Plan Review Stops For Permit 21120113 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-24 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-24 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-20 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-20 |
Time |
11:33 |
Sent To |
|
|
Notes |
2022-01-20 12:40:32 | BUILDING PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE COVER SHEETS FOR MASONITE DOOR PRODUCT | | APPROVAL. | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | VERSION, AND STATUS, FBC R 301. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 2. FL 22513-R2 FOR EXT. STEEL DOORS HAS EXPIRED. | | PROVIDE A VALID PRODUCT APPROVAL PER FBC 2020 7TH ED. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 3. PROVIDE A PRODUCT APPROVAL FOR WINDOW MULLIONS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-24 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-24 |
Time |
11:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-01-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-01-10 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-01-10 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-01-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-01-05 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-01-05 |
Time |
14:55 |
Sent To |
|
|
Notes |
2022-01-05 15:03:56 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) NO SMOKE ALARMS SHOWN FBC R314,315 | | | | 2) NO PANEL SCHEDULE SHOWN 215.5 | | | | 3) NO OUTLET AT BACK OF UNIT 210.52 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-24 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-18 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-01-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-20 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2021-12-03 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-02-24 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-02-24 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-12-06 |
Time |
07:03 |
Rev Time |
|
Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2021-12-06 07:03:39 | 1ST REVIEW FBC-2020 MECHANICAL | | PERMIT-21120113 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE | | FBC M- FLORIDA MECHANICAL CODE | | FBC EC- FLORIDA ENERGY CONSERVATION | | FBC FG- FLORIDA FUEL GAS | | FBC EX- FLORIDA EXISTING BUILDING CODE | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) OUR RECORDS INDICATE THERE WAS NEVER A PERMITTED | | MECHANICAL SYSTEM INSTALLED AT THIS LOCATION. PLEASE | | SHOW PROOF THAT THERE WAS A PERMITTED MECHANICAL SYSTEM | | INSTALLED OR WE MUST CONSIDER THIS A FIRST TIME | | INSTALLATION. THIS WOULD MEAN THAT YOU MUST PROVIDE | | ENERGY CALCULATIONS, MECHANICAL EQUIPMENT SIZING | | CALCULATIONS AND A MECHANICAL DRAWING SHOWING ALL | | MECHANICAL WORK BEING COMPLETED UNDER THIS PERMIT. FBC | | 107.2.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2021-12-05 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-12-05 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-12-05 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-24 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2021-12-03 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2021-12-03 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2021-12-03 |
Time |
10:43 |
Sent To |
|
|
Notes |
2021-12-03 10:43:41 | OWNER BUILDER/CONTRACTOR DRAWINGS SIGNATURE NOT | | REQUIRED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2021-12-27 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2021-12-27 |
Time |
|
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2021-12-27 |
Time |
16:49 |
Sent To |
|
|
Notes |
|
|