Plan Review Details - Permit 21120818
Plan Review Stops For Permit 21120818
Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-01-19 Cont ID  
Sent By pleduc Date 2022-01-19 Time   Rev Time 0.00
Received By pleduc Date 2022-01-19 Time 14:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-11 Cont ID  
Sent By pleduc Date 2022-01-11 Time   Rev Time 0.00
Received By pleduc Date 2022-01-11 Time 12:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-12-22 Cont ID  
Sent By pleduc Date 2021-12-22 Time   Rev Time 0.00
Received By pleduc Date 2021-12-22 Time 10:55 Sent To  
Notes
2021-12-22 15:52:47THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF FIRE LINE UNDERGROUND
 WORK.
  
 FIRE LINE UNDERGROUND WORK, INCLUDING THE DDCV, SHALL
 BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP DRAWINGS.
  
 THIS PERMIT WILL NOT BE APPROVED FOR UNDERGROUND WORK.
  
 PLEASE REVIEW AND PROVIDE AN APPLICABLE NOTE OF
 ACKNOWLEDGMENT THAT A SPEARATE FIRE LINE UNDEGROUND
 PERMIT WILL BE SUBMITTED.
  
  
 1A) A SEPARATE WATER METER & TAP IS REQUIRED BY THE
 CITY'S UTILITY DEPARTMENT FOR FIRE SPRINKLER SYSTEMS,
 INCLUDING 13R.
  
 PLEASE CONTACT THAT DEPARTMENT FOR THEIR REQUIREMENTS
 FOR THE SEPARATE PERMIT(S).
  
  
 2) IT APPEARS THAT THIS OCCUPANCY MAY BE A NEW
 RESIDENTIAL BOARD & CARE FACILITY AS SUCH SHALL COMPLY
 WITH NFPA 101, CH 32.
  
 PER THAT CHAPTER :
  
 32.2.3.5.3.1 IN BUILDINGS FOUR OR FEWER STORIES IN
 HEIGHT AND NOT EXCEEDING
 60 FT (18.3 M) IN HEIGHT ABOVE GRADE PLANE, SYSTEMS IN
 ACCORDANCE
 WITH NFPA 13R SHALL BE PERMITTED. ALL HABITABLE AREAS,
 CLOSETS, ROOFED
 PORCHES, ROOFED DECKS, AND ROOFED BALCONIES SHALL BE
 SPRINKLERED
  
 THERE APPEARS TO BE CLOSETS WITHOUT FS PROTECTION AS
 WELL AS ROOFED BALCONIES.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC A
 DETAILED NARRATIVE AND FIRE CODE REFERENCES.
  
  
  
 3) IT APPEARS THAT THIS BUILDING MAY HAVE AN ATTIC OR A
 ROOM ON THE ROOF.
  
  
 PER THAT CHAPTER :
  
 32.2.3.5.7 ATTICS SHALL BE PROTECTED IN ACCORDANCE WITH
 32.2.3.5.7.1 OR
 32.2.3.5.7.2.
 32.2.3.5.7.1 WHERE AN AUTOMATIC SPRINKLER SYSTEM IS
 REQUIRED BY
 32.2.3.5, ATTICS USED FOR LIVING PURPOSES, STORAGE, OR
 FUEL-FIRED EQUIPMENT
 SHALL BE PROTECTED WITH AUTOMATIC SPRINKLERS THAT ARE
 PART OF THE REQUIRED,
 APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 9.7.1.1.
 32.2.3.5.7.2 WHERE AN AUTOMATIC SPRINKLER SYSTEM IS
 REQUIRED BY
 32.2.3.5, ATTICS NOT USED FOR LIVING PURPOSES, STORAGE,
 OR FUEL-FIRED EQUIPMENT
 SHALL MEET ONE OF THE FOLLOWING CRITERIA:
 (1) ATTICS SHALL BE PROTECTED THROUGHOUT BY A HEAT
 DETECTION SYSTEM
 ARRANGED TO ACTIVATE THE BUILDING FIRE ALARM SYSTEM IN
 ACCORDANCE
 WITH SECTION 9.6.
 (2) ATTICS SHALL BE PROTECTED WITH AUTOMATIC SPRINKLERS
 THAT ARE PART OF
 THE REQUIRED, APPROVED AUTOMATIC SPRINKLER SYSTEM IN
 ACCORDANCE
 WITH 9.7.1.1.
 (3) ATTICS SHALL BE OF NONCOMBUSTIBLE OR
 LIMITED-COMBUSTIBLE
 CONSTRUCTION.
 (4) ATTICS SHALL BE CONSTRUCTED OF
 FIRE-RETARDANT-TREATED WOOD IN ACCORDANCE
 WITH NFPA 703.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC A
 DETAILED NARRATIVE AND FIRE CODE REFERENCES.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-19 Cont ID  
Sent By rmcphers Date 2022-01-19 Time 14:50 Rev Time 0.00
Received By rmcphers Date 2022-01-19 Time 07:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-12 Cont ID  
Sent By rmcphers Date 2022-01-12 Time 09:30 Rev Time 0.00
Received By rmcphers Date 2022-01-10 Time 09:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-12-23 Time   Rev Time 0.00
Received By lmarchan Date 2021-12-20 Time 09:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-01-19 Cont ID  
Sent By rmcphers Date 2022-01-19 Time 14:31 Rev Time 0.00
Received By rmcphers Date 2022-01-19 Time 14:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-01-12 Cont ID  
Sent By rmcphers Date 2022-01-12 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2022-01-12 Time 09:26 Sent To  
Notes
2022-01-12 09:30:30SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS OR DOCUMENTS - FIRE SPRINKLER HYDRAULIC
 CALCULATIONS, FP-1, FP-2, FP-3 DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-12-23 Cont ID  
Sent By ccole Date 2021-12-23 Time 12:08 Rev Time 0.00
Received By ccole Date 2021-12-23 Time 12:04 Sent To  
Notes
2021-12-23 12:11:33DIGITAL SIGNATURE REVIEW
 PERMIT 21120818
 12/23/2021
  
 1) THE PLANS HAVE COPIED ENGINEER?S SEAL AND SIGNATURE
 THAT ARE NOT VERIFIABLE. PLEASE NOTE PLANS AND
 DOCUMENTS THAT ARE PREPARED BY A FL. LICENSED ENGINEER,
 WHICH ARE TRANSMITTED ELECTRONICALLY SHALL BEAR THE
 DIGITAL SEAL SIGNATURE OF THE ENGINEER OF RECORD- FL.
 STATUTE 471.025, AND SECTION 61G15-23.005 FAC. PLEASE
 SEE SIGNATURE FOR ADDITIONAL INFORMATION.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved