A CHANGE IN PROCESS, THE BACKFLOW | | PERMIT AND GREASE INTERCEPTOR PERMITS ARE REQUIRED TO | | BE SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT | | (AS APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" | | (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR | | SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected] . YOU WILL RECEIVE INSTRUCTIONS | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE | | PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL | | CHANGE THE REVIEW STATUS TO PASS. | | | | 2.NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE DETAIL FOR | | SINK SHOWING HEIGHT, KNEE AND TOE SPACE. FRONT APPROACH | | FOR SINK IS SHOWN ON A1. COMPLY WITH FBC ACC 606.3, | | 306.2 AND 306.3. | | | | 3. SECOND REQUEST: MATERIAL SPEC PER WPB FBC 107.2.1, | | PROVIDE PIPING MATERIAL SPEC FOR EACH SYSTEM TO INCLUDE | | PIPE, VALVES, FITTINGS AND JOINTS. COMPLY WITH FBC PL | | CHAPTERS 3, 6, 7, 9 AND 11. | | PROVIDE SPECIFICATION 22 10 00 AS NOTED IN RESPONSE. | | | | 4.NEW COMMENT: A VENT IS REQUIRED FOR THE EXISTING | | FLOOR DRAIN PER FBC PL 901.2.1. | | | | 5.NEW COMMENT: PLEASE NOTE THAT PER FBC PL 301.7 AND | | 303.2, THE INSTALLATION OF THE SCHIER GB-75 GREASE | | INTERCEPTOR SHALL CONFORM TO A MINIMUM OF THE | | MANUFACTURER?S RECOMMENDATIONS. IN ACCORDANCE WITH THE | | GB-75 INSTALLATION MANUAL, A TWO-WAY CLEANOUT IS | | REQUIRED ON THE INLET AND OUTLET SIDE OF THE GREASE | | INTERCEPTOR. | | | | 6. NEW COMMENT: PER WPB FBC 107.2.1, TO SHOW COMPLIANCE | | WITH FBC PL 409.4, PROVIDE A NOTE ON P-4/DISHWASHING | | CONNECTION STATING "THE WASTE CONNECTION OF A | | RESIDENTIAL DISHWASHER SHALL CONNECT DIRECTLY TO A WYE | | BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK, | | DIRECTLY TO THE DISHWASHER CONNECTION OF A FOOD WASTE | | DISPOSER, OR THROUGH AN AIR BREAK TO A STANDPIPE. THE | | WASTE LINE OF A RESIDENTIAL DISHWASHER SHALL RISE AND | | BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM | | OR COUNTER TOP." | | | | 7.SECOND REQUEST: A WATER HAMMER ARRESTOR IS REQUIRED | | ON THE HOT WATER TO THE DISHWASHER PER FBC PL 604.9. | | PER WPB FBC 107.2.1, PROVIDE A WATER HAMMER ARRESTOR | | FOR THE HOT WATER TO THE DISHWASHER. THIS MAY BE | | ACCOMPLISHED BY PROVIDING A NOTE ON P-4/DISHWASHING | | CONNECTION. | | | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-02-01 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-02-01 |
Time |
09:16 |
Sent To |
|
|
Notes |
2022-02-01 12:13:59 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 21121220 4920 LORING DR | | | | 1ST REVIEW | | PLUMBING COMMENTS: DENIED | | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | APPROVAL. | | | | 1. PER FBC ACC 212.3, WHERE SINKS ARE PROVIDED, AT | | LEAST 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE | | PROVIDED IN EACH ACCESSIBLE ROOM OR SPACE SHALL COMPLY | | WITH 606. | | | | 2. MATERIAL SPEC PER WPB FBC 107.2.1, PROVIDE PIPING | | MATERIAL SPEC FOR EACH SYSTEM TO INCLUDE PIPE, VALVES, | | FITTINGS AND JOINTS. COMPLY WITH FBC PL CHAPTERS 3, 6, | | 7, 9 AND 11. | | | | 3. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH | | A NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN | | ACCORDANCE WITH FBC PL TABLE 308.5." | | | | 4. PER WPB FBC 107.2.1, PROVIDE A SLAB REPAIR DETAIL ON | | THE PLANS. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM | | THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED. SHOW | | SIZE, LENGTH, SPACING (ON CENTER), MINIMUM EMBEDMENT | | AND ANCHORING/ADHESIVE MATERIAL FOR DOWELS. THE REPAIR | | SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AS | | WELL AS THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED | | SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE | | FOR FINAL INSPECTION. | | | | 5. PER WPB FBC 107.2.1 AND 107.3.5.1.3 , PROVIDE A | | SCHEDULE, CALCULATIONS AND DETAIL OF THE GREASE | | INTERCEPTOR SHOWING COMPLIANCE WITH FBC PL 1003.3.5 AND | | 1003.3.5.1. | | | | 6. PER WPB FBC 107.2.1 AND 107.3.5.1.3, PROVIDE THE | | FOLLOWING: | | ?A) A DETAIL FOR THE SEPARATE DISCHARGES OF THE GREASY | | WASTE AND THE DISPOSAL WASTE FROM THE NEW SINK TO | | SANITARY; INCLUDE THE DISCHARGE FROM THE DISHWASHER. | | ?B) CLEARLY SHOW ON THE SANITARY RISER DIAGRAM TWO | | SEPARATE TRAPPED AND VENTED FIXTURE DRAINS FOR THE | | DISPOSAL AND FOR SINK/DISHWASHER. | | ?C) PROVIDE SIZING FOR ALL NEW DRAINS ON THE SANITARY | | RISER DIAGRAM. | | | | 7. P-2, DEMO NOTE 5 INDICATES AN EXISTING FLOOR DRAIN | | IS TO REMAIN. PER WPB FBC 107.2.1, INDICATE HOW THE | | EXISTING TRAP SEAL PROTECTION IS TO REMAIN. IF | | CONDITIONS DO NOT ALLOW THE EXISTING PROTECTION TO | | REMAIN INTACT, PROVIDE NEW DETAIL/SPECIFICATION FOR | | TRAP SEAL PROTECTION COMPLYING WITH ONE OF THE | | FOLLOWING: FBC 1002.4.1.1, 1002.4.1.2, 1002.4.1.3 OR | | 1002.4.1.4. | | | | 8. PER WPB FBC 107.2.1 AND 107.3.5.1.3, CLEARLY SHOW ON | | THE WATER RISER DIAGRAM THE FOLLOWING: | | ?A) A WATER HAMMER ARRESTOR FOR THE HOT WATER TO THE | | DISHWASHER SHOWING COMPLIANCE WITH FBC PL 604.9. | | ?B) IDENTIFY THE DISHWASHER CONNECTION. | | ?C) PROVIDE SIZING FOR ALL NEW BRANCHES. | | | | 9. PER WPB FBC 107.2.1 AND 107.3.5.1.3, PROVIDE | | CALCULATIONS FOR SIZING OF WATER DISTRIBUTION AND | | SANITARY DRAINS. | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-07-12 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-07-12 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-06-03 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-03 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-03 |
Time |
12:59 |
Sent To |
|
|
Notes |
2022-06-03 13:04:57 | SIGNATURE REVIEW FAILED | | !) SHEETS A1,A2 AND A3 DO NOT APPEAR TO HAVE THE | | REQUIRED SEAL AND SIGNATURE. | | | | PLEASE FOLLOW THE DIRECTIONS OUTLINED BELOW TO CORRECT | | THIS ISSUE.FS471/FS481 DOCUMENTS PREPARED BY AN | | ARCHITECT OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD | | ARE TO BE SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY | | SEALED AND SIGNED. | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING | | DEPARTMENT. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | DOCUMENTS ARE PREFERRED. | | PLEASE EMAIL [email protected] AND CC TO | | [email protected] WITH ANY QUESTIONS | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | 2022-05-31 06:56:15 | DIGIAL SIGNATURE FOR MECHANICAL APPROVED ME | 2022-05-24 12:17:07 | SIGNATURES FOR PLUMBING ARE VALID. JS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-04-04 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-04-04 |
Time |
16:41 |
Sent To |
|
|
Notes |
2022-03-29 16:34:00 | PLUMBING SIGNATURES VALID JS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-02-14 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-02-14 |
Time |
14:24 |
Sent To |
|
|
Notes |
|
|