Plan Review Stops For Permit 21120282 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-12-07 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-12-07 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-08-02 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-08-02 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
gpatrie |
Date |
2022-06-23 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-06-23 |
Time |
16:35 |
Sent To |
|
|
Notes |
2022-06-23 16:36:06 | 1) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS. | | INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE | | MATERIAL, AND DESCRIPTION ON THE SITE PLAN. CONTACT | | JANICE TARBILL, [email protected] FOR AS-BUILT | | INFORMATION. INCLUDE AS-BUILT INFORMATION IN YOUR | | RESUBMITTAL. | | 2) PROVIDE PROFILE FOR PROPOSED UNDERGROUND ELECTRIC | | SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | REQUIRED PER CITY STANDARD. | | | | SUZANNE BERGLUND | | [email protected] | | 561-494-1075 | | | 2022-05-24 10:57:06 | POLE LOCATION IS ACCPTABLE. | | ADDRESS ZONING COMMENTS. | | | | CONTACT: [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-04 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-20 |
Time |
06:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-07-19 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-06-23 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-17 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-10 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-25 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-05-25 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-07 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-04 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-04 |
Time |
19:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-17 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-17 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-17 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-12-17 |
Time |
17:31 |
Sent To |
|
|
Notes |
2021-12-17 17:31:17 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | 12/6/2021 | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | EMAIL AS AN ATTACHMENT. | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | APPLICATION TO [email protected]. THEY WILL | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | UPLOAD YOUR PLANS. | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | SIGNATURE FOLDER. | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-08-03 |
Time |
10:44 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-08-03 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-07-19 |
Time |
14:53 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-07-19 |
Time |
11:20 |
Sent To |
|
|
Notes |
2022-07-19 14:54:04 | MEETS ZONING ***** FAIL STATUS SO THAT THIS PERMIT IS | | VERIFIED BY ZONING AFTER NEXT ENGINEERING REVIEW ***** | | | | THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. THE | | POLE COLOR AT THIS LOCATION IS RAL/RAYCAP 7042 TRAFFIC | | GREY A. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-06-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2022-06-15 |
Time |
15:55 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-06-15 |
Time |
15:01 |
Sent To |
|
|
Notes |
2022-06-15 15:55:42 | INSUFFICIENT | | | | 1) THE PLANS SHOW ONE OF THE BORE PITS AND THE POLE | | INSTALL WITHIN 4 FEET OF A GAS LINE. IN ORDER TO VERIFY | | THAT THE INSTALLATION WILL NOT INTERFERE WITH THE | | EXISTING FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF | | NO OBJECTION FROM FPU REGARDING THE INSTALLATION. | | | | 2) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | THE POLE COLOR AT THIS LOCATION IS CORRECTLY SHOWN AS | | RAL/RAYCAP 7042 TRAFFIC GREY A. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
Sent By |
eshneide |
Date |
2022-03-09 |
Time |
16:34 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2022-01-28 |
Time |
13:45 |
Sent To |
|
|
Notes |
2022-03-09 16:34:25 | INSUFFICIENT | | | | 1) WHILE A SIDEWALK DOES NOT CURRENTLY EXIST AT THIS | | PORTION OF 43RD STREET, IF A SIDEWALK IS INSTALLED, IT | | WILL BE LOCATED AT THE RIGHT-OF-WAY LINE. IN ORDER THAT | | THE POLE DOES NOT CONFLICT WITH A FUTURE SIDEWALK, THE | | PLANS MUST CLEARLY SHOW THAT THE ENTIRE POLE, INCLUDING | | THE MOUNTING BASE, IS LOCATED AT LEAST FIVE FEET FROM | | THE RIGHT-OF-WAY LINE. THE SETBACK DIMENSIONS THAT HAVE | | BEEN PROVIDED SEEM TO BE TO THE POLE AND DO NOT INCLUDE | | THE MOUNTING BASE, WHICH IS SHOWN ON SHEET C-4 AS | | LARGER THAN THE POLE (NO DIMENSION IS PROVIDED). | | PROVIDE CLEAR EVIDENCE OF A FIVE-FOOT CLEAR SETBACK | | FROM THE EDGE OF THE RIGHT-OF-WAY. NOTE THERE IS | | SUFFICIENT ROOM BETWEEN THE POLE AND THE CURB TO | | ACCOMMODATE THE SHIFT. | | | | 2) THE BORE PIT AND HANDHOLE NOTES ON SHEET P-1 STATE | | THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, THESE ARE | | LOCATED ONLY WITHIN THE PARKWAY WHICH WILL NEED | | RESTORATION. PLEASE UPDATE THE NOTATIONS ACCORDINGLY. | | | | 3) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC | | WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH | | EXISTING UTILITIES AND TREE ROOTS. | | | | 4) THE PLANS SHOW ONE OF THE BORE PITS AND THE POLE | | INSTALL WITHIN 4 FEET OF A GAS LINE. IN ORDER TO VERIFY | | THAT THE INSTALLATION WILL NOT INTERFERE WITH THE | | EXISTING FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF | | NO OBJECTION FROM FPU REGARDING THE INSTALLATION. | | | | 5) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP | | 7042 TRAFFIC GREY A. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | |
|
|