Plan Review Details - Permit 21121068
Plan Review Stops For Permit 21121068
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-01-07 Cont ID  
Sent By cpuell Date 2022-01-07 Time 09:19 Rev Time 0.00
Received By cpuell Date 2022-01-07 Time 09:19 Sent To  
Notes
2022-01-07 09:21:38ADDRESS CHANGED FROM 445 FOREST HILL BLVD TO 6760
 NORTON AVE, UPDATED PERMIT.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-01-06 Cont ID  
Sent By cpuell Date 2022-01-06 Time 15:18 Rev Time 0.00
Received By cpuell Date 2022-01-06 Time 15:18 Sent To  
Notes
2022-01-06 15:18:57PROPOSED A NEW ADDRESS OF 6760 FOREST HILL BLVD,
 WAITING TO HEAR FROM OWNER.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-01-03 Cont ID  
Sent By cpuell Date 2022-01-03 Time 14:51 Rev Time 0.00
Received By cpuell Date 2022-01-03 Time 14:51 Sent To  
Notes
2022-01-03 14:52:24A NEW ADDRESS NEEDS TO BE STABLISHED AS THE MAIN
 ENTRANCE FACES NORTON AVE. PLEASE HAVE THE OWNER
 CONTACT [email protected] OR CALL 561-805-6659 TO DISCUSS
 ADDRESSING OPTIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 16:45 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 16:45 Sent To  
Notes
2022-05-16 16:45:49BUILDING REVIEW APPROVED WITH PROVISO:
 (NOTE: PROVIDE INFORMATION PRIOR TO
 INSTALLATION/INSPECTIONS TO AVOID CONFLICTS/DELAYS).
 1- REVISE SURVEY/DRAINAGE PLAN SHOWING THE EXISTING AND
 PROPOSED GRADE ELEVATIONS SHOWING HOW KEEPING WATER
 AWAY FROM NEIGHBOR ON THE EAST SIDE OF PROPERTY. AND,
 PROVIDE DETAILS FOR SWALES OR ANY OTHER METHOD OF
 COMPLIANCE.
  
 2- REVISE SOFFIT SPECIFICATIONS. 3/8" RIB LATH ARE NOT
 FLAT RIB. ALSO, 6D NAILS DON'T PROVIDE 1-3/4"
 EMBEDMENT. NEED TO USE ALT LEAST 2-1/2' LONG NAILS
 (GALVANIZED ROOFING NAILS OR GALVANIZED COMMON NAILS).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 16:03 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 14:25 Sent To  
Notes
2022-05-16 16:03:17NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21121068
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ORIGINAL COMMENT:
 1-SURVEY/DRAINAGE PLAN SUBMITTED:
 A)SITE PLAN & BOUNDARY SURVEY SUBMITTED SHOW "PROPOSED
 RETAINING WALL" ON THE EAST SIDE. CLEARLY IDENTIFY
 LOCATION OF PROPOSED RETAINING WALL. AND, PROVIDE
 COMPLETE DETAILS/SPECIFICATIONS FOR THE RETAINING WALL
 CONSTRUCTION. SEC. 107.2.5 CITY AMENDMENTS. R401.3
 FBC-RESIDENTIAL.
  
 RESPONSE:
 SURVEY/DRAINAGE PLAN WAS REVISED. RETAINING WALL WAS
 DELETED. REVISED SURVEY DOESN'T SHOW HOW THE WATER IS
 RETAINED WITHING THE LOT ON THE EAST SIDE. NOTE:
 DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED GRADE
 ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM ADJACENT
 PROPERTIES. AND, THERE ARE NOT DETAILS LIKE SWALES
 SHOWING HOW THE WATER IS RUNNING TOWARD THE FRONT AND
 REAR OF PROPERTY.
  
 B)OK. NOT RETAINING WALL.
  
 2- OK.
  
 ORIGINAL COMMENT:
 3- WIND RESISTANCE OF EXTERIOR SOFFITS:
 TYPICAL WALL SECTION ON SHEET 3-4 ONLY SPECIFIES
 "METHAL LATH AND STUCCO SOFFIT W/ 7"X24" SCREENED VENTS
 @ 8'-0" O.C.". THERE ARE NO SPECIFICATIONS FOR
 SHEATHING TO SUPPORT THE METHAL LATH. ENGINEER OF
 RECORD TO PROVIDE CALCULATIONS SHOWING THAT THIS SOFFIT
 SPECIFICATIONS WITHOUT SHEATHING ARE ADEQUATE TO RESIST
 THE WIND LOADS AS REQUIRED BY SEC. R704 FBC-RESIDENTIAL
 OR REVISE DETAIL PROVIDING COMPLETE SHEATHING
 SPECIFICATIONS (MATERIAL, THICKNESS AND FASTENING).
 SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 CLARIFY/REVISE SOFFIT SPECIFICATIONS. SPECIFICATIONS
 CALL FOR 3/8" FLAT RIB LATH. 3/8" RIB LATH ARE NOT FLAT
 RIB. 3/8" RIB LATH ARE ALSO CALLED HIGH RIB OR EXPANDED
 METHAL LATH NOT FLAT RIB. ALSO, 6D NAILS DON'T PROVIDE
 1-3/4" EMBEDMENT. NEED TO USE ALT LEAST 2-1/2' LONG
 NAILS (GALVANIZED ROOFING NAILS OR GALVANIZED COMMON
 NAILS).
  
 4- OK.
 5- OK.
 6- OK.
 7- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-08 Cont ID  
Sent By jgomez Date 2022-03-08 Time 18:37 Rev Time 0.00
Received By jgomez Date 2022-03-08 Time 13:06 Sent To  
Notes
2022-03-08 18:40:46NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21121068
  
 1-SURVEY/DRAINAGE PLAN SUBMITTED:
 A)SITE PLAN & BOUNDARY SURVEY SUBMITTED SHOW "PROPOSED
 RETAINING WALL" ON THE EAST SIDE. CLEARLY IDENTIFY
 LOCATION OF PROPOSED RETAINING WALL. AND, PROVIDE
 COMPLETE DETAILS/SPECIFICATIONS FOR THE RETAINING WALL
 CONSTRUCTION. SEC. 107.2.5 CITY AMENDMENTS. R401.3
 FBC-RESIDENTIAL.
  
 B)A SEPARATE PERMIT WILL BE REQUIRED FOR THE
 CONSTRUCTION OF THE RETAINING WALL. SEC.105.1 CITY
 AMENDMENTS.
  
 2- ENERGY CALCULATIONS SUBMITTED:
 A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE
 CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 3- WIND RESISTANCE OF EXTERIOR SOFFITS:
 TYPICAL WALL SECTION ON SHEET 3-4 ONLY SPECIFIES
 "METHAL LATH AND STUCCO SOFFIT W/ 7"X24" SCREENED VENTS
 @ 8'-0" O.C.". THERE ARE NO SPECIFICATIONS FOR
 SHEATHING TO SUPPORT THE METHAL LATH. ENGINEER OF
 RECORD TO PROVIDE CALCULATIONS SHOWING THAT THIS SOFFIT
 SPECIFICATIONS WITHOUT SHEATHING ARE ADEQUATE TO RESIST
 THE WIND LOADS AS REQUIRED BY SEC. R704 FBC-RESIDENTIAL
 OR REVISE DETAIL PROVIDING COMPLETE SHEATHING
 SPECIFICATIONS (MATERIAL, THICKNESS AND FASTENING).
 SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 4-PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL):
  
 A)REAR FRENCH DOOR AS SHOWN ON PLANS.
  
 5-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVAL AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $256,270. THE
 PERMIT FEE BALANCE IS $1864.99.
  
 7- CLARIFY WHY SUBMITTING PRODUCT APPROVALS FOR
 OVERHEAD GARAGE DOORS AND SLIDING GLASS DOORS. DRAWINGS
 DON'T SHOW ANY. SEC. 107.2.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-26 Cont ID  
Sent By fgiaquin Date 2022-01-26 Time 11:48 Rev Time 0.00
Received By fgiaquin Date 2022-01-26 Time 10:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 16:23 Rev Time 0.00
Received By jgomez Date 2022-04-05 Time 08:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-08 Cont ID  
Sent By jgomez Date 2022-03-08 Time 18:42 Rev Time 0.00
Received By jgomez Date 2022-01-03 Time 05:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-05-24 Cont ID  
Sent By lmarchan Date 2022-05-24 Time 12:48 Rev Time 0.00
Received By lmarchan Date 2022-05-18 Time 15:35 Sent To  
Notes
2022-05-23 16:01:35RECEIPT MU-2022-023215 - $4133.44 PAID
2022-05-18 15:36:155/18/22 EMAILED IMPACT FOR REVIEW PER DB-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By jgomez Date 2022-03-08 Time 18:42 Rev Time 0.00
Received By jgomez Date 2022-03-08 Time 18:40 Sent To  
Notes
2022-03-09 10:38:22IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-04-18 Cont ID  
Sent By hmoser Date 2022-04-18 Time 11:18 Rev Time 0.00
Received By hmoser Date 2022-04-18 Time 11:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-01-06 Cont ID  
Sent By medwards Date 2022-01-06 Time 12:42 Rev Time 0.00
Received By medwards Date 2022-01-06 Time 12:30 Sent To  
Notes
2022-01-06 12:45:24SHEET M-1: THE DRYER EXHAUST DETAIL INDICATES A VENT
 WITH BIRD SCREEN. PLEASE REMOVE THIS NOT AS THERE ARE
 NO SCREENS ALLOWED AT THE TERMINATION OF A DRYER
 EXHAUST. FBC RES M1502.3
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-01-06 Cont ID  
Sent By abelisle Date 2022-01-06 Time 20:02 Rev Time 0.00
Received By abelisle Date 2022-01-06 Time 18:22 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 16:19 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 16:19 Sent To  
Notes
2022-05-16 16:19:34SHINGLES NOA 18-0123.06

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2022-03-09 Cont ID  
Sent By jgomez Date 2022-03-08 Time 18:42 Rev Time 0.00
Received By jgomez Date 2022-03-08 Time 18:40 Sent To  
Notes
2022-03-09 10:39:26SHINGLES NOA 18-0123.06

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-05-18 Cont ID  
Sent By jgomez Date 2022-05-18 Time 09:28 Rev Time 0.00
Received By jgomez Date 2022-05-18 Time 09:27 Sent To  
Notes
2022-05-18 09:29:35SOIL TEST REPORT WITH EMBOSSED SEAL AND WET SIGNATURE.
 JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-05-16 Cont ID  
Sent By jgomez Date 2022-05-16 Time 16:21 Rev Time 0.00
Received By jgomez Date 2022-05-16 Time 16:19 Sent To  
Notes
2022-05-16 16:23:32SIGNATURE REVIEW:
  
 1- SOIL TEST REPORT SUBMITTED NEEDS ENGINEER'S ORIGINAL
 SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S. WHEN
 SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH DIGITAL
 SIGNATURE OR PROVIDE HARD COPY WITH ORIGINAL SEAL AND
 SIGNATURE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-08 Cont ID  
Sent By jgomez Date 2022-03-08 Time 18:29 Rev Time 0.00
Received By jgomez Date 2022-03-08 Time 18:24 Sent To  
Notes
2022-03-08 18:30:33SIGNATURE REVIEW:
  
 1- SOIL TEST REPORT SUBMITTED NEEDS ENGINEER'S ORIGINAL
 SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S. WHEN
 SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH DIGITAL
 SIGNATURE OR PROVIDE HARD COPY WITH ORIGINAL SEAL AND
 SIGNATURE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-04-08 Cont ID  
Sent By vbroglia Date 2022-04-08 Time 11:31 Rev Time 0.00
Received By vbroglia Date 2022-04-08 Time 11:31 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-02-01 Cont ID  
Sent By vbroglia Date 2022-01-13 Time 16:45 Rev Time 0.00
Received By vbroglia Date 2022-01-07 Time 16:45 Sent To  
Notes
2022-01-13 09:18:48 
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved