Plan Review Stops For Permit 21120281 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-12-07 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-12-07 |
Time |
16:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2023-02-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2023-02-17 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
sberglun |
Date |
2022-06-23 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
sberglun |
Date |
2022-06-23 |
Time |
15:13 |
Sent To |
|
|
Notes |
2022-06-23 15:23:56 | 1) THE CITY HAS AN EXISTING 24" WATER MAIN, A 20" WATER | | MAIN AND A 30" FORCE MAIN ALONG THIS SECTION OF | | TAMARIND AVENUE. SHOW ALL EXISTING CITY UTILITIES ON | | PLAN. PLEASE CONTACT [email protected] FOR AS-BUILT | | PLANS AND INCLUDE THEM WITH YOUR NEXT SUBMITTAL. | | 2) PLEASE PROVIDE PROFILE FOR PROPOSED UNDERGROUND | | ELECTRIC SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | REQUIRED PER CITY STANDARD. | | | | SUZANNE BERGLUND | | [email protected] | | 561-494-1075 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-02-17 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-02-17 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-11 |
Time |
06:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-01-10 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-01-09 |
Time |
07:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-12-07 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2021-12-17 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2021-12-17 |
Time |
17:30 |
Sent To |
|
|
Notes |
2021-12-17 17:30:50 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | 12/6/2021 | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | EMAIL AS AN ATTACHMENT. | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | APPLICATION TO [email protected]. THEY WILL | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | UPLOAD YOUR PLANS. | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | SIGNATURE FOLDER. | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2023-02-21 |
Time |
15:35 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2023-02-21 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-02-01 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2023-02-01 |
Time |
18:00 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2023-02-01 |
Time |
17:23 |
Sent To |
|
|
Notes |
2023-02-01 18:00:55 | INSUFFICIENT | | | | 1) THE POLE STYLE, COLOR AND HEIGHT MEET CITY | | REQUIREMENTS. | | | | 2) THE PLANS SHOW ONE OF THE BORE PITS BEING DUG AND | | THE POLE FOUNDATION BEING INSTALLED ADJACENT TO AN | | UNDERGROUND ELECTRIC LINE. IN ORDER TO VERIFY THAT THE | | INSTALLATION WILL NOT INTERFERE WITH THE EXISTING | | FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF NO | | OBJECTION FROM FPL REGARDING THE INSTALLATION. | | | | CONTACT ERIC SCHNEIDER @ 561-822-1446 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-01-28 |
|
|
Cont ID |
|
Sent By |
eshneide |
Date |
2022-01-28 |
Time |
10:49 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2022-01-28 |
Time |
10:49 |
Sent To |
|
|
Notes |
2022-01-28 11:55:58 | FAILED | | | | 1) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | | | 2) THE HANDHOLE AND BORE PIT NOTES ON SHEET P-1 STATE | | THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, THESE ARE | | IN LANDSCAPED AREAS AND NOT OVERLAPPING WITH A | | SIDEWALK. PLEASE UPDATE THE NOTATIONS ACCORDINGLY. | | | | 3) THE PLANS SHOW ONE OF THE BORE PITS BEING DUG | | ADJACENT TO A GAS LINE AND IN CONFLICT WITH AN | | UNDERGROUND ELECTRIC LINE. IN ORDER TO VERIFY THAT THE | | INSTALLATION WILL NOT INTERFERE WITH THE EXISTING | | FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF NO | | OBJECTION FROM FPU AND FPL REGARDING THE INSTALLATION. | | | | 4) PROVIDE CROSS SECTIONS OF THE UNDERGROUND ELECTRIC | | FOR THE FULL LENGTH OF THE INSTALLATION. THE | | UNDERGROUND ELECTRIC MUST BE CLEARLY SHOWN AVOIDING THE | | UNDERGROUND INFRASTRUCTURE AND ANY TREE ROOT SYSTEMS | | THAT IT CROSSES (EX: WATER LINE). | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | | | |
|
|