Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-11-23 Cont ID  
Sent By cpuell Date 2021-11-23 Time 14:20 Rev Time 0.00
Received By cpuell Date 2021-11-23 Time 14:20 Sent To  
Notes
2021-11-23 14:21:17WORK TO BE DONE ON THE EAST BUILDING ONLY, GIVEN THE
 ADDRESS OF 3715 S DIXIE HWY # 1
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-11-19 Cont ID  
Sent By cpuell Date 2021-11-19 Time 12:07 Rev Time 0.00
Received By cpuell Date 2021-11-19 Time 12:07 Sent To  
Notes
2021-11-19 12:14:08WHICH BUILDING IS THE WORK TO BE DONE ON, NORTH OR
 SOUTH? THE SOUTH BUILDING HAS A HALF ADDRESS WHICH WILL
 NEED TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS THE
 HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-01 Cont ID  
Sent By jbrooks Date 2021-12-01 Time 09:03 Rev Time 0.00
Received By jbrooks Date 2021-12-01 Time 07:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-19 Cont ID  
Sent By jbrooks Date 2021-11-19 Time 11:11 Rev Time 0.00
Received By jbrooks Date 2021-11-19 Time 07:44 Sent To  
Notes
2021-11-19 11:11:31JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL10497-R8 SELECTED SYSTEM NO. W-155 DO NOT
 MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN
 PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM
 NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE
 SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR
 ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 2. FBC EB 706.6 PROVIDE A FLASHING DETAIL FOR THE
 EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL
 HEIGHT(S).
 3. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF
 DRAINAGE PLAN THAT COMPLIES WITH SECTION 1503 OF THE
 2020 FBC-BUILDING AND CHAPTER 11 OF THE 2020
 FBC-PLUMBING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-01 Cont ID  
Sent By jbrooks Date 2021-12-01 Time 09:03 Rev Time 0.00
Received By jbrooks Date 2021-11-30 Time 07:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-19 Cont ID  
Sent By cpuell Date 2021-11-19 Time 12:14 Rev Time 0.00
Received By cpuell Date 2021-11-18 Time 16:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-11-19 Cont ID  
Sent By jbrooks Date 2021-11-19 Time 11:11 Rev Time 0.00
Received By jbrooks Date 2021-11-19 Time 07:44 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved