Plan Review Stops For Permit 21121211 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-09-07 13:58:58 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-06-29 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-06-29 11:28:03 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-03-09 |
Time |
13:23 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-03-09 13:23:36 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-06-29 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-03-09 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-03-09 |
Time |
13:23 |
Sent To |
|
|
Notes |
2022-03-09 15:17:45 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 21121211 | | ADD: 2300 VILLAGE BLVD. | | CONT: TBD/ TO BE DETERMINED | | TEL: | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. MARCH 09TH/2022 | | ACTION: DENIED | | | | 1) 1S FLOOR PLAN CODE ANALYSIS STATES THE APPLICABLE | | CODES ARE THE 2017 FAMILY OF FBC. UPDATE PLAN, THE | | 2020FBC- FAMILY OF CODES WAS ADOPTED STATEWIDE DEC. 31/ | | 2020. | | | | | | 2)SHEET A-4: | | | | 2A) BEAUTY/ BARBER SHOP. PLEASE SHOW COMPLIANCE WITH | | THE 2020 FBC-BUILDING CODE SECTION 450.3.4.4 A BARBER/ | | BEAUTY ROOM, THE AREA OF THE ROOM SHALL BE A MINIMUM OF | | 120 SQUARE FEET WITH THE LEAST DIMENSION OF 10 FEET. | | THE NINE FEET SIX INCHES IS 9 FEET 2 INCHES INSIDE OF | | THE ROOM FINISH TO FINISH AND LESS THAN 120 SQUARE | | FEET, 120 SQUARE FEET IS MINIMUM ROOM SIZE. | | | | 2B) PLEASE PROVIDE THE WIDTH OF DOOR #1,2, 3 & 4. 2020 | | FBC-B 1010.1.1. SIZE OF DOORS. CLEAR WIDTH. DOOR | | OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS | | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE | | STOP, WITH THE DOOR OPEN AT 90 DEGREES. | | | | 3) GUIDELINES HEALTH CARE FACILITIES (3.10 RENAL | | DIALYSIS UNIT (ACUTE & CHRONIC): | | 3A) 2.2.2.1 SPACE REQUIREMENTS | | (1) AREA. INDIVIDUAL PATIENT TREATMENT AREAS SHALL | | CONTAIN AT LEAST 80 SQ. FT. EXCLUSIVE OF GENERAL | | CIRCULATION SPACE WITHIN WARD. | | (2) CLEARANCE. THERE SHALL BE AT LEAST A 4-FOOT SPACE | | BETWEEN BEDS AND OR LOUNGE CHAIRS. | | | | 3B) PRIVACY. 2.2.2.2. THE OPEN UNIT SHALL BE DESIGNED | | TO PROVIDE PRIVACY FOR EACH PATIENT. | | | | 3C) 2.2.4.2. HAND WASHING STATION. THERE SHALL BE AT | | LEAST ONE HAND WASHING STATION SERVING NO MORE THAN | | FOUR STATIONS. THE HAND WASHING STATIONS SHALL BE | | UNIFORMLY DISTRIBUTED TO PROVIDE EQUAL ACCESS FROM EACH | | PATIENT STATION. | | | | 3D) 3.2.2.1 CLEAN ROOM STORAGE. LOCATION OF THE CLEAN | | LINEN STORAGE AREA WITHIN THE CLEAN WORKROOM, A | | SEPARATE CLOSET. OR AN APPROVED DISTRIBUTION SYSTEM | | SHALL BE PERMITTED. | | | | 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | FROM CITY HALL. | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-10-05 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-10-05 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-10-05 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-30 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-30 |
Time |
13:55 |
Sent To |
|
|
Notes |
2022-06-30 13:58:19 | SEE SIGNATURE REVIEW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-03-02 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-03-02 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-03-02 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-09-07 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-09-07 10:26:42 | FIRE PROVISO NOTES: | | | | 1.) WITH THE REMOVAL AND/OR ADDITION OF WALLS, ENSURE | | CODE COMPLIANT FIRE SPRINKLER HEAD COVERAGE IS | | MAINTAINED. | | | | 2.) ALL FIRE ALARM AND/OR FIRE SPRINKLER WORK SHALL BE | | DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS BY | | QUALIFIED CONTRACTORS. | | | | C. WALKER | | | | 561-804-4762 | | | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-06-17 09:33:14 | FIRE PROVISO NOTES: | | 1.) WITH THE REMOVAL AND/OR ADDITION OF WALLS ENSURE | | CODE COMPLIANT SPRINKLER HEAD COVERAGE IS MAINTAINED. | | 2.) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE | | DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY | | QUALIFIED CONTRACTORS. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-01-27 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-01-27 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-01-27 11:37:04 | FIRE PROVISO NOTES: | | 1) WITH THE REMOVAL AND/OR ADDITION OF WALLS ENSURE | | CODE COMPLIANT SPRINKLER HEAD COVERAGE IS MAINTAINED. | | 2) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE DONE | | UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY QUALIFIED | | CONTRACTORS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-10-05 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-10-05 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-09-06 |
Time |
07:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-07-05 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-07-05 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-03-09 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2022-01-25 |
Time |
11:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-16 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-16 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-29 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-29 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-02-24 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-02-24 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-09-27 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-09-27 |
Time |
09:00 |
Sent To |
|
|
Notes |
2022-09-27 10:19:35 | 21121211 2300 VILLAGE BLVD | | | | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-07-05 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-06-30 |
Time |
15:06 |
Sent To |
|
|
Notes |
2022-07-05 11:12:51 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 21121211 2300 VILLAGE BLVD | | | | 2ND REVIEW | | PLUMBING COMMENTS: DENIED | | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | APPROVAL. | | | | 1. SECOND REQUEST: PLAN SHEET A-1/CODE ANALYSIS: THE | | 2020 FLORIDA BUILDING CODES, SEVENTH EDITION INCLUSIVE | | OF FLORIDA BUILDING CODE ENERGY CONSERVATION, FLORIDA | | ACCESSIBILITY CODE 2020, FLORIDA EXISTING BUILDING CODE | | 2020, FLORIDA PLUMBING CODE 2020 AND FLORIDA FUEL GAS | | CODE 2020 7TH EDITION ARE THE APPLICABLE CODES. PER WPB | | FBC 107.2.1, PLEASE CORRECT. | | TO BE CLEAR, PROVIDE THE CURRENT EDITION DATE OF 2020 | | FOR THE APPLICABLE CODES | | NEW COMMENT: WPB AMENDMENTS TO THE FLORIDA BUILDING | | CODE (2017), CHAPTER 1, ADMINISTRATION SHALL BE LISTED, | | NOT THE PALM BEACH COUNTY AMENDMENTS | | | | 2. COMPLIED | | | | 3. SECOND REQUEST: PER WPB FBC 107.2.1, PLEASE CONFIRM | | THAT THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER | | PIPING IS WITHIN 50 FEET OF THE SOURCE OF HOT WATER AS | | DEFINED IN FBC PL 607.2. | | TO BE CLEAR, AN ACCEPTABLE SOURCE OF HOT WATER FOR HOT | | OR TEMPERED WATER IS A RECIRCULATING HOT WATER SYSTEM | | OR A HEAT TRACED PIPING SYSTEM, (OR A WATER HEATER) NOT | | A MIXING VALVE. FBC PL 607.2. | | PER WPB FBC 107.2.1, PLEASE CLARIFY ON THE PLANS. | | | | LINE ITEMS 4 THROUGH 14. COMPLIED | | | | NEW COMMENTS: | | | | 1. NEW COMMENT: SPECIFIED LEONARD 6020-LF SERVICING | | EYEWASH DOES NOT COMPLY WITH ASSE 1071 AS REQUIRED BY | | FBC PL 411.3. PER WPB FBC 107.2.1, PROVIDE COMPLIANT | | TMV. | | | | 2. NEW COMMENT: PER FBC PL 608.1, PROVIDE RPZ IN HOT | | WATER LINE TO TMV SERVICING THE P-1 DIALYSIS BOXES. | | | | 3. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE | | SPECIFICATION AND DETAIL FOR RPZ, INCLUDING DISCHARGE | | WITH AIR GAP TO FLOOR SINK. | | | | 4. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE | | SPECIFICATION AND DETAIL FOR PRV WITH STRAINER TO | | REGULATE PRESSURE AT THE RPZ TO 25PSI MAX AS NOTED ON | | THE PLANS. COMPLY WITH FBC PL 604.8, 604.8.1 AND | | 604.8.2. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-02-03 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-02-03 |
Time |
11:36 |
Sent To |
|
|
Notes |
2022-02-03 16:16:06 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 21121211 2300 VILLAGE BLVD | | | | 1ST REVIEW | | PLUMBING COMMENTS: DENIED | | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | APPROVAL. | | | | 1. PLAN SHEET A-1/CODE ANALYSIS: THE 2020 FLORIDA | | BUILDING CODES, SEVENTH EDITION INCLUSIVE OF FLORIDA | | BUILDING CODE ENERGY CONSERVATION, FLORIDA | | ACCESSIBILITY CODE 2020, FLORIDA EXISTING BUILDING CODE | | 2020, FLORIDA PLUMBING CODE 2020 AND FLORIDA FUEL GAS | | CODE 2020 7TH EDITION ARE THE APPLICABLE CODES. PER WPB | | FBC 107.2.1, PLEASE CORRECT. | | | | 2. PER WPB FBC 107.2.1, PROVIDE DEMO PLAN SHOWING THE | | CURRENT CONDITIONS AND DIRECTION FOR | | REMOVAL/REMEDIATION OF EXISTING PLUMBING FIXTURES, | | EQUIPMENT AND PIPING. | | | | 3. PER WPB FBC 107.2.1, PLEASE CONFIRM THAT THE | | DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING IS | | WITHIN 50 FEET OF THE SOURCE OF HOT WATER AS DEFINED IN | | FBC PL 607.2. | | | | 4. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR PLUMBING | | FIXTURE ITEM P-4/SHAMPOO SINK; SPECIFY AND PROVIDE | | MANUFACTURER'S SPECIFICATION SHEETS/INSTALLATION MANUAL | | FOR THE HAIR TRAP/INTERCEPTOR. INDICATE THE INTERCEPTOR | | ON THE PIPING PLANS AND PROVIDE A DETAIL. | | | | 5. PER WPB FBC 107.2.1, ADD FIXTURE TAG (I.E. P-1, P-2, | | ETC.) TO FIXTURES ON RISER DIAGRAMS AND RECONCILE WITH | | PLAN VIEW. | | | | 6. FIXTURE P-3 SINK COMES WITH EYEWASH INTEGRAL WITH | | THE FAUCET. WATER RISER DIAGRAM SHOWS EYEWASH AS A | | SEPARATE ENTITY WITH A TWO SEPARATE THERMAL MIXING | | VALVES, ONE FOR THE SINK FAUCET AND ONE FOR THE | | EYEWASH. PER WPB FBC 107.2.1, PLEASE CLARIFY. | | | | 7. PLAN SHEET P-1 AND P-2 SHOW THE P-5 EYEWASH AT | | OPPOSITE P-2 SINKS. PER WPB FBC 107.2.1, PLEASE CLARIFY | | AND RECONCILE. | | | | 8. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR PLUMBING | | FIXTURE ITEM P-1/DIALYSIS BOX. | | | | 9. PLAN SHEET P-1/PLUMBING GENERAL NOTE 8 REQUIRES PVC | | FOR SANITARY PIPING IF APPROVED BY LOCAL CODE, | | OTHERWISE USE CAST IRON. PRIOR TO INSPECTION, A PLAN | | REVISION REFLECTING THE ACTUAL MATERIAL SHALL BE | | SUBMITTED TO THE BUILDING DEPARTMENT, APPROVED AND ON | | SITE. WPB FBC 107.2.1. | | | | 10. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL | | BE LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND | | 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS | | STATING THE SAME. | | | | 11. PER WPB FBC 107.2.1, PROVIDE APPLICABLE RATED | | WALL/FLOOR DETAILS FOR PLUMBING PIPE PENETRATIONS | | COMPLYING WITH THE REQUIREMENTS OF FBC CHAPTER 7. | | | | 12. PER WPB FBC 107.2.1, PROVIDE A NOTE ON THE PIPE | | HANGER DETAIL STATING, "HORIZONTAL PIPE SHALL BE | | SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5." | | | | 13. PER WPB FBC 107.2.1, PROVIDE CALCULATIONS FOR | | SIZING OF SANITARY AND WATER DISTRIBUTION. | | | | 14. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR DIALYSIS | | EQUIPMENT. THIS MAY BE DONE AS A DEFERRED SUBMITTAL IN | | ACCORDANCE WITH WPB FBC 107.3.4.2. THE ITEMS SHALL BE | | LISTED ON THE PLANS AS DEFERRED SUBMITTALS TO BE | | SUBMITTED TO THE BUILDING OFFICIAL, APPROVED AND ON | | SITE PRIOR TO FINAL INSPECTION. PROCEED AT YOUR OWN | | RISK. | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | | | 21121211 2300 VILLAGE BLVD | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-16 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-10-05 |
Time |
14:10 |
Sent To |
|
|
Notes |
2022-10-05 14:11:27 | ALL PLANS PASSED SIGNATURE REVIEW. MP | 2022-09-27 10:21:20 | DIGITAL SIGNATURES FOR PLUMBING PLANS ARE APPROVED. JS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-30 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-30 |
Time |
13:58 |
Sent To |
|
|
Notes |
2022-07-05 11:08:58 | PLUMBING PLANS ARE NOT DIITALLY SIGNED. JS | 2022-06-30 13:59:15 | SEE PREVIOUS SIGNATURE REVIEW COMMENTS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-03-09 |
Time |
15:21 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-03-09 15:21:41 | IT APPEARS THESE WER PAPER PLANS THAT WERE UPLOADED TO | | BECOME DIGITAL PLANS. FLORIDA ADMINISTRATIVE CODE | | 61G15-23.005 (3)(C) PLANS IN THE FILE FOLDER, SCANNED, | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | ELECTRONIC/DIGITALLY SIGNED AND SEALED ENGINEERING | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
|
|