Plan Review Details - Permit 21120100
Plan Review Stops For Permit 21120100 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-03-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-03-16 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-03-16 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-18 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-01-18 |
Time |
08:59 |
Sent To |
|
|
Notes |
2022-01-18 10:03:53 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, THE MARKED UP TABLE ON SHEET 13 OF 17 | | FOR THE ACCORDIANS (P.A. #FL16893 R6) NEEDS TO BE | | CORRECTED AS THERE APPEARS TO BE MISTAKES FOR THE | | FASTENER TYPE BEING USED. | | THE WPB SCHEDULE INDICATES (OPENINGS #1 & 5) THAT DUE | | TO A WOOD SUBSTRATE, THE FASTENERS ARE TO BE WOOD | | ANCHORS. THE INDICATED ANCHORS WITHIN THE PRODUCT | | APPROVAL ARE FOR CONCRETE. | | THE MISTAKE APPEARS TO BE BETWEEN MOUNT TYPE AND | | FASTENER TYPE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-03-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-03-16 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-02-11 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-01-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-01-18 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-12-02 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-12-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2021-12-02 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2021-12-02 |
Time |
15:40 |
Sent To |
|
|
Notes |
2021-12-02 15:42:55 | SIGNED AND SEALED DESIGN WIND LOADS CHART SENT TO | | STORAGE |
|
|
|