 |
Plan Review Details - Permit 21120835
Plan Review Stops For Permit 21120835 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2022-03-09 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2022-03-09 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-13 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-13 |
Time |
12:47 |
Sent To |
|
|
Notes |
2022-01-13 14:17:44 | ELECTRICAL PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE FLOOR PLANS FOR 1ST AND 2ND FLOORS. IDENTIFY | | LOCATION OF ITEMS 1 THRU 5 FROM ELECTRICAL NOTES ON | | PLAN PAGE A.04, PERMIT 21120382. | | EC C405.1 & R404.1; NEC 406.12 & E4002.14; NEC | | 210.8/210.12 & E3902; E3902.2. | | PROVIDE LOCATION OF EXISTING SERVICE, MAIN DISCONNECT | | AND PANEL. NEC 215.5; WPB FBC 107.2.1 | | PROVIDE LOCATION OF PROPOSED REPLACEMENT 225 AMP | | ELECTRICAL PANEL. E3601.6.2SERVICE DISCONNECT LOCATION. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE AN ELECTRICAL RISER DIAGRAHM. | | PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC | | 107.2.1 | | PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL LOADS. | | NEC 220; FBC RE E3602.2 | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
2 |
Status |
P |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2022-03-09 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2022-03-09 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-13 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-13 |
Time |
12:46 |
Sent To |
|
|
Notes |
2022-01-13 13:57:08 | ELECTRICAL PLAN REVIEW-LOW VOLTAGE | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | 2017 NEC | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE FLOOR PLANS FOR 1ST AND 2ND FLOORS. IDENTIFY | | LOCATION OF LOW VOLTAGE DEVICES. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2022-03-09 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2022-02-28 |
Time |
12:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-13 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-13 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2022-03-09 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2022-03-09 |
Time |
09:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-13 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-13 |
Time |
12:47 |
Sent To |
|
|
Notes |
2022-01-13 14:20:24 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | RE: ELECTRICAL RISER DIAGRAHM | | | | 1. THE ELECTRICAL CONTRACTOR OR DESIGNER OF RECORD | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON PLAN | | SHEETS UNDER THEIR AUTHORITY. | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, SECTION 107.2.1. | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | WITH SIGNATURE OF CONTRACTOR OR DESIGNER, AS | | APPLICABLE; USE THE REQUIRED NAMING CONVENTION FOR EACH | | DOCUMENT OR DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH | | CONTRACTORS/O/B SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |