Plan Review Stops For Permit 21110547 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-14 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-14 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-21 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-21 |
Time |
16:26 |
Sent To |
|
|
Notes |
2021-12-21 16:27:58 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-03-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-02 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-02 |
Time |
11:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-14 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-14 |
Time |
10:19 |
Sent To |
|
|
Notes |
2022-02-14 10:26:51 | RENOVATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | 1) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE ARCHITECT OF RECORD (WILLIAM TRACY) FBC | | WPB 107.3.4 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-21 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-21 |
Time |
16:28 |
Sent To |
|
|
Notes |
2021-12-21 16:43:07 | ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE OCCUPANCY CLASSIFICATION FOR THE NEW | | SPACE - FBC 508.2.1 | | | | 2) BUILDING CONSTRUCTION TYPE IS SHOWN ON THE DRAWINGS | | AS IIB - PLEASE SHOW THE PLYWOOD ADDED TO THE WALLS AS | | "FIRE RETARDANT" PER FBC 603.1 | | | | 3) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE NEW EXTERIOR DOORS - ALL | | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE DESIGNER OF RECORD (ARCHITECT OR | | ENGINEER) FBC WPB 107.3.4 | | | | 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE REAR TOILET | | GRAB BAR DIMENSIONS FROM THE CENTER OF THE TOILET PER | | FBC A 604.5.2 | | | | 5) ACCESSIBLE RESTROOM - PLEASE SHOW THE DOOR | | MANEUVERING SPACE TO EXIT THE RESTROOM (18" BESIDE THE | | DOOR) FBC A 404.2.4 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-03-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-03-14 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-03-14 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-16 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-16 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-12-23 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-12-23 |
Time |
16:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-02-02 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2021-11-16 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-03-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-03-14 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-24 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-02-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-02-16 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-02-01 |
Time |
15:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2021-12-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-12-23 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-11-15 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-02-25 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-02-25 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-02-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-02-07 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-02-07 |
Time |
12:08 |
Sent To |
|
|
Notes |
2022-02-07 14:48:57 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 21110547 | | 2/7/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET EP-1: THE NEW UTILITY SINK AND KITCHEN SINK | | REQUIRE HOT WATER AT MINIMUM 110 DEGREES F, HOWEVER THE | | SPECIFIED CHRONOMITE INSTA-HOT WATER HEATER HAS AN | | INTEGRAL MIXING VALVE WHICH WILL DELIVER TEMPERED WATER | | BETWEEN 85 AND 110 DEGREES. THIS UNIT CANNOT BE USED- | | SECS. 202 AND 607.1 FBC P. | | | | 2) EP-1: SHOW THE LOCATIONS OF THE REQUIRED FULL OPEN | | SHUT OFF VALVES AND CHECK VALVES FOR THE SUMP PUMP | | DISCHARGE LINES AND VERIFY THEY WILL BE ACCESSIBLE- | | SEC. 712.2 FBC P. A) PLEASE SHOW THE DISCHARGE PIPING | | SHALL CONNECT TO THE TOP OF THE 3-INCH SANITARY LINE | | USING A WYE FITTING- SEC. 712.3.5 FBC P. | | | | 3) EP-1: PLEASE CORRECT THE NOTE SPECIFYING 5/8-INCH | | THICK INSULATION FOR HOT WATER PIPING- 1-INCH THICK IS | | REQUIRED PER TABLE C403.2.10 FBC EC. | | | | 4) A-4 & EP-1: CONCERNING THE NEW MOP SINK PLEASE SEE | | SEC. 310.3 FBC P AND SEC.1210.2.2 FBC B. WALLS AND | | PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS AND | | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | SURFACE, TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE | | FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE | | MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS | | NOT ADVERSELY AFFECTED BY MOISTURE. | | | | 5) A-4 & EP-1: THE DOOR SHALL NOT SWING INTO THE CLEAR | | FLOOR SPACE REQUIRED FOR THE LAVATORY UNLESS MEETING | | EXCEPTION 2 UNDER SEC. 603.2.3 FBC ACC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-12-03 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-12-03 |
Time |
14:31 |
Sent To |
|
|
Notes |
2021-12-03 17:03:11 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 21110547 | | 12/3/21 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS CS, A1, EP-1: REFER TO SECTION 810.1 FBC EX- | | IT APPEARS THE OCCUPANT LOAD OF THE TENANT SPACE HAS | | INCREASED BY MORE THAN 20 % WHICH REQUIRES PLUMBING | | FIXTURES TO BE PROVIDED IN QUANTITIES AS SPECIFIED IN | | THE FBC P. THE PLUMBING FIXTURE CALCULATIONS ON SHEET | | CS INDICATE WATER CLOSETS AND LAVATORIES FOR BOTH MALE | | AND FEMALE HOWEVER THE PLANS INDICATE A MALE TOILET | | ROOM ONLY. REFER TO TABLE 403.1 AND SECTION 403.2 FBC P | | AND PROVIDE A TOILET ROOM FOR FEMALE USE. PLEASE NOTE | | THAT SEPARATE FACILITIES ARE REQUIRED- REVISE THE PLANS | | ACCORDINGLY. | | | | 2) CS, A1, EP-1: REFER TO TABLE 403.1 FBC P: DRINKING | | FOUNTAINS AND SERVICE SINKS ARE REQUIRED FIXTURES FOR S | | OCCUPANCIES. PLEASE REVISE THE PLANS TO SHOW THE | | LOCATIONS OF THE FIXTURES AND PLUMBING PIPING DETAILS- | | SECTION 107.2.1 WPB. | | | | 3) SHEET A1: SHOW THE MINIMUM LENGTHS OF THE WATER | | CLOSET GRAB BARS AS THEY ARE INDICATED IN SECTION 604.5 | | & FIGURES 604.5.1 & 604.5.2 FBC ACC. | | | | 4) A1: REFER TO SECTION 606.2 AND FIGURES 306.2 & 306.3 | | FBC ACC AND SHOW THE CORRECT KNEE AND TOE CLEARANCES | | FOR THE LAVATORY. | | | | 5) A1: REFER TO SECTION 606.2 AND FIGURES 306.2 & 306.3 | | FBC ACC PLEASE PROVIDE A DETAIL DEPICTING THE KNEE AND | | TOE CLEARANCES AT THE BREAKROOM SINK- SECTION 606.2 AND | | FIGURES 306.2 & 306.3 FBC ACC. | | | | 6) EP-1: THE RISER DRAWINGS DO NOT INDICATE PIPING FOR | | THE TOILET ROOM FIXTURES- SECTION 107.2.1 WPB. | | | | 7) EP-1: INDICATE THE SOURCE OF THE HOT WATER FOR THE | | FIXTURES- SECTION 607.1 FBC P. | | | | 8) EP-1: INDICATE HOW TEMPERED WATER WILL BE DELIVERED | | FROM THE LAVATORIES- 419.5 FBC P. | | | | 9) EP-1: REFER TO SECTION & TABLE C404.5.1 FBC EC FOR | | MAXIMUM ALLOWABLE LENGTHS OF HW PIPING FROM THE HW | | SOURCE TO THE FIXTURE SUPPLY PIPE AT THE LAVATORIES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-03-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-03-02 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-03-02 |
Time |
11:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-02-14 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-02-14 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2021-12-21 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2021-12-21 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|