Plan Review Stops For Permit 21120302 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-12-07 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-12-07 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-11-30 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-11-30 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2022-09-08 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-09-08 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-09-08 |
Time |
09:05 |
Sent To |
|
|
Notes |
2022-09-08 09:17:30 | 1) SHEET B-1 SURVEY INCORRECTLY IDENTIFIES A SANITARY | | SEWER MANHOLE AND SHOWS AN UNDERGROUND SANITARY SEWER | | LINE GOING NORTH. THIS IS A AIR RELEASE VALVE FOR A 30" | | FORCE MAIN THAT RUNS NORTH AND SOUTH OF THIS STRUCTURE. | | IF THIS SURVEY IS ONLY ABOVE GROUND IMPROVEMENTS, | | PLEASE DO NOT INCORRECTLY SHOW UNDERGROUND | | IMPROVEMENTS. IF THE SURVEY SHOWS UNDERGROUND | | IMPROVEMENTS, ALL UNDERGOUND IMPROVEMENTS MUST BE SHOWN | | CORRECTLY. | | | | 2) PLEASE SHOW OFFSETS OF A 5' MINIMUM DISTANCE FROM | | THE OUTER EDGE OF THE POLE AND FOUNDATION TO THE OUTER | | EDGE OF THE CITY'S 24" WATERMAIN. THIS DISTANCE MUST BE | | MAINTAINED AS THIS IS A MAJOR WATER TRANSMISSION MAIN | | SERVING THE NORTH END OF THE CITY. SOFT DIGS MUST BE | | DONE PRIOR TO SETTING THE POLE TO VERIFY THE EXACT | | LOCATION OF THE CITY'S 24" WATERMAIN. | | | | 3) PLEASE USE EXTREME CAUTION WHEN BORING IN THIS AREA | | AND MINIMUM DISTANCES TO CITY UTILITIES MUST BE | | MAINTAINED. | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
gpatrie |
Date |
2022-06-23 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-06-23 |
Time |
16:23 |
Sent To |
|
|
Notes |
2022-06-23 16:24:05 | 1) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS. | | INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE | | MATERIAL, AND DESCRIPTION ON THE SITE PLAN. CONTACT | | JANICE TARBILL, [email protected] FOR AS-BUILT | | INFORMATION. INCLUDE AS-BUILT INFORMATION IN YOUR | | RESUBMITTAL. | | 2) PROVIDE PROFILE FOR PROPOSED UNDERGROUND ELECTRIC | | SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | REQUIRED PER CITY STANDARD. | | | | SUZANNE BERGLUND | | [email protected] | | 561-494-1075 | | | 2022-05-23 14:47:31 | CELL TOWER LOCATION APPROVED. | | ADDRESS ERIC SCHNEIDER COMMENTS. | | | | CONTACT [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-12-01 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-12-01 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-10-06 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-09-21 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-18 |
Time |
06:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-08-02 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-06-23 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-05-24 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-07 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-09-21 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-08-02 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-08-02 |
Time |
11:18 |
Sent To |
|
|
Notes |
2022-08-02 10:50:41 | 1) THE DIGITAL SIGNATURE OF ALEXANDER ABERNATHY, PE IS | | SELF-CERTIFIED. THE FLORIDA BOARD OF PROFESSIONAL | | ENGINEERS REQUIRES ENGINEERS TO USE AN APPROVED THIRD | | PARTY AGENCY TO CERTIFY THEIR SIGNATURES. FS 471 & FAC | | 61G15 | | | | 2) THE SHEETS THAT WERE SUBMITTED FROM JACOB GORALSKI, | | PE ARE COPIES OF SIGNED AND SEALED PAPER DOCUMENTS. | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & | | FAC 61G15 | | | | 3) SEE PREVIOUS SIGNATURE REVIEW COMMENTS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-17 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-12-17 |
Time |
15:47 |
Sent To |
|
|
Notes |
2021-12-17 15:47:48 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | 12/6/2021 | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | EMAIL AS AN ATTACHMENT. | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | APPLICATION TO [email protected]. THEY WILL | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | UPLOAD YOUR PLANS. | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | SIGNATURE FOLDER. | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-12-14 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-11-29 |
Time |
16:32 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-11-29 |
Time |
13:03 |
Sent To |
|
|
Notes |
2022-11-29 16:33:14 | THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-09-21 |
Time |
11:28 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-09-20 |
Time |
17:05 |
Sent To |
|
|
Notes |
2022-09-21 11:28:59 | INSUFFICIENT | | | | 1) THE LATITUDE AND LONGITUDE COORDINATES FOR THE FINAL | | POLE LOCATION HAVE NOT BEEN UPDATED ON THE SITE PLAN | | AND SURVEY. PLEASE PROVIDE THE CORRECT COORDINATES. | | | | 2) THE NEW SURVEY THAT CORRECTLY CALLS OUT THE | | 28-FOOT-TALL POLE WAS NOT UPLOADED. | | | | 3) THE RELOCATED HANDHOLE BY THE POWER DRAW POLE ON | | SHEET P-1 CORRECTLY ADDRESSES THE LAST SET OF COMMENTS | | (NOTE: SIDEWALK NEEDS TO BE RESTORED TO CITY STANDARDS | | AT THIS LOCATION). THE UPLOAD FOR THIS SHEET LOCATION | | INCLUDED THE ENTIRE JOB PACKAGE. PLEASE ONLY UPLOAD | | SHEET P-1 UNDER THE P-1 TAB. ADDITIONALLY, IT APPEARS | | THAT EVERY SHEET IN THE PACKAGE HAS A NEW "LATEST | | REVISION DATE" AND A NEW ENGINEER OF RECORD SIGNING. | | PLEASE ENSURE THAT THE MOST RECENT VERSION OF EACH | | SHEET IS UPLOADED. THIS DID NOT OCCUR IN ALL INSTANCES. | | | | 4) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-08-01 |
Time |
13:30 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-08-01 |
Time |
11:15 |
Sent To |
|
|
Notes |
2022-08-01 13:31:10 | INSUFFICIENT | | | | 1) REPEAT COMMENT: THE LOCATION OF THE HANDHOLE AND THE | | INSTALL EXCAVATION SHOWN ADJACENT TO THE POLE SUPPLYING | | POWER WILL DAMAGE THE ROOT SYSTEM OF THE EXISTING LARGE | | STREET TREE IF INSTALLED IN THE LOCATION SHOWN ON SHEET | | P-1. THE HANDHOLE MAY NOT BE INSTALLED AT THIS | | LOCATION. *** THE EXCAVATION PIT CONTINUES TO BE SHOWN | | LESS THEN 5 FEET FROM THE TREE, WHICH IS TOO CLOSE. IT | | NEEDS TO BE AT LEAST 10 FEET AWAY, ESPECIALLY GIVEN THE | | SIZE OF THE TREE. STAFF SUGGESTS THAT THE HANDHOLE BE | | INSTALLED UNDER THE SIDEWALK SO THAT IT, AND THE | | EXCAVATION, ARE FURTHER AWAY FROM THE TREE AND IN AN | | AREA THAT TYPICALLY SEES LESS ROOT ZONE EXPANSION. | | | | 2) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP | | 7042 TRAFFIC GREY A. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-03-30 |
|
|
Cont ID |
|
Sent By |
eshneide |
Date |
2022-03-30 |
Time |
15:47 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-03-30 |
Time |
15:47 |
Sent To |
|
|
Notes |
2022-03-30 15:48:15 | INSUFFICIENT | | | | 1) THE SURVEY AND ENGINEERING PLANS FAIL TO SHOW TWO | | PALM TREES THAT ARE LOCATED WITHIN THE BULB OUT WHERE | | THE POLE IS PROPOSED. PLEASE SHOW THE TREES IN THEIR | | ACCURATE LOCATIONS SO THAT STAFF CAN VERIFY THAT THERE | | IS NO CONFLICT WITH THE PROPOSED POLE. | | | | 2) THE CITY CODE REQUIRES THAT POLES SHALL BE LOCATED | | SO AS TO ALIGN WITH EXISTING POLES IN THE RIGHT-OF-WAY | | AND HAVE EQUAL SETBACK DISTANCES WITH EXISTING POLES | | FROM THE CURBLINE OF THE RIGHT-OF-WAY. THE PROPOSED | | POLE IS NOT SHOWN IN LINE WITH THE EXISTING LIGHT POLES | | ALONG TAMARIND AVENUE IN THIS LOCATION. THE EXISTING | | LIGHT POLES ARE LOCATED ADJACENT TO THE SIDEWALK (A | | GOOGLE STREETVIEW SCREENSHOT HAS BEEN PROVIDED TO | | CHRISTINA WARR). PLEASE ADJUST THE PROPOSED POLE | | LOCATION ACCORDINGLY. | | | | 3) THE ADJACENT LOT IS IN THE APPROVAL PROCESS FOR A | | RESIDENTIAL BUILDING. IN ORDER TO COMPLY WITH THE CITY | | CODE REQUIREMENT THAT DOES NOT PERMIT WIRELESS | | FACILITIES TO BE PLACED IN FRONT OF A RESIDENTIAL | | STRUCTURE, THE PROPOSED POLE NEEDS TO BE MOVED SOUTH | | WITHIN THE BULB OUT. STAFF HAS PROVIDED CHRISTINA WARR | | WITH THE SITE PLAN SHOWING THE SETBACK OF THE RESIDENCE | | FROM THE BACK OF THE STATE STREET SIDEWALK SO THAT THE | | POLE LOCATION CAN BE ADJUSTED ACCORDINGLY. | | 4) THE BORE PIT AND HANDHOLE NOTES ON SHEET P-1 STATE | | THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, THESE ARE | | LOCATED ONLY WITHIN THE PARKWAY WHICH WILL NEED | | RESTORATION. PLEASE UPDATE THE NOTATIONS ACCORDINGLY. | | | | 5) THE LOCATION OF THE HANDHOLE AND THE INSTALL | | EXCAVATION SHOWN ADJACENT TO THE POLE SUPPLYING POWER | | WILL DAMAGE THE ROOT SYSTEM OF THE EXISTING LARGE | | STREET TREE IF INSTALLED IN THE LOCATION SHOWN ON SHEET | | P-1. THE HANDHOLE MAY NOT BE INSTALLED AT THIS | | LOCATION. | | | | 6) THE POLE HEIGHT SHOWN ON SHEET C-3 LISTS THE HEIGHT | | TO THE TOP OF THE ANTENNA AS 28 FEET ABOVE GRADE; | | HOWEVER, THE SITE PLAN AND SURVEY CALL OUT A POLE 38 | | FEET ABOVE GRADE LEVEL. ALL SHEETS MUST SHOW | | CONSISTENT, ACCURATE INFORMATION. NOTE: THE 38-FOOT | | HEIGHT IS CONSISTENT WITH ONE OF THE NEARBY POWER | | POLES. | | | | 7) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC | | WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH | | EXISTING UTILITIES AND TREE ROOTS. | | | | 8) THE PLANS SHOW THE COM LINES WITHIN 2-FEET OF THE | | BORE PIT(S). IN ORDER TO VERIFY THAT THE INSTALLATION | | WILL NOT INTERFERE WITH THE EXISTING FACILITIES, | | PROVIDE A PUBLIC UTILITY LETTER OF NO OBJECTION FROM | | THE COM PROVIDER(S), MOST LIKELY AT&T OR COMCAST. | | | | 9) THE POLE STYLE MEETS CITY REQUIREMENTS. THE POLE | | COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP 7042 TRAFFIC | | GREY A. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|