2022-01-18 11:13:08 | ** FAILED ** |
| |
| PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE |
| COMMENTS IN WRITING AND/OR ON THE PLANS WHERE |
| APPLICABLE: |
| |
| *** ALL 3 WALL SIGN PERMITS, ON WEST/FRONT BUILDING |
| FACADE (#21121179, #21121180 AND #21121181) ARE BEING |
| REVIEWED TOGETHER FOR CONSISTENCY. CURRENTLY, |
| INFORMATION PROVIDED IN THE PERMIT SET(S) IS NOT |
| ACCURATE TO CONDUCT A FULL ZONING REVIEW FOR WALL |
| SIGNAGE. *** |
| |
| 1,) BUILDING FACADE CALCULATIONS ARE INACCURATE BASED |
| ON STAFF'S MEASUREMENTS ACCORDING TO THE APPROVED PLANS |
| (ISPR CASE NO. 20-09) AND INFORMATION PROVIDED FROM THE |
| PALM BEACH COUNTY PROPERTY APPRAISER'S WEBSITE. STAFF'S |
| DIMENSIONS OF THE BUILDING FACADE ARE AS FOLLOWS: |
| BUILDING HEIGHT = 15.67 FT. (NOT 20 FT.) AND BUILDING |
| LENGTH = 105 FT. (NOT 106 FT.). BASED ON STAFF'S |
| CALCULATIONS, THE BUILDING FACADE IS 1,645 SQ. FT. (NOT |
| 2,120 SQ. FT.). PLEASE ADDRESS FOR ACCURACY. THE |
| ACCURATE BUILDING FACADE DIMENSIONS WILL ALSO REDUCE |
| THE MAXIMUM ALLOWABLE SIGN AREA PERMITTED. [ZLDR |
| S.94-405 AND 94-409] |
| |
| 2.) SIGN AREA FOR EACH SIGNAGE SHALL BE THE AREA OF THE |
| SMALLEST CIRCLE, TRIANGLE, OR PARALLELOGRAM, WHICH |
| CONTAINS ALL CONTENT, BACKGROUND, AND STRUCTURAL |
| ELEMENTS OF THE SIGN. ACCORDING TO THE PLANS PROVIDED, |
| CALCULATIONS FOR SIGN A DOES NOT COMPLY WITH THIS |
| STANDARD. [ZLDR S.94-405] |
| |
| 3.) THE BUILDING SHALL HAVE A MAXIMUM OF 3 SIGNS TOTAL. |
| ACCORDING TO THE PLANS SUBMITTED, THE FRONT (WEST |
| FACADE) WILL PROVIDE ALL 3 SIGNS FOR THE BUILDING (NO |
| MORE WALL SIGN WILL BE PERMITTED.). ACCORDING TO SEC. |
| 94-408.D.1.B. OF THE ZONING AND LAND DEVELOPMENT |
| REGULATIONS (ZLDRS), THE MAXIMUM ALLOWABLE SIGN AREA |
| SHALL BE 2% LESS THAN THE AREA DESIGNATED IN SEC. |
| 94-409 OF THE ZLDRS. |
| |
| |
| NOTES: |
| |
| * CONDITIONS OF APPROVAL FROM ISPR CASE NO. 20-09 MUST |
| BE SATISFIED. PLEASE CONTACT STAFF FOR THE CONDITIONAL |
| APPROVAL LETTER ISSUED BY PLANNING STAFF ON 5/19/2021. |
| |
| * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. |
| |
| * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| QUESTIONS. |
| |
| * ZONE: GC |
| |
| * REFERENCE: ISPR CASE NO. 20-09 - CONDITIONS OF |
| APPROVAL APPLY |
| |
| * REFERENCE: |
| - SIGN A: #21121179 |
| - SIGN B: #21121180 |
| - SIGN C: #21121181 |
| |