Plan Review Details - Permit 21121211
Plan Review Stops For Permit 21121211
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2022-09-07 Cont ID  
Sent By jwitmer Date 2022-09-07 Time 13:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-09-07 13:58:58COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-06-29 Cont ID  
Sent By jwitmer Date 2022-06-29 Time 11:28 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-06-29 11:28:03COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By jwitmer Date 2022-03-09 Time 13:23 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-09 13:23:36COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-09-07 Cont ID  
Sent By jwitmer Date 2022-09-07 Time 14:07 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-29 Cont ID  
Sent By jwitmer Date 2022-06-29 Time 11:28 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By jwitmer Date 2022-03-09 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2022-03-09 Time 13:23 Sent To  
Notes
2022-03-09 15:17:45WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21121211
 ADD: 2300 VILLAGE BLVD.
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MARCH 09TH/2022
 ACTION: DENIED
  
 1) 1S FLOOR PLAN CODE ANALYSIS STATES THE APPLICABLE
 CODES ARE THE 2017 FAMILY OF FBC. UPDATE PLAN, THE
 2020FBC- FAMILY OF CODES WAS ADOPTED STATEWIDE DEC. 31/
 2020.
  
  
 2)SHEET A-4:
  
 2A) BEAUTY/ BARBER SHOP. PLEASE SHOW COMPLIANCE WITH
 THE 2020 FBC-BUILDING CODE SECTION 450.3.4.4 A BARBER/
 BEAUTY ROOM, THE AREA OF THE ROOM SHALL BE A MINIMUM OF
 120 SQUARE FEET WITH THE LEAST DIMENSION OF 10 FEET.
 THE NINE FEET SIX INCHES IS 9 FEET 2 INCHES INSIDE OF
 THE ROOM FINISH TO FINISH AND LESS THAN 120 SQUARE
 FEET, 120 SQUARE FEET IS MINIMUM ROOM SIZE.
  
 2B) PLEASE PROVIDE THE WIDTH OF DOOR #1,2, 3 & 4. 2020
 FBC-B 1010.1.1. SIZE OF DOORS. CLEAR WIDTH. DOOR
 OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES
 MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS
 SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE
 STOP, WITH THE DOOR OPEN AT 90 DEGREES.
  
 3) GUIDELINES HEALTH CARE FACILITIES (3.10 RENAL
 DIALYSIS UNIT (ACUTE & CHRONIC):
 3A) 2.2.2.1 SPACE REQUIREMENTS
 (1) AREA. INDIVIDUAL PATIENT TREATMENT AREAS SHALL
 CONTAIN AT LEAST 80 SQ. FT. EXCLUSIVE OF GENERAL
 CIRCULATION SPACE WITHIN WARD.
 (2) CLEARANCE. THERE SHALL BE AT LEAST A 4-FOOT SPACE
 BETWEEN BEDS AND OR LOUNGE CHAIRS.
  
 3B) PRIVACY. 2.2.2.2. THE OPEN UNIT SHALL BE DESIGNED
 TO PROVIDE PRIVACY FOR EACH PATIENT.
  
 3C) 2.2.4.2. HAND WASHING STATION. THERE SHALL BE AT
 LEAST ONE HAND WASHING STATION SERVING NO MORE THAN
 FOUR STATIONS. THE HAND WASHING STATIONS SHALL BE
 UNIFORMLY DISTRIBUTED TO PROVIDE EQUAL ACCESS FROM EACH
 PATIENT STATION.
  
 3D) 3.2.2.1 CLEAN ROOM STORAGE. LOCATION OF THE CLEAN
 LINEN STORAGE AREA WITHIN THE CLEAN WORKROOM, A
 SEPARATE CLOSET. OR AN APPROVED DISTRIBUTION SYSTEM
 SHALL BE PERMITTED.
  
 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-10-05 Cont ID  
Sent By mpeterso Date 2022-10-05 Time 14:10 Rev Time 0.00
Received By mpeterso Date 2022-10-05 Time 14:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 13:55 Rev Time 0.00
Received By mpeterso Date 2022-06-30 Time 13:55 Sent To  
Notes
2022-06-30 13:58:19SEE SIGNATURE REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-02 Cont ID  
Sent By mpeterso Date 2022-03-02 Time 14:18 Rev Time 0.00
Received By mpeterso Date 2022-03-02 Time 14:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-09-07 Cont ID  
Sent By cwalker Date 2022-09-07 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-09-07 10:26:42FIRE PROVISO NOTES:
  
 1.) WITH THE REMOVAL AND/OR ADDITION OF WALLS, ENSURE
 CODE COMPLIANT FIRE SPRINKLER HEAD COVERAGE IS
 MAINTAINED.
  
 2.) ALL FIRE ALARM AND/OR FIRE SPRINKLER WORK SHALL BE
 DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS BY
 QUALIFIED CONTRACTORS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-17 Cont ID  
Sent By cwalker Date 2022-06-17 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-06-17 09:33:14FIRE PROVISO NOTES:
 1.) WITH THE REMOVAL AND/OR ADDITION OF WALLS ENSURE
 CODE COMPLIANT SPRINKLER HEAD COVERAGE IS MAINTAINED.
 2.) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE
 DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY
 QUALIFIED CONTRACTORS.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-01-27 Cont ID  
Sent By cwalker Date 2022-01-27 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-01-27 11:37:04FIRE PROVISO NOTES:
 1) WITH THE REMOVAL AND/OR ADDITION OF WALLS ENSURE
 CODE COMPLIANT SPRINKLER HEAD COVERAGE IS MAINTAINED.
 2) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE DONE
 UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY QUALIFIED
 CONTRACTORS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-05 Cont ID  
Sent By mpeterso Date 2022-10-05 Time 14:11 Rev Time 0.00
Received By mpeterso Date 2022-09-06 Time 07:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-05 Cont ID  
Sent By jesmith Date 2022-07-05 Time 11:15 Rev Time 0.00
Received By jesmith Date 2022-07-05 Time 11:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-03-09 Time   Rev Time 0.00
Received By cdecoeur Date 2022-01-25 Time 11:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-09-16 Cont ID  
Sent By medwards Date 2022-09-16 Time 10:07 Rev Time 0.00
Received By medwards Date 2022-09-16 Time 10:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-29 Cont ID  
Sent By medwards Date 2022-06-29 Time 08:42 Rev Time 0.00
Received By medwards Date 2022-06-29 Time 08:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By medwards Date 2022-02-24 Time 08:58 Rev Time 0.00
Received By medwards Date 2022-02-24 Time 08:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-09-27 Cont ID  
Sent By jesmith Date 2022-09-27 Time 10:19 Rev Time 0.00
Received By jesmith Date 2022-09-27 Time 09:00 Sent To  
Notes
2022-09-27 10:19:3521121211 2300 VILLAGE BLVD
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-07-05 Cont ID  
Sent By jesmith Date 2022-07-05 Time 11:13 Rev Time 0.00
Received By jesmith Date 2022-06-30 Time 15:06 Sent To  
Notes
2022-07-05 11:12:51CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21121211 2300 VILLAGE BLVD
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1. SECOND REQUEST: PLAN SHEET A-1/CODE ANALYSIS: THE
 2020 FLORIDA BUILDING CODES, SEVENTH EDITION INCLUSIVE
 OF FLORIDA BUILDING CODE ENERGY CONSERVATION, FLORIDA
 ACCESSIBILITY CODE 2020, FLORIDA EXISTING BUILDING CODE
 2020, FLORIDA PLUMBING CODE 2020 AND FLORIDA FUEL GAS
 CODE 2020 7TH EDITION ARE THE APPLICABLE CODES. PER WPB
 FBC 107.2.1, PLEASE CORRECT.
 TO BE CLEAR, PROVIDE THE CURRENT EDITION DATE OF 2020
 FOR THE APPLICABLE CODES
 NEW COMMENT: WPB AMENDMENTS TO THE FLORIDA BUILDING
 CODE (2017), CHAPTER 1, ADMINISTRATION SHALL BE LISTED,
 NOT THE PALM BEACH COUNTY AMENDMENTS
  
 2. COMPLIED
  
 3. SECOND REQUEST: PER WPB FBC 107.2.1, PLEASE CONFIRM
 THAT THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER
 PIPING IS WITHIN 50 FEET OF THE SOURCE OF HOT WATER AS
 DEFINED IN FBC PL 607.2.
 TO BE CLEAR, AN ACCEPTABLE SOURCE OF HOT WATER FOR HOT
 OR TEMPERED WATER IS A RECIRCULATING HOT WATER SYSTEM
 OR A HEAT TRACED PIPING SYSTEM, (OR A WATER HEATER) NOT
 A MIXING VALVE. FBC PL 607.2.
 PER WPB FBC 107.2.1, PLEASE CLARIFY ON THE PLANS.
  
 LINE ITEMS 4 THROUGH 14. COMPLIED
  
 NEW COMMENTS:
  
 1. NEW COMMENT: SPECIFIED LEONARD 6020-LF SERVICING
 EYEWASH DOES NOT COMPLY WITH ASSE 1071 AS REQUIRED BY
 FBC PL 411.3. PER WPB FBC 107.2.1, PROVIDE COMPLIANT
 TMV.
  
 2. NEW COMMENT: PER FBC PL 608.1, PROVIDE RPZ IN HOT
 WATER LINE TO TMV SERVICING THE P-1 DIALYSIS BOXES.
  
 3. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE
 SPECIFICATION AND DETAIL FOR RPZ, INCLUDING DISCHARGE
 WITH AIR GAP TO FLOOR SINK.
  
 4. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE
 SPECIFICATION AND DETAIL FOR PRV WITH STRAINER TO
 REGULATE PRESSURE AT THE RPZ TO 25PSI MAX AS NOTED ON
 THE PLANS. COMPLY WITH FBC PL 604.8, 604.8.1 AND
 604.8.2.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-03 Cont ID  
Sent By jesmith Date 2022-02-03 Time 16:28 Rev Time 0.00
Received By jesmith Date 2022-02-03 Time 11:36 Sent To  
Notes
2022-02-03 16:16:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21121211 2300 VILLAGE BLVD
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1. PLAN SHEET A-1/CODE ANALYSIS: THE 2020 FLORIDA
 BUILDING CODES, SEVENTH EDITION INCLUSIVE OF FLORIDA
 BUILDING CODE ENERGY CONSERVATION, FLORIDA
 ACCESSIBILITY CODE 2020, FLORIDA EXISTING BUILDING CODE
 2020, FLORIDA PLUMBING CODE 2020 AND FLORIDA FUEL GAS
 CODE 2020 7TH EDITION ARE THE APPLICABLE CODES. PER WPB
 FBC 107.2.1, PLEASE CORRECT.
  
 2. PER WPB FBC 107.2.1, PROVIDE DEMO PLAN SHOWING THE
 CURRENT CONDITIONS AND DIRECTION FOR
 REMOVAL/REMEDIATION OF EXISTING PLUMBING FIXTURES,
 EQUIPMENT AND PIPING.
  
 3. PER WPB FBC 107.2.1, PLEASE CONFIRM THAT THE
 DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING IS
 WITHIN 50 FEET OF THE SOURCE OF HOT WATER AS DEFINED IN
 FBC PL 607.2.
  
 4. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S
 SPECIFICATION SHEETS/INSTALLATION MANUAL FOR PLUMBING
 FIXTURE ITEM P-4/SHAMPOO SINK; SPECIFY AND PROVIDE
 MANUFACTURER'S SPECIFICATION SHEETS/INSTALLATION MANUAL
 FOR THE HAIR TRAP/INTERCEPTOR. INDICATE THE INTERCEPTOR
 ON THE PIPING PLANS AND PROVIDE A DETAIL.
  
 5. PER WPB FBC 107.2.1, ADD FIXTURE TAG (I.E. P-1, P-2,
 ETC.) TO FIXTURES ON RISER DIAGRAMS AND RECONCILE WITH
 PLAN VIEW.
  
 6. FIXTURE P-3 SINK COMES WITH EYEWASH INTEGRAL WITH
 THE FAUCET. WATER RISER DIAGRAM SHOWS EYEWASH AS A
 SEPARATE ENTITY WITH A TWO SEPARATE THERMAL MIXING
 VALVES, ONE FOR THE SINK FAUCET AND ONE FOR THE
 EYEWASH. PER WPB FBC 107.2.1, PLEASE CLARIFY.
  
 7. PLAN SHEET P-1 AND P-2 SHOW THE P-5 EYEWASH AT
 OPPOSITE P-2 SINKS. PER WPB FBC 107.2.1, PLEASE CLARIFY
 AND RECONCILE.
  
 8. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S
 SPECIFICATION SHEETS/INSTALLATION MANUAL FOR PLUMBING
 FIXTURE ITEM P-1/DIALYSIS BOX.
  
 9. PLAN SHEET P-1/PLUMBING GENERAL NOTE 8 REQUIRES PVC
 FOR SANITARY PIPING IF APPROVED BY LOCAL CODE,
 OTHERWISE USE CAST IRON. PRIOR TO INSPECTION, A PLAN
 REVISION REFLECTING THE ACTUAL MATERIAL SHALL BE
 SUBMITTED TO THE BUILDING DEPARTMENT, APPROVED AND ON
 SITE. WPB FBC 107.2.1.
  
 10. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL
 BE LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND
 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS
 STATING THE SAME.
  
 11. PER WPB FBC 107.2.1, PROVIDE APPLICABLE RATED
 WALL/FLOOR DETAILS FOR PLUMBING PIPE PENETRATIONS
 COMPLYING WITH THE REQUIREMENTS OF FBC CHAPTER 7.
  
 12. PER WPB FBC 107.2.1, PROVIDE A NOTE ON THE PIPE
 HANGER DETAIL STATING, "HORIZONTAL PIPE SHALL BE
 SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5."
  
 13. PER WPB FBC 107.2.1, PROVIDE CALCULATIONS FOR
 SIZING OF SANITARY AND WATER DISTRIBUTION.
  
 14. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S
 SPECIFICATION SHEETS/INSTALLATION MANUAL FOR DIALYSIS
 EQUIPMENT. THIS MAY BE DONE AS A DEFERRED SUBMITTAL IN
 ACCORDANCE WITH WPB FBC 107.3.4.2. THE ITEMS SHALL BE
 LISTED ON THE PLANS AS DEFERRED SUBMITTALS TO BE
 SUBMITTED TO THE BUILDING OFFICIAL, APPROVED AND ON
 SITE PRIOR TO FINAL INSPECTION. PROCEED AT YOUR OWN
 RISK.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21121211 2300 VILLAGE BLVD
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-09-16 Cont ID  
Sent By medwards Date 2022-09-16 Time 10:09 Rev Time 0.00
Received By mpeterso Date 2022-10-05 Time 14:10 Sent To  
Notes
2022-10-05 14:11:27ALL PLANS PASSED SIGNATURE REVIEW. MP
2022-09-27 10:21:20DIGITAL SIGNATURES FOR PLUMBING PLANS ARE APPROVED. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 13:58 Rev Time 0.00
Received By mpeterso Date 2022-06-30 Time 13:58 Sent To  
Notes
2022-07-05 11:08:58PLUMBING PLANS ARE NOT DIITALLY SIGNED. JS
2022-06-30 13:59:15SEE PREVIOUS SIGNATURE REVIEW COMMENTS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By jwitmer Date 2022-03-09 Time 15:21 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-03-09 15:21:41IT APPEARS THESE WER PAPER PLANS THAT WERE UPLOADED TO
 BECOME DIGITAL PLANS. FLORIDA ADMINISTRATIVE CODE
 61G15-23.005 (3)(C) PLANS IN THE FILE FOLDER, SCANNED,
 FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE
 LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONIC/DIGITALLY SIGNED AND SEALED ENGINEERING
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.