Plan Review Details - Permit 21120284
Plan Review Stops For Permit 21120284 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-12-07 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-12-07 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2023-05-02 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2023-05-02 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-06-23 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-06-23 |
Time |
17:04 |
Sent To |
|
|
Notes |
2022-06-23 17:05:33 | 1) PROPOSED ELECTRIC AND POLE LOCATION DOES NOT APPEAR | | TO BE IN CONFLICT WITH CITY UTILITIES HOWEVER CITY | | UTILITIES ARE SHOWN INCORRECTLY ON PLANS. INCLUDE CITY | | UNDERGROUND UTILITIY PIPE SIZE, PIPE MATERIAL, AND | | DESCRIPTION ON THE SITE PLAN. CONTACT JANICE TARBILL, | | [email protected] FOR AS-BUILT INFORMATION. INCLUDE | | AS-BUILT INFORMATION IN YOUR RESUBMITTAL. | | 2) PROVIDE PROFILE FOR PROPOSED UNDERGROUND ELECTRIC | | SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | REQUIRED PER CITY STANDARD. | | | | SUZANNE BERGLUND | | [email protected] | | 561-494-1075 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
avolcy |
Date |
2023-05-16 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
avolcy |
Date |
2023-05-16 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-07 |
Time |
12:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-17 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-12-17 |
Time |
16:34 |
Sent To |
|
|
Notes |
2021-12-17 16:34:48 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | 12/6/2021 | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | EMAIL AS AN ATTACHMENT. | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | APPLICATION TO [email protected]. THEY WILL | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | UPLOAD YOUR PLANS. | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | SIGNATURE FOLDER. | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
avolcy |
Date |
2023-05-16 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
avolcy |
Date |
2023-05-16 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-01-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-01-05 |
Time |
11:33 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-01-05 |
Time |
09:22 |
Sent To |
|
|
Notes |
2022-01-05 11:50:21 | FAILED | | | | 1) THE SITE PLAN NEEDS TO SHOW THE EDGE OF THE EXISTING | | HEDGE AREA AND THE LOCATION OF THE SERVICE GROUND ROD | | SO THAT STAFF CAN VERIFY THAT THERE ARE NO CONFLICTS. | | | | 2) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | THE POLE COLOR IS TO BE STEEL/GREY SIMILAR TO AT&T POLE | | AT BELVEDERE AND SOUTH DIXIE. | | | | 3) THE HANDHOLE AND BORE PIT NOTES ON SHEET P-1 STATE | | THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, BOTH | | LOCATIONS ARE IN A LANDSCAPED AREA AND DO NOT APPEAR TO | | AFFECT THE SIDEWALK. | | | | 4) THE CROSS SECTION OF THE UNDERGROUND ELECTRIC | | INSTALLATION IS REQUIRED TO BE PROVIDED AND INCLUDE THE | | DEPTH OF THE UNDERGROUND INSTALLATION. STAFF MUST | | VERIFY THAT THE ROOT SYSTEM OF THE EXISTING TREE TO THE | | EAST OF THE HANDHOLE IS NOT IMPACTED. VERIFICATION THAT | | THE GAS LINE IS NOT IMPACTED IS ALSO REQUIRED (ALSO SEE | | COMMENT #5). | | | | 5) THE PLANS SHOW THE GAS LINE WITHIN 5-FEET OF THE | | EXCAVATION FOR THE HANDHOLE. IN ORDER TO VERIFY THAT | | THE INSTALLATION WILL NOT INTERFERE WITH THE EXISTING | | FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF NO | | OBJECTION FROM FPU REGARDING THE INSTALLATION. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | | | |
|
|
|