Plan Review Details - Permit 21120763
Plan Review Stops For Permit 21120763
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-23 Cont ID  
Sent By cpuell Date 2022-02-23 Time 11:00 Rev Time 0.00
Received By cpuell Date 2022-02-23 Time 11:00 Sent To  
Notes
2022-02-23 11:01:09PLEASE CONTACT [email protected], TO BE ASSIGNED A GENERIC
 PROPERTY CONTROL NUMBER FOR AT&T, ALSO PLEASE EMAIL A
 SITE PLAN SHOWING THE EXACT LOCATION OF THE WHERE THE
 WORK IS TO BE DONE. IN THE FUTURE PLEASE MAKE SURE THAT
 YOU COORDINATE WITH [email protected] OR CALL 561-805-6659
 BEFORE APPLYING FOR A PERMIT TO BE ISSUED AN @ ADDRESS.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-06-27 Cont ID  
Sent By sberglun Date 2022-06-27 Time 13:50 Rev Time 0.00
Received By sberglun Date 2022-06-27 Time 13:48 Sent To  
Notes
2022-06-27 13:50:231) PER ZONING COMMENT #3, PLEASE SHOW HOW UNDERGROUND
 POWER WILL BE SERVING THE POLE FOR THE CITY TO RECIEW.
 A CROSS SECTION WILL BE REQUIRED SO STAFF CAN REVIEW
 THE IMPACT TO UNDERGROUND INFRASTRUCTURE.
  
 SUZANNE BERGLUND
 [email protected]
 561-494-1075

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-28 Cont ID  
Sent By jgomez Date 2022-06-28 Time 15:06 Rev Time 0.00
Received By jgomez Date 2021-12-15 Time 14:19 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-06-28 Cont ID  
Sent By jgomez Date 2022-06-28 Time 15:06 Rev Time 0.00
Received By jgomez Date 2022-06-28 Time 15:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-15 Cont ID  
Sent By eschneid Date 2022-03-15 Time 17:02 Rev Time 0.25
Received By eschneid Date 2022-02-23 Time 08:22 Sent To  
Notes
2022-03-15 17:03:23INSUFFICIENT
  
 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED
 SURVEYOR, SHOWS THE POLE LOCATION, THE RIGHT-OF-WAY
 LINE, AND THE UNDERGROUND ELECTRIC TO THE POLE SO THAT
 STAFF CAN VERIFY THAT THE UNDERGROUND ELECTRIC AND ANY
 REQUIRED BORE PITS AND HANDHOLES ARE WITHIN THE
 RIGHT-OF-WAY AND WHICH JURISDICTION'S RIGHT-OF-WAY THEY
 ARE IN. NOTE: AS PROVIDED IN PREVIOUS CORRESPONDENCE,
 THE CITY HAS VERIFIED THAT THE POLE LOCATION IS WITHIN
 PALM BEACH COUNTY'S RIGHT-OF-WAY. THE SURVEY MUST ALSO
 INCLUDE THE HEIGHT OF THE PROPOSED POLE AND THE HEIGHT
 OF THE UTILITY POLE WITHIN THE RIGHT-OF-WAY THAT IS
 BEING USED TO ESTABLISH THE HEIGHT OF THE PROPOSED
 WIRELESS COMMUNICATION FACILITY POLE.
  
 2) PROVIDE A COPY OF THE PALM BEACH COUNTY RIGHT-OF-WAY
 APPROVAL FOR THE PROPOSED WIRELESS COMMUNICATION
 FACILITY IN THEIR RIGHT-OF-WAY
  
 3) IF THE SURVEY SHOWS THE UNDERGROUND POWER USES CITY
 RIGHTS-OF-WAY, THEN THE CITY REVIEWS THAT PORTION OF
 THE PROJECT AS PART OF THE COMMUNICATIONS FACILITY
 PLACEMENT PERMIT IN CITY RIGHTS-OF-WAY APPLICATION (WCF
 ROW). YOUR CURRENT APPLICATION NOTES THAT THE EXACT
 POWER CONDUIT RUN WILL BE AT THE TIME OF CONSTRUCTION,
 WHICH DOES NOT MEET THE CITY'S ELECTRIC PERMITTING
 REQUIREMENTS. THE UNDERGROUND POWER MUST BE SHOWN ON
 THE ELECTRIC PERMIT FOR THE POLE. IF THIS IS SHOWN TO
 BE IN A CITY RIGHT-OF-WAY, THEN YOU ALSO NEED TO UPDATE
 THIS WCF ROW APPLICATION. IF NO FACILITIES ARE WITHIN
 CITY RIGHTS-OF-WAY, THE CITY WILL CLOSE THIS WCF ROW
 APPLICATION AND ONLY AN ELECTRIC PERMIT IS REQUIRED.
  
 4) PLEASE REMEMBER THAT THE ELECTRIC PERMIT MUST STILL
 INCLUDE THE SURVEY FROM A FLORIDA REGISTERED SURVEYOR,
 WHICH INCLUDES THE HEIGHT OF NEARBY UTILITY POLES.
  
 5) NOTE: ANY UNDERGROUND POWER THAT IS WITHIN CITY
 RIGHTS-OF-WAY REQUIRES A CROSS SECTION SO STAFF CAN
 REVIEW THE IMPACT ON UNDERGROUND UTILITIES AND TREE
 ROOT SYSTEMS.
  
 6) THE POLE STYLE MEETS CITY REQUIREMENTS AND SHALL
 MATCH THE METAL POLE INSTALLED EAST OF THIS LOCATION ON
 PALM BEACH LAKES BOULEVARD.
  
 ADDITIONAL COMMENTS MAY BE PROVIDED UPON SUBMITTAL OF
 THE REQUIRED INFORMATION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  